Who reads fields in milligauss
Milligauss is the working unit of many low-frequency field meters, especially in the United States, where readings of household wiring, appliances, power lines and electronic equipment are traditionally given in mG. A reference table may list a larger source in gauss, such as a speaker magnet or a lab magnet, while the meter that you hold shows mG. Converting between the two lets you place the readings on one scale. The page makes a single prefix change of a factor of 1,000, and it is intended for people comparing documents, not for evaluating exposure. It does not say whether a reading is high, low, safe or compliant, and it contains no limits.
The prefix and the CGS definition
The gauss is the CGS electromagnetic unit of magnetic flux density, equal to one maxwell per square centimeter. In SI terms, 1 G = 0.0001 T exactly. The milli prefix then divides the unit by a thousand, so 1 mG = 0.001 G = 0.1 microtesla = 100 nanotesla. The SI Brochure does not list the gauss, but NIST SP 811 documents it and its tesla equivalent. The gauss is named after Carl Friedrich Gauss, whose work on terrestrial magnetism led to some of the first systematic measurements of the Earth field. The milligauss is just the practical sub-unit that matches the size of weak ambient fields.
The default of 10 G
The page opens at 10 G and returns 10,000 mG. A field of 10 G is 1 millitesla, which is stronger than a typical background but small beside the surface field of a strong permanent magnet. Because the factor is a pure power of ten, the result is easy to verify: add three zeros, or move the decimal three places right. Typing 0.5 gives 500 mG, and 2.5 gives 2,500 mG. A value that comes out with the decimal in the wrong direction suggests that the source and target units have been reversed, since milligauss numbers should always be larger than the gauss number for the same field. In SI terms the default is also easy to state: 10,000 mG is 1,000 microtesla, or one millitesla, which is the figure a lab report in SI would use for the same field.
The Earth field on the milligauss scale
The geomagnetic field at the surface runs from about 0.25 to 0.65 gauss depending on location, which is 250 to 650 mG. At a mid-latitude site a typical value near 0.5 G corresponds to 500 mG, or 50 microtesla. This is a convenient reference when you read a meter indoors. A meter showing a few hundred mG of static field is probably sensing the Earth field plus the steel in the building, and a reading is only meaningful if you know whether the instrument is built for static or for alternating fields. Many low-cost EMF meters are designed for 50 and 60 Hz fields and do not report the static field in the same way.
Household readings as an illustration
Power-frequency field readings are often reported as a few mG in a room and higher close to appliances, so the unit gives manageable numbers. As an illustration, a field of 3.5 mG is 0.0035 G, or 0.35 microtesla. A reading of 50 mG is 0.05 G and 5 microtesla. The numbers in this paragraph are examples to show the conversion, and the page contains no data about any specific device, building or standard. If you need guideline values for exposure, take them from the named authority, such as the ICNIRP guidelines or national occupational rules, and check which unit the document uses before comparing.
From milligauss back to gauss
Choosing mG as the source unit and G as the target divides by 1,000. A reading of 100 mG is 0.1 G, 4 mG is 0.004 G, and 1 mG is 0.001 G. This direction is useful when a meter report must be compared with a table that lists fields in gauss, or when a magnet specification in gauss is compared to ambient values. The result is always smaller than the starting number. If a long list of milligauss readings is converted at once, keep them in a spreadsheet column with the unit in the header and apply the same divisor to the whole column.
Gauss, milligauss and oersted
In CGS, the gauss measures magnetic flux density B, and the oersted measures magnetic field strength H. In vacuum or air they are numerically the same, so a field of 1 Oe corresponds to 1 G, which sometimes leads people to treat the two as interchangeable. In a magnetic material, however, B and H differ, and the unit label tells you which one the source quotes. The converter only handles the flux density. It cannot turn oersted into gauss for a material with permeability different from one, and it does not accept A/m. Check the label of your source before converting to avoid carrying that error forward. A field of 250 Oe in air corresponds to 250 G or 250,000 mG, and that equivalence stops at the surface of any magnetic material.
Meter resolution and digits
The conversion is exact, but the precision of the answer comes from the reading. A basic gauss meter may resolve 0.1 mG, while a lab magnetometer may resolve a microgauss or less. A reading of 0.0035 G is only meaningful to two digits if the instrument has a resolution of 0.0001 G, which is 0.1 mG. Report the converted value with the same number of significant digits as the source. For averages over several readings, convert after averaging, not before, to avoid mixing roundings. Keep a note of the instrument, its frequency response and the orientation of the probe, since a single-axis probe reads only one component of the field.
Confusions to avoid
Several look-alike symbols cause trouble. A capital G is gauss, while a lowercase g is gram or standard gravity, and G in physics also names the gravitational constant. Milligauss, with a capital G inside mG, should not be mixed with the milli-g of acceleration. The tesla is 10,000 times larger than the gauss, so 1 mT is 10 G and 10,000 mG. The microtesla used by many European and scientific sources is 10 mG. Confirm which unit the table uses before the conversion, and write the unit with every number.