Ambient fields through a small coil

The magnetic field of the Earth is a few tens of microtesla at the surface, and the field of nearby mains wiring is far smaller. A pickup coil of a few square centimeters therefore links flux in the range of picowebers to nanowebers. People who build magnetometers, test electromagnetic compatibility or teach induction labs record such values and often switch between the two units as the numbers change. This page multiplies the nanoweber value by 1,000 and returns picowebers. A flux of 5 nWb becomes 5,000 pWb. It helps to confirm numbers copied from a log or a plot. Hobbyists who wind their own search coils and students who repeat an induction experiment can use it to keep a table in one unit as the signal changes with distance from a magnet.

0.1 nWb as 100 pWb by hand

Nano is 10^-9 and pico is 10^-12, so a nanoweber contains 1,000 picowebers. The page applies pWb = nWb × 1,000, using the SI prefixes as fixed in the BIPM SI Brochure and NIST SP 811, so the factor is exact. By hand, move the decimal point three places to the right. A value of 0.1 nWb becomes 100 pWb and 0.047 nWb becomes 47 pWb. To reverse the conversion, divide by 1,000, so 750 pWb is 0.75 nWb. When the output shrinks, the unit menus have been swapped. The step is small, and a quick mental check is usually enough to confirm the page output.

Ten nanowebers and ten thousand picowebers

The default input of 10 nWb returns 10,000 pWb. A 0.1 nWb input gives 100 pWb, and a 2.5 nWb input gives 2,500 pWb. A table that lists flux from several coils may span from a few picowebers to a few hundred nanowebers, and picowebers keep the small entries as whole numbers. When the entries grow, switch to nanowebers so that none of them runs to many digits. The page converts one value at a time, so for a whole table, use a spreadsheet with the same factor and use the page to verify a few rows by hand. A spot check of the smallest and the largest entry is the quickest way to find a column that was scaled twice.

The flux of the Earth field through a coil

The Earth field at the surface is roughly 25 to 65 microtesla, depending on location. Take 50 µT, which is 5 × 10^-5 T, and a coil face of 1 cm², which is 10^-4 m². The flux is 5 × 10^-9 Wb, or 5 nWb, which is 5,000 pWb. A phone magnetometer measures the field and not flux, but the example shows the scale of flux through a small area. If the coil is tilted, the flux falls with the cosine of the angle between the field and the coil normal. A coil with many turns links the flux once for each turn, and flux linkage multiplies the value by the number of turns. For a 200-turn coil, the 5 nWb of this example becomes 1,000 nWb of flux linkage, which is the quantity that sets the voltage when the field changes.

Mains hum picked up by a coil

The magnetic field near wiring and appliances varies with the load. Take a field of 0.1 µT peak at 60 Hz through a coil of 10 cm², which is 10^-3 m². The flux is 10^-10 Wb, or 100 pWb. A coil of 1,000 turns develops a peak voltage of about the turns times 2π times the frequency times the peak flux, which is 1,000 × 377 × 10^-10, about 38 µV. That is the order of magnitude of hum that sensitive measurements must reject, and it is why shielding and twisted wiring matter. These numbers are illustrative and depend on the real field, which you can measure with a calibrated probe.

From picowebers back to nanowebers

To convert the other way, choose picowebers as the From unit and nanowebers as the To unit. A reading of 4,200 pWb is 4.2 nWb, and 90 pWb is 0.09 nWb. This is useful when you read a very sensitive instrument in picowebers and need to compare the result with a threshold from a data sheet quoted in nanowebers. Because the factor is 1,000, an error shows up as a result off by that amount. Keep the unit with every number in your notes, and avoid editing the digits by hand, since a dropped zero is the most common error at this level. Where a reading changes with time, record the time stamp beside it.

Noise and drift in small-flux measurements

An integrating fluxmeter drifts, since any offset in the amplifier accumulates over time. For a flux of a few hundred picowebers, a drift of 50 pWb over a minute can be a large fraction of the signal. Short measurements, good zeroing and a stable temperature help, and many instruments have a reset button for the integrator. Averaging several runs and reversing the direction of the field or the coil reduce errors from offsets. When you write the result, report the drift next to the value. The converter handles the unit, and the instrument manual tells you how large the drift can be.

Neighbors on the menu

The unit list includes webers, milliwebers, microwebers, nanowebers, picowebers and maxwells. One nanoweber is 0.001 µWb, 10^-6 mWb and 0.1 Mx. A flux of 3,000 pWb is 3 nWb, which is 0.3 Mx. A good way to avoid a slip is to move one step at a time: from pico to nano is a division by 1,000, and from nano to micro is another. Webers are SI units, and maxwells are CGS units used on older equipment. When a data sheet or a book uses maxwells, convert to webers first and then to the unit you prefer, since each conversion on this list is a clean power of ten.

Coil geometry and mains hum in picoweber work

Computing flux from a field, estimating coil voltage and assessing shielding sit outside a unit rescale. Measurements at the picoweber level depend on the coil geometry, the instrument bandwidth and the environment, so two setups can give different readings for the same source. Follow the instrument manual and the standard for your measurement, and document the conditions along with the numbers. Note the coil area, the number of turns, the distance to nearby metal and the time of day, since mains fields vary through the day. Repeat the reading at a different hour to see the hum.