What the page converts

Magnetic flux density, often loosely called field strength, is measured in teslas. Weak ambient fields are commonly given in microteslas, while magnets and laboratory fields are given in milliteslas or teslas. The page converts a value from µT to mT. Your phone's magnetometer app may display 48 µT, a magnet data sheet may list 150 mT, and a report may need both in the same unit. Entering 48 returns 0.048 mT, which you can compare directly with the magnet. The converter changes the prefix of a flux density and nothing more. It does not estimate how a field varies with distance, whether a field is safe for a person or a device, or what a sensor will read in a particular location. Because the factor is exactly 0.001, you can verify any single result by eye, which makes the page a reasonable check on a longer spreadsheet column.

The tesla and the prefixes

The tesla is the SI derived unit of magnetic flux density. One tesla is one weber per square meter, which in base units is one kilogram per second squared per ampere. The unit honors Nikola Tesla. The prefixes micro and milli are exact powers of ten in the SI Brochure from the BIPM, with micro meaning 10⁻⁶ and milli meaning 10⁻³. One millitesla is therefore 1,000 microteslas, and the page formula is mT = µT × 0.001. The factor does not depend on the type of material, the frequency of the field or the direction, because only the unit scale changes. Be aware that the page works with a flux density magnitude. It does not handle vectors or components, though you can convert each component of a vector separately with the same factor.

The default of 10 µT

With the default input of 10 µT, the result is 0.01 mT. The raw output may display 0.009999999999999998 because of floating-point arithmetic, and the intended value is 0.01 mT. A conversion through teslas confirms the number: 10 µT is 0.00001 T, and 0.01 mT is also 0.00001 T. For a mental check, move the decimal point three places to the left. If your mental result is 0.0001 or 10,000, you have used the wrong factor. In gauss, the same field is 0.1 G, since one gauss equals 100 µT. The default is on the same scale as small household appliance fields, roughly speaking. The comparison is only meant for orientation, because the actual value close to a device depends on distance and design. Reading the answer aloud, ten microteslas is one hundredth of a millitesla.

The magnetic field of the Earth

Earth's magnetic field at the surface lies roughly between 25 and 65 µT, depending on location. It is weakest over South America and the South Atlantic and strongest near the magnetic poles. A common midlatitude value is around 50 µT, which equals 0.05 mT and 0.5 G. Converting 25 µT gives 0.025 mT, and 65 µT gives 0.065 mT. These are field magnitudes at the surface, and they change slowly over years as the geomagnetic field evolves. Navigation compasses respond to the horizontal component only, which is smaller than the total in most places. The NOAA and British Geological Survey models provide values for a given place and date. Treat the figures here as approximate ranges and not as a reference for any specific location. The International Geomagnetic Reference Field is the standard model that research groups use to compute these values for any date and location.

Gauss and the CGS legacy

Older literature and many handheld meters still use the gauss, a CGS unit. One gauss equals exactly 10⁻⁴ tesla, which is 100 µT or 0.1 mT. The Earth's field of about 0.5 G is therefore 50 µT. NIST Special Publication 811 lists the gauss among units that are not part of the SI and discourages its use in new work. When you meet a value in gauss, convert to teslas first and then apply the prefix. For example, 0.3 G is 30 µT, or 0.03 mT. The dropdown on this page includes gauss and milligauss, so you can choose them directly. The CGS system also has the oersted for magnetic field strength, which is a different quantity and is not interchangeable with gauss except in vacuum by a numerical coincidence of the unit system.

Smartphones and magnetometers

Phones contain a three-axis magnetometer, usually used for the compass, and many apps display the field in microteslas. A reading between 25 and 65 µT outdoors is typical. Near a laptop, speaker or metal furniture, the reading can change by tens of microteslas, which is why the compass needs calibration. If an app reports 120 µT, that is 0.12 mT, well above the Earth's field and a sign of nearby magnetic material. Sensor noise and calibration offsets can reach a few microteslas on consumer devices, so tiny differences should not be over-read. Converting to millitesla is useful when you compare the phone's measurement with a magnet's data sheet. The magnet at the surface may be hundreds of milliteslas, thousands of times larger than ambient fields. Apps that show the field as three components plus a total let you test the conversion on each axis, since the same factor applies to every component.

