From CGS flux to SI flux
Textbooks written before the SI took hold, and many magnet and transformer references that followed them, give magnetic flux in maxwells. Modern calculations and simulation software want webers. This page does the translation in a single step, multiplying the maxwell count by 10 to the minus 8. The result is the same quantity of magnetic flux, now expressed in the coherent SI unit. Because a weber is enormous compared with a maxwell, the output is usually a very small decimal, and the page shows tiny results in exponent notation such as 1e-7. That format is easy to paste into a spreadsheet or a script. The converter has no opinion about whether the flux is realistic, which core it belongs to or what it implies for saturation. It reports the same flux in other units, and the physics stays with the person using the number.
The factor and the default example
The maxwell is defined as one gauss times one square centimeter. Written in SI units, that is 10 to the minus 4 tesla times 10 to the minus 4 square meter, which is 10 to the minus 8 weber. The formula on the page is Wb = Mx × 1e-8. The default input of 10 Mx gives 1e-7 Wb, which is 0.0000001 Wb or 0.1 microweber. The reverse direction multiplies by 100 million, so 1 Wb equals 100,000,000 Mx. A megaline, which is one million maxwells, equals 0.01 Wb, or 10 milliwebers. Those two anchor points help with checking: eight orders of magnitude separate the two units, so any answer that differs from your input by anything other than a shift of eight decimal places deserves a second look. Exponent notation makes that shift obvious at a glance.
Reading exponent notation
A flux of 1e-7 Wb looks unfamiliar to anyone who normally reads decimals. The notation means 1 times 10 to the minus 7, which is a decimal point followed by six zeros and then a one. Similarly, 4.5e-5 means 0.000045. The converter prints results this way when the number is very small, which is typical for maxwell inputs of a few thousand or less. To translate, move the decimal point left by the exponent. Taking 4,500 Mx gives 4,500 × 1e-8, which is 4.5e-5 Wb or 45 microwebers. If you prefer decimals, choose microwebers or milliwebers as the target unit and the result will read more naturally. Spreadsheets, Python, MATLAB and C all understand the e notation, so you can copy the result into code without reformatting, which avoids typing mistakes in long strings of zeros.
A transformer-core style example
Older transformer and relay design notes often give core flux in kilolines or maxwells. Suppose an old handbook says a small core carries a peak flux of 4,500 Mx. Converting gives 4.5e-5 Wb, or 0.045 mWb. With a primary of 800 turns, the flux linkage would be 800 × 4.5e-5, which is 0.036 Wb-turns. For a sinusoidal flux at 60 Hz, the peak induced voltage is 2π f N Φ, which works out to 2π × 60 × 800 × 4.5e-5, or about 13.6 V. That is an illustration of why the conversion is needed: the voltage formula uses webers, and putting maxwells into it by mistake gives a result that is wrong by a factor of 100 million. The numbers here are invented for the example and do not describe any real device, but the method carries over to real handbooks.
Larger fluxes in megalines
Heavy electrical machines, large magnets and some accelerator components work with fluxes in the megaline range. One megaline is 1,000,000 Mx, and the page converts it to 0.01 Wb. A value of 12 megalines, a figure that would have appeared in a generator design note, is 12,000,000 Mx and gives 0.12 Wb. At that scale the SI numbers stop looking tiny and read like ordinary decimals, which is part of why the weber became the standard. If you handle old drawings, a note of 1.5 megalines per pole translates to 0.015 Wb per pole, or 15 milliwebers. Always check whether the figure was per pole, per turn or total, because the maxwell value alone does not say. The converter handles the arithmetic, and your own reading of the source decides how the number is used.
