From CGS magnet data to SI
Permanent magnets, loudspeakers, motors and older instruments often list field strength in gauss, while SI-based textbooks, simulation software and most current standards use teslas. This page connects the two. It multiplies by 0.0001, a factor that comes straight from the definition of the CGS electromagnetic unit. The values involved span a huge range: a refrigerator magnet delivers something like 50 G at its surface, a strong neodymium magnet several thousand gauss, and a clinical MRI scanner 15,000 to 30,000 G. In teslas those are 0.005 T, a few tenths of a tesla, and 1.5 to 3 T, which are the numbers radiologists use. The converter changes the label and leaves the physics alone.
Definition and history of the two units
The tesla is the SI derived unit of magnetic flux density, one weber per square meter, which equals one kilogram per ampere per second squared. It was named for Nikola Tesla and adopted by the General Conference on Weights and Measures in 1960. The gauss comes from the CGS electromagnetic system and equals one maxwell per square centimeter. NIST SP 811 gives the relation 1 G = 10^-4 T, and the BIPM SI Brochure does not include the gauss among accepted non-SI units. Because the relation is exact, the factor 0.0001 carries no uncertainty. Any imprecision in the result comes from the value you typed.
Reading the default of 10 G
The default of 10 G returns 0.001 T, one millitesla. A useful memory aid is that 10,000 G equals 1 T, so 10 G is one thousandth of a tesla. Typing 1 gives 0.0001 T, and typing 50 gives 0.005 T. The default is a weak field compared with magnet data sheets, but it is close to what you might measure a centimeter or two from a small ferrite magnet. If you see a result that is larger than the input, then the selectors have been swapped: a tesla figure for the same field is always numerically much smaller than the gauss figure.
Magnet specifications in teslas
Datasheets for permanent magnets give surface field or residual flux density, labeled Br. A grade of sintered neodymium magnet may list Br near 1.2 to 1.4 T, which is 12,000 to 14,000 G. Ferrite magnets sit lower, around 0.2 to 0.4 T or 2,000 to 4,000 G. Surface field measured at the face of a real magnet is lower than Br and depends on shape. The converter maps each of these as 5,000 G to 0.5 T, 1,000 G to 0.1 T, and so on. When designing a sensor or motor in SI-based software, enter flux density in teslas, and use this page to translate the gauss figure from the supplier. As an illustration, a data sheet that lists 3,200 G at the pole face converts to 0.32 T, and a loudspeaker gap field of 9,000 G converts to 0.9 T. The values are examples of the arithmetic only. Check the measurement point on the supplier sheet, because surface, gap and residual values describe different things even when all are written in gauss.
MRI and laboratory fields
Medical and research magnets are always quoted in teslas, but literature on small experiments uses gauss. A 1.5 T scanner has a main field of 15,000 G and a 3 T scanner has 30,000 G, which is roughly 30,000 to 60,000 times the Earth field of 0.25 to 0.65 G. The page shows these relations directly: enter 15,000 G and read 1.5 T. Laboratory electromagnets that reach 1 T are at 10,000 G. Tesla values far above 10 T need superconducting coils, while pulsed facilities reach much higher fields briefly. The unit conversion tells you nothing about hazards, and facilities have their own safety rules.
Converting teslas back to gauss
Select T as the source and G as the target to multiply by 10,000. A field of 0.005 T is 50 G, 0.05 T is 500 G, and 7 T, the strength of some research scanners, is 70,000 G. A field of 0.0002 T equals 2 G, and 0.32 T equals 3,200 G. This direction helps when an SI-based paper states a field and your sensor or gauss meter reads in gauss. Round the converted figure to the resolution of the instrument, because a hand-held meter showing 49.7 G does not support a result written as 49.7000 G.
Rounding, instruments and direction
A gauss meter or Hall probe reports one component of the field along the probe axis, and the reading depends on orientation and distance. Results can vary by several percent with small movements, and handheld meters often have accuracy of a few percent of reading. Converting a value to teslas changes none of that. For a report, write the field with two or three significant figures, state the measurement distance and the probe orientation, and use the page to present the same number in SI. When the tesla value will be used in a formula such as force on a charge, carry all digits through the calculation and round only the final result.
Planning a conversion across a mixed table
When a document mixes sources, convert everything to teslas once and keep the original column beside it. Take a motor design that lists a ferrite magnet at 3,800 G, a neodymium magnet at 12,500 G and an air-gap target of 0.8 T. In SI the first two are 0.38 T and 1.25 T, and the target needs no change, so all three can be compared directly. The air gap is about two thirds of the neodymium residual value, which is normal because gap flux density is lower than the magnet residual value. Sorting the column after conversion makes outliers obvious. A value that stays tiny after conversion probably came from a source that was already in teslas and was converted a second time.