Why microwebers suit small fluxes
The weber is a large unit for the fluxes met in small devices. A fridge magnet or a search coil in a laboratory deals with flux measured in millionths of a weber, which is exactly where the microweber sits. Older instruments and papers, however, report the same flux in maxwells, the CGS unit. This page connects the two. You enter a value in maxwells and the converter returns microwebers using the exact factor 0.01. The result describes the same total magnetic flux through a surface, just written in the SI prefix that keeps numbers readable. It does not tell you how strong the field is at a point, since that is flux density, and it does not say anything about the magnet or coil that produced the flux. Think of it as a translation between two ways of writing the same amount of flux, chosen so that a result like 0.1 µWb is easy to read and compare.
The factor behind the default
One maxwell is defined as 10 to the minus 8 weber. A microweber is 10 to the minus 6 weber, so one maxwell is 10 to the minus 2 microweber, or 0.01 µWb. The formula on the page is therefore µWb = Mx × 0.01, and the default entry of 10 Mx gives 0.1 µWb. In reverse, 1 µWb equals 100 Mx. This is a hundredfold relationship, so converting from maxwells moves the decimal point two places to the left, and converting from microwebers to maxwells moves it two places to the right. That small shift makes the conversion easy to check by eye. A value of 5,000 Mx becomes 50 µWb, and a value of 12 Mx becomes 0.12 µWb. If your result is larger than your input, the direction is wrong, because the microweber is the bigger unit.
What a maxwell is
The maxwell is the CGS electromagnetic unit of magnetic flux, named for James Clerk Maxwell. It is defined as one gauss times one square centimeter. Because 1 G is 10 to the minus 4 tesla and 1 cm² is 10 to the minus 4 square meter, the product is 10 to the minus 8 tesla square meter, which is 10 to the minus 8 weber, since 1 Wb = 1 T·m². NIST SP 811 lists the maxwell among CGS units that are outside the SI and gives its relationship to the weber. Older engineering literature also calls one maxwell a line of flux, and a kiloline is 1,000 maxwells. Ten microwebers therefore equal one kiloline. The CGS term persisted in electrical machine design and in loudspeaker and magnet catalogs for decades, which is why datasheets older than a generation often quote totals in maxwells or kilolines.
Kilolines and magnet totals
Magnet suppliers and old design handbooks often quote total flux from a pole in kilolines or maxwells because those numbers were convenient in CGS. A figure of 1 kiloline is 1,000 Mx, which converts to 10 µWb with this page. A value of 250,000 Mx, sometimes written as 250 kilolines, equals 2,500 µWb, or 2.5 mWb. The converter handles any of these through the single factor, so you can enter the number of maxwells directly. When reading old catalogs, check whether the quoted flux is leakage, total or useful gap flux, since the maxwell figure alone does not say which one it is. Also note that a measurement taken with a coil and a fluxmeter reports the flux linked by that coil, so the turns count matters when converting to flux linkage. The unit conversion itself, from maxwells to microwebers, is unaffected by these details.
A worked example with a search coil
Imagine a pickup coil of 50 turns wrapped around a small magnet, connected to an integrating fluxmeter. When the magnet is pulled out of the coil, the meter reads a total change of 1,200 Mx per turn. Converting with the page gives 1,200 × 0.01, which is 12 µWb per turn. Multiplying by the 50 turns gives a flux linkage of 600 µWb-turns, but the per-turn flux is the number that describes the magnet. If the same pull took 0.5 seconds with a constant rate of change, the average induced voltage in the coil would be 50 × 12 µWb / 0.5 s, which is 1.2 millivolts. These values are illustrative and the arithmetic is simple, yet they show why microwebers are convenient: voltage in volts equals flux in webers per second, so a flux in µWb divided by a time in seconds gives a voltage in microvolts directly.
