Core and pole flux in the milliweber range
The flux in a small transformer core, a relay or a motor pole is usually a fraction of a milliweber. A sensing coil or a hall-effect probe near the same part may report flux changes in picowebers. A student who relates the two, or a technician who builds a table from a core datasheet and a probe log, needs one unit. This page divides a picoweber figure by 10^9 and returns milliwebers. It also converts back, so a core flux in milliwebers can be written in picowebers when a table works with the smaller unit. The conversion is short, and it keeps a ratio of a billion visible instead of buried in a string of zeros.
Nine places and a billion
Milli is 10^-3 and pico is 10^-12, so one milliweber equals 10^9 picowebers. The formula is mWb = pWb × 1e-9. The SI Brochure defines the weber as one volt-second and fixes the prefixes, so the factor is a defined ratio. By hand, move the decimal point nine places left. A flux of 480,000,000 pWb is 0.48 mWb, and 2,500,000,000 pWb is 2.5 mWb. If your answer is larger than the input, the units were reversed, since the milliweber is the larger one. A two-step check passes through the weber: divide by 10^12 for webers, then multiply by 1,000 for milliwebers, and the product of the two steps is the factor of 10^-9.
Reading 1e-8 mWb for the default
The default of 10 pWb gives 1 × 10^-8 mWb, which is 0.00000001 mWb. The page may show a binary rounding tail such as 9.999999999999999e-9, and the value to report is 1e-8. The figure shows how small a picoweber is next to the flux values that appear on a magnetic component. A probe that registers 10 pWb is working with a very weak field or a very small area, and the ratio to a core flux of half a milliweber is about fifty million to one. Reporting the exponent form and keeping the original 10 pWb in the text makes the conversion easy to audit.
Flux in a small transformer core
Flux through a core is the flux density times the cross-sectional area. Take a silicon steel core with an area of 6 cm², which is 6 × 10^-4 m², working at 0.8 T (an illustrative operating point). The flux is 0.8 × 6 × 10^-4 = 4.8 × 10^-4 Wb, which is 0.48 mWb, or 480,000,000 pWb. Core data sheets and design notes give flux density, and the area comes from the lamination stack, so this multiplication is a routine step before a conversion. The page performs only the unit change after the flux is known. It does not compute flux from density, and the area must be in square meters when the density is in tesla.
What that flux means for the winding
For a sinusoidal supply, the RMS voltage across a winding is about 4.44 × frequency × turns × peak flux. At 50 Hz, with 500 turns and a peak flux of 0.48 mWb, the voltage is 4.44 × 50 × 500 × 0.00048 = 53.28 V. Designers use this relation to choose the number of turns for a given core and supply. The same flux in picowebers is 4.8 × 10^8 pWb, a figure that fits a sensor log, but the formula wants webers, so a conversion to milliwebers and then to webers avoids a slip of three powers of ten. This page supplies the unit step. The formula and the choice of the peak value belong to the design.
Milliwebers and maxwells
Older magnet and instrument literature uses the maxwell, the CGS unit of flux, where one maxwell is 10^-8 Wb. One milliweber is therefore 100,000 maxwells, and 0.48 mWb is 48,000 maxwells. The unit lists on this page include maxwells, so a figure from an older source can be converted directly. The gauss is a maxwell per square centimeter, and it is a flux density, not a flux. A table that lists 4,800 gauss for a core and 6 cm² implies a flux of 28,800 maxwells, which is 0.288 mWb. Check which of the two quantities a document gives, because the unit names are close and the physical meaning is different.
Back from milliwebers to picowebers
Choose milliwebers as the source and picowebers as the target to go the other way. Every milliweber is 10^9 pWb, so 0.2 mWb is 2 × 10^8 pWb and 2.5 mWb is 2.5 × 10^9 pWb. Large values like these appear when a program stores all flux as an integer count of the smallest unit. A 32-bit integer tops out near 2.1 × 10^9, which is only about 2.1 mWb in picowebers, so a core flux larger than that would overflow such a field. Use a wider integer type or a floating-point value in webers for storage, and convert to milliwebers or picowebers for display. The page itself has no such limit, because it works with floating-point numbers.
mWb, MWb and the missing prefix
A lowercase m is milli and a capital M is mega, so mWb and MWb differ by a factor of 10^9. A flux of 0.48 MWb would be an absurd value for a core, which is how such a slip is often noticed. In plain text files the micro sign is often written as u, and µWb can be mistaken for mWb. Each swap shifts the answer by three or nine powers of ten. Write the unit in full in the column header, for example flux in milliwebers, and compare the converted value with the order of magnitude you expect for the component. A flux of a few milliwebers is large for a small core and small for a power transformer.
Saturation and design margins stay with the datasheet
Core steel saturates at a flux density of roughly 1.5 to 2 T, depending on the material, and the flux that a core can carry follows from its area. The page does not model saturation, hysteresis, losses or temperature. It converts a number from one unit to another. For a real design, use the manufacturer datasheet, the applicable standard and the software that suits the part, and for mains-connected equipment follow the safety rules where you work. The factor of 10^-9 is a defined ratio, so a surprising result usually comes from a swapped pair of units, a lost digit or a figure that was a flux density and not a flux.