A gaussmeter reading meets an SI datasheet
The usual reason to open this page is a mismatch between instruments and documents. A handheld gaussmeter, an older magnet supplier or a hobby forum quotes a field in gauss, while the sensor datasheet, the safety standard or the paper you are reading uses millitesla. The two units describe the same quantity, magnetic flux density, which physicists write as B. Only the size of the unit differs. The converter takes your number, applies the exact factor between the two units and returns the value in milliteslas. It does not look at where the field was measured, how strong a magnet is at some distance or whether a device is safe near it. It answers one narrow question: what is this reading when expressed in mT. Because the factor is a pure power of ten, the conversion never loses information. The digits stay the same and only the decimal point moves one place.
The factor and the default example
The relationship comes straight from the definition of the units. One gauss is exactly 0.0001 tesla, and one millitesla is 0.001 tesla. Dividing one by the other gives 1 G = 0.1 mT, so the formula on this page is mT = G × 0.1. The default input of 10 G therefore returns 1 mT. Going the other way, 1 mT equals 10 G, and 1 T equals 10,000 G. A quick mental check is to shift the decimal point one place to the left when going from gauss to millitesla. A reading of 250 G becomes 25 mT, and a reading of 0.8 G becomes 0.08 mT. If you ever get a result larger than your input, the units were probably chosen in the wrong order, because the millitesla is the bigger unit and the number in front of it must be smaller.
Where the gauss came from
The gauss belongs to the centimeter-gram-second system of units, in the electromagnetic variant, which dominated physics and electrical engineering before the SI took over. It is named for Carl Friedrich Gauss, who did early quantitative work on the geomagnetic field. In CGS terms, one gauss is one maxwell of magnetic flux per square centimeter. The SI tesla replaced it in formal work after the General Conference on Weights and Measures adopted the tesla in 1960, and the SI Brochure published by the BIPM lists the tesla as the coherent unit of magnetic flux density. NIST SP 811 treats the gauss as a CGS unit that is not part of the SI and gives its conversion to the tesla. The gauss survives in practice because magnet makers, gaussmeters, audio engineers and many laboratories kept their habits, and because values in the hundreds or thousands of gauss are convenient to say aloud.
Typical magnitudes in gauss and millitesla
Having a few reference points makes it easy to sanity check a conversion. The Earth's magnetic field at the surface is roughly 0.25 to 0.65 G depending on location, which is 25 to 65 microtesla or 0.025 to 0.065 mT. A small decorative refrigerator magnet may show something on the order of tens to a couple of hundred gauss at its surface, so a few millitesla to roughly twenty. A common ferrite loudspeaker magnet produces a few thousand gauss in the gap, which is a few hundred millitesla (3,000 G is 300 mT). Sintered neodymium magnets can exceed 1 T at the pole face, above 10,000 G. Clinical MRI scanners operate at 1.5 T or 3 T, which is 15,000 or 30,000 G. All of these values are indicative ranges. The actual field of any magnet depends on its grade, geometry and the distance from the probe.
A second worked conversion
Suppose a hobbyist measures the field at the surface of a small ceramic magnet and reads 1,500 G. Dividing by 10 gives 150 mT, which is the same as 0.15 T. A datasheet for a Hall sensor might say the sensor saturates at 100 mT, and the conversion shows right away that this magnet is above that limit at the surface, since 150 mT is 1,500 G. Moving the sensor away until the reading falls to 600 G corresponds to 60 mT, comfortably inside the range. The same arithmetic applies to the weak end. A compass-grade reading of 0.5 G is 0.05 mT, or 50 microtesla, which is close to a typical geomagnetic field. These numbers are illustrative, but they show how the conversion helps you compare a measurement against a stated limit without any extra tools.
Sensitivity figures on Hall-effect sensors
Linear Hall-effect sensors are often specified with a sensitivity such as 2.5 mV/G or 5 mV/G. That slope is a rate, volts per unit of flux density, so converting it follows the opposite direction from converting a field value. One gauss is 0.1 mT, so a sensor with 5 mV/G responds with 50 mV for every millitesla. The conversion rule for the field value is to divide by 10 for gauss to millitesla, and the rule for the slope is to multiply by 10 for per gauss to per millitesla. Keeping that straight prevents a common ten-fold error when moving a design from a gauss-based datasheet to a millitesla-based specification. Also check the quiescent output, the voltage at zero field, since the reading you convert is the change from that baseline and not the absolute output of the sensor.