Connecting flux to field and area
For a uniform field perpendicular to a surface, flux equals flux density times area. A flux density of 1 G over 1 cm² is 1 Mx, which is 1e-8 Wb. In SI, 0.1 mT over 1 cm² gives 0.0001 T × 0.0001 m², the same 1e-8 Wb, which shows the factors are consistent. This is useful as a check on a measurement. If a gaussmeter reads 600 G over a pole of 5 cm², the flux is 3,000 Mx, and the page converts that to 3e-5 Wb. The SI route gives 0.06 T × 0.0005 m² = 3e-5 Wb, the same answer. The assumption of uniformity is the weak point: real fields drop off toward edges, so such products are estimates unless the field is mapped or measured with a coil that encloses the whole region.
Why the SI unit won out
The weber is coherent with the volt and the second, since one weber equals one volt-second. That gives Faraday's law a clean form: the induced voltage in volts equals the rate of change of flux in webers per second, multiplied by the number of turns. In CGS, a conversion factor of 10 to the eighth appears whenever flux is tied to volts, because 1 Mx per second induces 10 nanovolts. The 11th General Conference on Weights and Measures adopted the SI in 1960, and the SI Brochure from the BIPM lists the weber as the unit of magnetic flux with the tesla as the unit of flux density. The weber is named for Wilhelm Eduard Weber. The maxwell remains in use mainly in older data and in specific fields such as geomagnetism and astrophysics, where CGS conventions persist.
Common slips in conversion
The most common error is moving the decimal in the wrong direction. Since a maxwell is much smaller than a weber, the number in webers must be much smaller than the number in maxwells. If your result has a bigger magnitude than the input, the units are reversed. A second slip is treating the maxwell as flux density. A printed value in gauss describes flux density, not total flux, and must be converted with a flux density converter. A third slip is forgetting the number of turns when a source quotes flux linkage. Flux linkage has the same unit as flux but means flux multiplied by turns, and the converter cannot tell the difference. Finally, watch for typed exponents. Entering 1e8 where you meant 1e-8 inverts the answer, and a quick look at the order of magnitude catches it.
Limits of the conversion
Here the only thing that changes is the unit system, from CGS to SI. The page does not determine the flux in a magnetic circuit, apply reluctance models, account for fringing or saturation, or confirm a design against ratings, and it cannot tell you whether a flux is safe for implants or stored media. The entered value is taken as a known flux in maxwells. Since the factor is exact, the result carries only the precision of the input. For engineering work that matters, take flux values from manufacturer data, a calibrated fluxmeter or the relevant standard. When documenting results, give both the original maxwell figure and the weber value so that a reviewer can repeat the conversion without guessing which source was the starting point.
Worked examples at three scales
Three quick conversions show the range. A small magnet with 800 Mx of total flux gives 8e-6 Wb, or 8 µWb. A relay core with 60,000 Mx gives 6e-4 Wb, which is 0.6 mWb. A generator pole with 3 megalines, or 3,000,000 Mx, gives 0.03 Wb. In each case the digits of the input stay the same and the exponent shifts by eight places. The examples are illustrative, not data for specific devices. If you place them in one table with the original and converted columns, the table becomes a handy reference for reading older documents and a way to catch typing errors, since the two columns must differ by exactly the same factor on every row. As a further check, 25,000 Mx converts to 0.00025 Wb, which is 250 microwebers, and 1,000 Mx converts to 0.00001 Wb. The 1,000 Mx result, 1e-5 Wb, is the same flux as 10 µWb, which is a quick way to confirm that two converters agree.
Where maxwells still appear today
Although engineering practice moved to the weber, the maxwell has not disappeared. Papers on stellar and solar magnetism commonly quote magnetic flux in maxwells, with sunspot fluxes in the range of 10 to the 21st or 10 to the 22nd maxwells. Converting 1e22 Mx gives 1e14 Wb. Geophysics and some plasma physics texts also keep to CGS conventions. A reader of those papers can use this page to bring values into SI for comparison with laboratory or engineering numbers. Take care with the exponent when entering such large inputs, because a slip from 1e22 to 1e2 changes the result by twenty orders of magnitude, and the converter will dutifully return whichever number you typed. The same caution applies to small values from laboratory work, where a flux of 5e3 Mx is 5e-5 Wb.