Old catalog, new design spreadsheet

Most people reach this page because a vintage loudspeaker data sheet, a magnet table or a university handout gives total flux in maxwells, while the design work in front of them uses milliwebers. The two units are tied by a fixed relationship: 1 Mx = 1e-8 Wb, so 1 Mx = 0.00001 mWb. The default input of 10 Mx returns 0.0001 mWb. A value in maxwells is usually large in the CGS documents, often tens of thousands or more, which is why kilomaxwells appear there. In milliwebers, those same values are small numbers with one or two digits before the decimal point. That difference in scale is the reason a direct, unrounded conversion is worth having. A reader who sees 36,000 Mx and 0.36 mWb side by side in a comparison table can verify the match in a second, while a reader who sees 36,000 Mx next to 3.6e-4 Wb has to count powers of ten. Choosing the milli prefix keeps tables readable, and it matches how magnetics datasheets print core and magnet flux today. If you later need nanowebers for a small coil, the maxwell converters for those prefixes sit alongside this one.

The division by 100,000

To convert, divide the maxwell count by 100,000. Moving the decimal point five places to the left does the same job by hand. So 100,000 Mx is 1 mWb, 4,500 Mx is 0.045 mWb, and 36,000 Mx is 0.36 mWb. A kilomaxwell, written kMx, is 1,000 Mx, which is 0.01 mWb. The page also accepts the reverse direction. Setting From to milliwebers and To to maxwells multiplies by 100,000, so 2.2 mWb is 220,000 Mx and 0.0125 mWb is 1,250 Mx.

Loudspeaker and magnet-assembly data

Total flux in the gap of a speaker magnet assembly was often quoted in maxwells or kilomaxwells in older literature, with flux density in gauss next to it. If a sheet gives a gap flux of 36,000 Mx, the equivalent is 0.36 mWb. A comparison with a modern magnet-structure simulation, which reports in webers or milliwebers, then becomes direct. The conversion makes the numbers comparable but says nothing about whether the two sources define the measurement location the same way. Check whether each figure is the gap flux, the magnet pole flux or a flux at some other plane. A repair technician matching a replacement magnet to an original part faces the same question. A sheet that lists 36,000 Mx for the original and a new part rated 0.30 mWb are different by about 17 percent once both are in milliwebers, and that gap is easy to see only after the conversion.

Fluxmeter readings in a teaching lab

Lab courses that use an analog fluxmeter or an integrator may provide a scale in maxwells or kilomaxwells printed on the dial or in the manual. A reading of 4,500 Mx converts to 0.045 mWb, which is the value to use if the report asks for SI units. Pair it with the number of turns in the search coil to find flux density from the area. The converter gives you the SI number, and the rest of the calculation uses your measured coil area and turns. Report the result with the same number of significant digits as the dial reading, usually two or three.

Why not go straight to webers?

Webers are the base SI unit, but the figures from maxwell sources are tiny in webers. A value of 36,000 Mx is 0.00036 Wb, a number with several leading zeros that is easy to mistype. Milliwebers shift the decimal and match the scale that magnetics datasheets use for cores and magnets, so the answer reads as 0.36 mWb. This page therefore targets milliwebers by default. For other scales, such as nanowebers or picowebers, use the matching maxwell converter on this site or the general magnetic flux converter.

Lab write-ups that need both unit systems

Students are often asked to report a measured flux in SI and then compare it with a CGS reference. Say a coil and integrator experiment gives 0.045 mWb. In maxwells that is 4,500 Mx, and with the coil area in square centimeters the same figure gives the average flux density in gauss, since one maxwell per square centimeter is one gauss. A coil face of 9 cm² then corresponds to 500 G. That last step is outside this page, which only changes the flux unit, but the conversion here is what makes the comparison possible. Write both values in the report, state the area used, and mark which one is the measured value and which is the converted one.

Checking by hand

Two quick checks catch most mistakes. First, count the decimal places. Going from maxwells to milliwebers always moves the decimal point five places to the left, so the milliweber number is always much smaller than the maxwell number. Second, run the reverse conversion. Take 0.36 mWb, convert it back and expect 36,000 Mx. A third check uses the kilomaxwell. Because 1 kMx is 0.01 mWb, a reading of 12 kMx must come out at 0.12 mWb, and 7.5 kMx at 0.075 mWb, so you can verify an entry without using the page at all. If the round trip does not return your starting number, one of the entries was mistyped. The default example, 10 Mx giving 0.0001 mWb, is a convenient sanity check for the page itself.

CGS conventions behind the maxwell

The maxwell belongs to the CGS electromagnetic system of units, where it equals one gauss times one square centimeter. In the SI, one gauss is 0.0001 T and one square centimeter is 0.0001 m², and their product is 1e-8 Wb, which agrees with the factor used here. The unit is no longer part of the SI. NIST SP 811 lists the conversion, and it is still found in magnet catalogs, older textbooks and some instrument manuals.

Rounded flux figures in milliwebers

The conversion changes the unit label on a flux value. It does not compute flux from field and area, induced voltage, saturation or losses, and it does not check ratings or compliance with any standard. The result is only as reliable as the number you enter. If the source quotes a rounded flux, such as 36,000 Mx, the milliweber answer of 0.36 inherits that rounding, and showing more digits would imply precision the source did not have. The page also returns floating-point output such as 0.0001 for the default, so a trailing digit that looks odd on screen is only the machine representation of that same number.