Reading a flux from core to sensor

A magnetic core or a magnet carries a flux that is conveniently written in milliwebers. A sensitive magnetometer or a research coil detects changes that are many orders of magnitude smaller, and their specifications use picowebers. Someone who builds a measurement from a magnet to a sensor, or who reads a paper that uses picowebers, needs both on the same scale. This page multiplies by one billion. Ten milliwebers become 10,000,000,000 picowebers. The size of the number shows how much gap exists between a bench magnet and the threshold of a sensitive instrument. Keep the unit written beside each value, since a pWb figure and a mWb figure look the same without it. In a shared spreadsheet, a unit column next to the value column prevents a reviewer from guessing.

A billion picowebers in a milliweber

Milli is 10^-3 and pico is 10^-12, so the ratio is 10^9. The formula is pWb = mWb × 1,000,000,000. The prefixes are defined in the BIPM SI Brochure and NIST SP 811. The decimal point moves nine places to the right. A way to check by hand is to go through the intermediate steps: one milliweber is 1,000 microwebers, 1,000,000 nanowebers and 1,000,000,000 picowebers. A flux of 0.003 mWb is 3,000,000 pWb, and 2 mWb is 2,000,000,000 pWb. Because the numbers grow quickly, many people enter the value first and then read the result with the thousands separators in mind, so that 2,000,000,000 is read as two billion. The page reproduces those results for any input, and reading digits in groups of three is a good habit with numbers this long.

Copying 1 × 10^10 pWb into a report

The page opens with 10 mWb and shows 10,000,000,000 pWb, which is 1 × 10^10. Scientific notation is easier to copy. A smaller flux of 0.003 mWb is 3,000,000 pWb, and a flux of 2 mWb is 2,000,000,000 pWb. In the opposite direction, 500,000,000 pWb is 0.5 mWb, and 7,500 pWb is 0.0000075 mWb. These examples show that the picoweber is useful only for very small fluxes. Writing the flux of a core in picowebers would produce huge numbers that are hard to read. Pick the unit that keeps a number between 1 and 1,000, and convert only when two sources use different prefixes.

Magnetometers and the flux quantum

Superconducting quantum interference devices, known as SQUIDs, are among the most sensitive flux detectors. The flux quantum, h divided by twice the electron charge, is about 2.07 × 10^-15 Wb. That is 2.07 femtowebers, and in picowebers it is 0.00207 pWb. The comparison shows why picowebers are a convenient unit for instruments that sit well above a single quantum but far below a core flux. A 10 mWb magnet flux is about 5 × 10^12 flux quanta, a number that illustrates the range. The page does not model sensors, and it only expresses the units consistently when you read papers and data sheets.

Search coils and pulse integration

A search coil gives an output voltage proportional to the rate of flux change, and integrating that voltage over a pulse gives the flux change itself. A single-turn coil with an integrated signal of 5 × 10^-9 V·s has seen 5,000 pWb. With 200 turns, the integral of the induced voltage would be 200 times that for the same flux, so a record of the turns is important. The result depends on the integrator gain and the drift in the electronics, so check with a known reference. Converting a reading between milliwebers and picowebers helps when a calibration certificate and a measurement are in different prefixes.

From picowebers back to milliwebers

To go from picowebers to milliwebers, set the source to pWb. The page divides by one billion. A reading of 750,000 pWb is 0.00075 mWb, and 2,500,000,000 pWb is 2.5 mWb. For values given in scientific notation, subtract nine from the exponent: 4 × 10^6 pWb becomes 4 × 10^-3 mWb. Many errors come from an exponent that is off by three, which is the difference between pico and nano, or between nano and micro. Check that the page output matches the order of magnitude you expect, and flag any result that differs by a factor of 1,000. When two colleagues report the same flux with different prefixes, converting both to the same unit settles the question in seconds.

Choosing prefixes for readability

A report that lists flux values should use one prefix per table whenever possible. If the values range from 10 mWb down to 5,000 pWb, a table in milliwebers shows 10 and 0.000005, and a table in picowebers shows 10,000,000,000 and 5,000. Neither is pleasant. Splitting the table into two groups, each with its own unit, reads better. Scientific notation is a third option. The point of the converter is to make the choice quick, since you can try a unit and see whether the numbers fall in a convenient range. State the unit in the column header so the table is clear at a glance.

Weber, volt-second and Faraday's law

The weber equals one volt-second, which is why flux readings from integrators are in webers. A coil of N turns that links a flux Φ has a flux linkage of N times Φ, and the induced voltage is the rate of change of that linkage. For a change of 3,000,000 pWb, which is 0.003 mWb, over 1 ms in a 10-turn coil, the average voltage is 10 × 3 × 10^-6 Wb ÷ 0.001 s = 0.03 V. These relations tie the units together. The page converts only the flux value, and the example is a reminder of how a unit change fits into a measurement.

Sensor sensitivity and shielding are separate questions

The conversion restates a flux in a different unit. It does not tell you how sensitive a sensor is, what shielding a measurement needs, or whether a flux level is safe or suitable for a process. Magnetic measurements are sensitive to external fields, temperature and the placement of the coil, and the documentation of the instrument explains how to control them. Use the standard or the data sheet that applies to your work, and keep the full precision of the source reading until the last step, then use the page for consistent prefixes in notes and calculations. Record the unit and the instrument range beside every value you copy, since a flux without its unit cannot be checked later.