SI flux meets CGS flux

Magnetic flux is measured in webers in the SI and in maxwells in the older CGS system, which still shows up on magnet specifications, fluxmeter displays and some textbooks. A nanoweber is a very small amount of flux, the sort a pickup coil sees from a small magnet or a sensor. A technician reading a data sheet in webers and a fluxmeter in maxwells needs a common unit. This page multiplies the nanoweber value by 0.1 and returns maxwells, so 10 nWb is 1 Mx. It suits students, hobbyists who work with magnets and engineers who read both styles of documentation. Older handbooks, vendor catalogs for permanent magnets and some sensor sheets still print maxwells, so the conversion comes up whenever new and old sources are compared.

The relation between Wb and Mx

One maxwell is exactly 10^-8 Wb, which is 10 nWb, so a nanoweber is a tenth of a maxwell. The page applies Mx = nWb × 0.1. The CGS unit is defined as one gauss times one square centimeter, and the SI Brochure from the BIPM and NIST SP 811 give the relation to the weber. The conversion is exact, with no rounding. By hand, divide the nanoweber value by 10. For the reverse, multiply by 10, so 3 Mx is 30 nWb. Because the step is a single power of ten, errors usually come from picking the wrong unit in the menu. If the result is larger than the input, the units are reversed.

Ten nanowebers equal one maxwell

The default of 10 nWb returns 1 Mx. A 500 nWb input gives 50 Mx, and 20,000 nWb gives 2,000 Mx. A 5 nWb input gives 0.5 Mx. In the reverse direction, 100 Mx is 1,000 nWb. Those numbers connect to flux density through the area. If a field of 1 gauss passes through 1 cm², the flux is 1 Mx, or 10 nWb. A refrigerator magnet with a surface field near 50 gauss over 1 cm² therefore carries about 50 Mx, which is 500 nWb. A search coil would see a change of that size when the magnet is pulled away from it, provided the coil covers the same area as the pole face and all of the flux passes through it.

From flux to induced voltage

A coil with N turns links flux N times, and when the flux changes, the coil develops a voltage equal to N times the rate of change of flux. If the flux through a 200-turn coil falls by 500 nWb in 1 ms, the voltage is 200 × 5 × 10^-7 Wb divided by 0.001 s, which is 0.1 V. That is a quick estimate used in simple sensors and in teaching labs. The same change in the CGS unit is 50 Mx. The page gives the unit conversion for the flux, and the voltage calculation is a separate step with its own formula. Check the number of turns on the coil and the time over which the change happens.

Magnet data sheets and gauss-based labels

Magnet suppliers may list the surface field in gauss and the pole area in square centimeters, which gives flux in maxwells directly. A magnet with a flux density of 1,000 gauss across 2 cm² gives 2,000 Mx, which is 20,000 nWb. The same magnet in SI units has a field of 0.1 T and an area of 2 × 10^-4 m², so the flux is 2 × 10^-5 Wb. Both descriptions are the same. When two documents disagree by a factor of 10 or by a factor of 10,000, check whether one uses gauss and the other tesla, and whether the area is in cm² or m². Converting the flux first narrows the cause. A factor of 10,000 usually points to the gauss and tesla mismatch, while a factor of 10,000 in area points to square centimeters against square meters.

Fluxmeters and integrating coils

A fluxmeter integrates the voltage from a coil to display the change in flux. Some instruments show webers or milliwebers, and older ones show maxwells or kilolines. A reading of 150 Mx is 1,500 nWb. When you compare an old reading with a new measurement, convert one of them and use the same coil and turn count. Drift in the integrator is a limit on the accuracy of long measurements, so take the zero before and after, and keep the measurement short. The page converts the reading but does not correct for coil area or drift, and the manual of the instrument is the guide for those. Write both values in the lab notebook, for example 150 Mx (1,500 nWb), so that readers who prefer either unit can follow along.

Reading both units on one chart

A chart that shows flux on a double axis, webers on the left and maxwells on the right, helps readers who know only one unit. Put the factor of 10 between nanowebers and maxwells in the caption, and mark ticks at round values in one of the units. A flux of 50 Mx is 500 nWb, and a flux of 200 Mx is 2,000 nWb. If a plot covers several decades, use a logarithmic axis. The page can generate the paired values for the labels. State the area or the coil used for each measurement, since flux alone does not tell the reader the field strength.

Other units on the list

The menu includes webers, milliwebers, microwebers, nanowebers and picowebers, along with the maxwell. One maxwell is 10 nWb, 0.01 µWb, 0.00001 mWb and 10^-8 Wb. A flux of 0.002 µWb is 2 nWb, which is 0.2 Mx. Going through the base unit is a reliable check: nanowebers times 10^-9 gives webers, and webers divided by 10^-8 gives maxwells, so the net factor is 0.1. For flux density, other pages cover tesla and gauss, since flux and flux density are different quantities. Flux is a total through an area, and density is flux per unit area, which is why the area matters.

Magnet supplier labels in gauss need a field and an area

Flux from a field and an area, the voltage in a coil and the strength of a magnet are separate calculations, and the page cannot judge whether a reading was taken correctly. Real measurements depend on probe position, temperature and stray fields around the sample. For design or safety work, use the data from the magnet supplier, the instrument manual and the standard for your application. Keep the maxwell value in brackets when a supplier sheet is in CGS, so the two documents can be matched. Convert once, from the original value.