Milliteslas in practice

The millitesla range includes fridge magnets, small permanent magnets at a distance and many laboratory setups. A flexible fridge magnet has a surface field on the order of a few milliteslas. Strong neodymium magnets reach several hundred milliteslas at the surface, and can exceed 1 T in the gap of a magnetic circuit. Medical imaging magnets are specified in teslas, with 1.5 T and 3 T common, which are 1,500 mT and 3,000 mT. A convenient scale is that 1 mT equals 1,000 µT, so a fridge magnet at 5 mT is 5,000 µT, about a hundred times Earth's field. These values are approximate and vary widely between products. The converter helps move among these scales without mistakes in the exponent, but it does not predict how a specific magnet behaves. Loudspeaker drivers rely on gap fields of the order of a tesla, which is why a small speaker magnet can pull strongly on nearby steel.

Flux density and field strength

Flux density B, in teslas, and magnetic field strength H, in amperes per meter, are different quantities. In vacuum and approximately in air, B equals the permeability of free space, about 1.2566 × 10⁻⁶ T·m/A, times H. A field strength of 1 A/m therefore corresponds to a flux density of about 1.2566 µT. In magnetic materials the relationship includes the relative permeability and, for ferromagnets, the history of the material. This page converts only the flux density in its different prefixes. Do not apply it to values in A/m or oersteds without first converting them with the relevant relation. Many product data sheets say magnetic field when they mean flux density, so check the unit printed beside the number before choosing the converter. Flux density in teslas also equals magnetic flux in webers divided by area in square meters, which is why the tesla is called a weber per square meter.

A second worked example

Consider a measurement of 5,000 µT near a small magnet. Multiplying by 0.001 gives 5 mT. Next, a field of 65 µT at a high latitude site becomes 0.065 mT. A third example uses 50 µT, a typical mid-latitude value, which becomes 0.05 mT. The reverse works the same way: a millitesla value such as 0.2 mT is 200 µT. When a measurement is the magnitude of a vector, combine the components first. A field of 30 µT along x and 40 µT along y has a magnitude of 50 µT, by the Pythagorean rule, and converts to 0.05 mT. Convert at the end, after combining, and the result is the same as converting each component first. The numbers here are illustrative and not tied to a particular site. If a source gives the field in nanoteslas, divide by 1,000 first to reach microteslas, then apply this page.

Peak, RMS and alternating fields

A field may be static or time-varying, and the number you enter should match the type of measure on your source. For alternating fields such as the 50 or 60 Hz fields near power equipment, measurements are often given as RMS, while peak values are larger by a factor of about 1.414 for a sinusoid. Converting the prefix does not change the type of measure, so a value in RMS microteslas converts to RMS milliteslas. Do not mix an RMS value from one source with a peak value from another when making a comparison. For static fields, the issue does not arise. Some instruments also report the maximum of the three axes rather than the vector magnitude, and the two can differ by up to a factor of about 1.7. Always read the instrument manual to see which measure is shown, and record it next to the converted number.

Scope of the converter

The page changes the prefix of a flux density value and does not calculate installation limits, equipment ratings, protection, material response or compliance. It does not say whether a field is acceptable for a person, a pacemaker, a sensor or a piece of equipment. Exposure limits and device immunity requirements come from standards and manufacturers, and they require the measurement conditions to be known. For definitions of the tesla and its prefixes, see the BIPM SI Brochure and NIST Special Publication 811. Use the converter to avoid decimal errors and keep the original unit alongside each value for traceability. The factor is exact, so any difference between this page and another source almost always comes from a different input unit or a different definition of the quantity.