Using the weber to find induced voltage
Faraday's law links flux to voltage. The average electromotive force in a coil equals the number of turns times the change in flux divided by the time taken. Since one weber per second is one volt, working in microwebers lets you read the result in microvolts without conversion. With the default 10 Mx, which is 0.1 µWb, a change over one second in a single-turn coil would induce 0.1 µV, far below what ordinary meters resolve. Increasing the change to 5,000 Mx gives 50 µWb, and a 100-turn coil changing it in 0.1 s produces 100 × 50 µWb / 0.1 s, which is 50 mV. These examples are not measurements, but they show the size of flux that produces usable voltages. The conversion from maxwells matters whenever a legacy specification gives flux in CGS while your instrument or simulation tool works in SI.
Relating flux to flux density and area
Total flux and flux density are related by area. For a uniform field perpendicular to a surface, flux equals flux density times area. A field of 10 G through an area of 1 cm² is exactly 10 Mx, which converts to 0.1 µWb, matching the default example. In SI terms, 1 mT through 1 cm² is 10 to the minus 3 tesla times 10 to the minus 4 square meter, which is 0.1 µWb again, confirming that 10 G equals 1 mT. This relationship lets you cross-check numbers from two different instruments. If a gaussmeter gives 800 G over a pole face of 2 cm², the flux is 1,600 Mx, or 16 µWb. Uniformity is an assumption, and real magnets have fields that vary across the face, so the product is an estimate unless you measure the whole distribution or integrate with a coil.
Prefix pitfalls to avoid
The micro prefix is easy to confuse with milli, and the error costs a factor of one thousand. One microweber is 0.001 milliweber, and one maxwell is 0.00001 milliweber. The converter lists webers, milliwebers, microwebers, nanowebers, picowebers and maxwells, so you can cross-check by converting to another prefix and back. Another trap is the lowercase and uppercase distinction in symbols, where Mx is the maxwell and mWb is the milliweber, and the letter M alone would suggest mega in SI. A third trap is mixing flux and flux density: a result in µWb should be compared with other fluxes, and a result in mT with other flux densities. A printed table that lists maxwells per square centimeter is actually flux density in gauss, so use the gauss converter for that, not this one.
Where the conversion stops
The page converts a flux value between units and nothing more. It does not compute the flux of a particular magnet or coil, estimate losses in a core, predict saturation or check any rating or compliance requirement. The assumption is that the input is a known magnetic flux and the output is the same flux in a compatible unit. Rounding in the result comes from the floating-point display, not from the physics, because the factor 0.01 is exact. For work that supports a design decision, take flux values from the manufacturer's data, a calibrated fluxmeter or the relevant standard, and use this page only to put them in the units your calculations use. Where a report needs both units, quote the original CGS number and the SI value together so reviewers can trace the conversion.
Reading old magnet and relay notes
Mid-century handbooks on relays, polarized magnets and loudspeakers often give fluxes of a few thousand to a few hundred thousand maxwells. A relay note might quote 6,000 Mx of useful gap flux, which the page converts to 60 µWb. A loudspeaker pole piece quoted at 120,000 Mx becomes 1,200 µWb, or 1.2 mWb. Those values are invented for demonstration, but they fall in the range such sources used. Having them in microwebers lets you compare directly with modern fluxmeter readings and finite-element results. If a note gives flux density in gauss and an area in square centimeters, multiply them first to get maxwells, then convert, as in the earlier example of 1,600 Mx from 800 G over 2 cm².
Checking a conversion by two routes
A reliable habit is to convert twice by different paths. Take 3,750 Mx. Direct conversion gives 3,750 × 0.01, which is 37.5 µWb. Alternatively, convert to webers first, 3,750 × 1e-8 = 3.75e-5 Wb, then multiply by one million to reach microwebers, which gives 37.5 µWb again. If the two routes disagree, a prefix has slipped. You can also use kilolines as an intermediate: 3.75 kilolines times 10 µWb per kiloline gives 37.5 µWb. Agreement across all three routes is strong evidence that the entry and the unit menus are right. This takes seconds and avoids carrying a power-of-ten error into a later calculation where it is harder to spot.