Why flux calculations want webers
Most formulas for coils, transformers and motors assume base SI units. The induced voltage in a winding, for example, is the number of turns times the change in flux in webers divided by the time in seconds. If a datasheet or a measurement gives flux in milliwebers, you convert to webers before you plug the number into that formula, or the voltage comes out a thousand times too large. This page does that division. Enter the milliweber value and read the weber value, or flip the units to go the other way. It suits students, technicians and engineers who move between a fluxmeter display, a manufacturer table and a hand calculation, and it removes the one step where a decimal point is easy to misplace.
What a weber is
The weber is the SI unit of magnetic flux. One weber is the flux that, linking a circuit of one turn, produces an electromotive force of one volt when it is reduced to zero at a uniform rate in one second. That makes it a volt-second. It is also a tesla times a square meter. The BIPM SI Brochure lists the weber among the named derived units, and NIST SP 811 gives its definition and relation to the CGS maxwell. A milliweber is one thousandth of that. The formula is Wb = mWb × 0.001, and the factor is exact because it comes from the prefix definition and not from a measurement.
Three decimal places, in both directions
The page begins with 10 mWb and returns 0.01 Wb. Other values show the same shift of three places. A flux of 250 mWb is 0.25 Wb, 0.8 mWb is 0.0008 Wb and 3 mWb is 0.003 Wb. In the other direction, 0.045 Wb is 45 mWb, and 1.2 Wb is 1,200 mWb. A milliweber is a convenient size for small magnets and small cores, and a weber suits large machines such as generators and big transformers. If the page returns a number larger than your input, check that the From unit is milliwebers, since entering webers in that field would multiply by a thousand instead.
Flux from field and area
Flux through a surface equals the average flux density times the area, when the field is perpendicular to the surface. A core with a cross section of 25 cm², which is 0.0025 m², carrying 1.2 T has a flux of 1.2 × 0.0025 = 0.003 Wb, or 3 mWb. A smaller core of 4 cm², or 0.0004 m², at 1.5 T carries 0.0006 Wb, which is 0.6 mWb. The calculation is done in tesla and square meters, so webers come out directly, and you convert to milliwebers for display. The page performs the unit change on a value you already have. The multiplication of field and area is yours to do, or to take from a design table.
Transformer and motor design numbers
A transformer winding follows the relation that the RMS voltage is about 4.44 times the frequency times the number of turns times the peak flux. At 50 Hz with a peak flux of 3 mWb, which is 0.003 Wb, a 100-turn winding gives about 4.44 × 50 × 100 × 0.003 = 66.6 V. The same flux entered as 3 by mistake would give a nonsense answer in the thousands of volts. Motor designers use similar relations for back electromotive force. The factor 4.44 applies to sinusoidal waveforms, and it comes from the form factor and two pi. The page does not compute voltage. It supplies the weber value that such formulas need.
Reading fluxmeters and magnet data
A fluxmeter that integrates the voltage from a search coil may show its result in milliwebers, and a magnet manufacturer may list flux in the same unit for a defined pole face. If the data is for a small magnet with 0.4 mWb, the weber value is 0.0004 Wb. A larger holding magnet of 0.12 Wb is 120 mWb. Check the test conditions beside the number, such as the gap or the keeper used, because flux through a magnet depends on the magnetic circuit around it. Two parts with the same material can show different flux in different test setups. The converter only changes the prefix and not the conditions.
Reverse conversion and sanity checks
To go from webers to milliwebers, set Wb as the source and mWb as the target. The page multiplies by 1,000. Flux values are often small in webers, such as 0.0004 Wb, and it is easier to read 0.4 mWb. A good sanity check uses the volt-second meaning: a flux change of 0.01 Wb in 0.5 s in a single turn gives an average voltage of 0.02 V, and the same change in 10 ms gives 1 V. If your voltage estimate differs from the measured value by a factor of 1,000, a prefix slip between milliwebers and webers is a likely cause. Check the units of every input before you check anything else.
Flux, flux linkage and flux density
Three related quantities are easy to mix up. Flux, in webers, is the total field through a surface. Flux linkage is the flux multiplied by the number of turns that it links, and it also has the unit weber (or weber-turn). Flux density, in tesla, is flux per area. A coil of 200 turns linking 2 mWb has a flux linkage of 0.4 Wb-turns. A field of 0.5 T is not a flux until you know the area. Writing the quantity name next to every number helps avoid mistakes, because the page treats whatever you type as flux. Use it only for flux, and not for tesla or gauss values.
What the conversion does not do
The page converts a flux value from milliwebers to webers. It does not calculate saturation, losses, magnet strength, induced voltage or the suitability of a core. Material properties depend on temperature and the shape of the magnetic path, and the data sheet or the standard for your component explains the limits. For design work, follow the manufacturer curves and the codes that apply to the equipment, and have a qualified person review safety-related work. Use the converter to keep the numbers in the same units while you work through those documents, and note the prefix beside every flux you copy.