Gauss, milligauss and microtesla side by side
Environmental and power-frequency measurements often use milligauss, and that is a frequent source of confusion next to the millitesla. One milligauss is 0.001 G, which is 0.0001 mT, or 0.1 microtesla. A household reading of 2 mG near an appliance is therefore 0.2 microtesla, a tiny fraction of a millitesla. The converter lists milligauss as one of its units, so you can convert it directly. The practical danger is mixing the prefixes: a millitesla is ten thousand times larger than a milligauss and ten times larger than a gauss. Written out, 1 mT is 10 G and 10,000 mG. If a reading looks absurd by a factor of 10,000, check whether someone swapped milligauss for gauss, or milli for micro. Reporting both units in a lab notebook, for example 3.2 mT (32 G), makes later checking easier.
Flux density is not the same as field strength
Magnetic flux density B and magnetic field strength H are different quantities, and the CGS system adds to the confusion. The gauss measures B. The CGS unit for H is the oersted, and in vacuum a field of 1 Oe corresponds to a flux density of 1 G, which leads many people to treat the units as interchangeable. In SI, B is in tesla and H is in amperes per meter, and 1 oersted equals 1000/(4π) A/m, about 79.577 A/m. Inside magnetic materials, B and H differ by the material response, so B in gauss does not equal H in oersteds. This page converts B between gauss and tesla multiples only. If a datasheet gives coercivity in oersteds or kA/m, use a unit converter for magnetic field strength instead, because multiplying that figure by 0.1 would give a meaningless answer.
Measurement practice and rounding
The conversion is exact, but the reading it starts from is not. A gaussmeter probe measures the component of the field along its sensing axis, so tilting the probe changes the number. Readings change quickly with distance near a magnet, so a few tenths of a millimeter of probe standoff can matter. Hall probes also drift with temperature, and consumer meters often specify accuracy of several percent of reading. When you convert, keep the same number of significant figures as the original measurement. A reading of 1,480 G with a 3 percent uncertainty is better reported as about 148 mT than as 148.0000 mT. Because the factor is 0.1, no rounding enters the conversion, so any imprecision in the result comes from the instrument and the placement of the probe.
What the converter leaves out
This page restates one flux density in different units. It does not calculate the field of a magnet at a distance, convert between flux density and magnetic flux, or decide whether a field is acceptable near implants, credit cards, compasses or sensitive electronics. Safety thresholds, such as the 5 gauss line that MRI facilities use to mark controlled areas, are set by site planning guidance and manufacturers, and the 5 G figure corresponds to 0.5 mT only as a unit conversion. Equipment ratings, shielding performance, regulatory limits and material response are outside the scope of the calculation. If a decision depends on any of these, rely on the relevant standard or manufacturer documentation and use this page only to put a number into the unit that document expects.
Audio and motor magnets
Loudspeaker and motor designers still quote air-gap fields in gauss, so a driver specification might list 9,000 G in the gap while a finite-element tool wants tesla or millitesla. The converter gives 900 mT for that figure, which is 0.9 T. A second case is a small brushed motor with ceramic magnets reading about 2,000 G at the pole face, equal to 200 mT. When you compare designs, convert every field to the same unit first, because mixed units hide the fact that one magnet is roughly four and a half times stronger than another. The values in this paragraph are illustrative, not data for particular products. Real gap fields vary along the gap and with temperature, so quote the position of the probe and the temperature alongside the converted number whenever you record a measurement for later comparison.
Converting a list of readings
Often the job is a table, not a single value. Suppose a line scan across a magnet gives 120, 480, 950 and 1,300 G at four positions. Each reading is divided by 10, giving 12, 48, 95 and 130 mT. The ratios between readings stay unchanged, so the shape of the scan looks identical in either unit, only the axis labels change. Spreadsheet users can apply the factor 0.1 down a column and keep the original column beside it for traceability. If the instrument records in milligauss at the low end of its range, use the milligauss entry in the unit menu instead of doing two conversions in your head. Check one value by hand, such as 950 G giving 95 mT, to confirm the whole column is right.