Four calculators around one relationship
The electrical hub holds the Voltage Calculator, Current Calculator, Resistance Calculator and Electrical Power Calculator. They revolve around Ohm's law, published by Georg Ohm in 1827, which says that voltage equals current times resistance: V = I × R. Given any two of the three quantities, you can find the third. Power links in through P = V × I, and by substitution P = I² × R and P = V² / R. Pick the calculator for the quantity you are missing. The inputs are the two you know, and the rest follows from the same two or three equations. For instance, the Voltage Calculator answers what voltage appears across a part given its current and resistance, the Current Calculator answers how much flows given voltage and resistance, and the Resistance Calculator answers what value gives a target current at a known voltage. The Electrical Power Calculator completes the set by telling you how much heat or work the circuit produces.
Voltage, current and resistance, in plain terms
Voltage is the electrical pressure that pushes charge around a circuit, measured in volts. Current is the rate of charge flow, measured in amperes, where one ampere is one coulomb per second. Resistance is the opposition to flow, measured in ohms. A 12 V battery across a 4 Ω resistor drives 3 A. The same battery across 12 Ω drives 1 A. Doubling the resistance halves the current at a fixed voltage, which is a useful picture to hold when a result looks surprising. A very low resistance, such as a short circuit, gives a very large current, which is why fuses and breakers exist.
Power and why it grows with the square
Power is the rate at which a circuit converts electrical energy, in watts. At 12 V and 3 A the power is 36 W. Because P = I² × R, doubling the current through a fixed resistance quadruples the heat produced. The same square law applies to voltage, since P = V² / R. This explains why overloaded wires warm up quickly and why a resistor that is comfortable at 20 mA may burn at 60 mA. When choosing a resistor, pick a power rating well above the calculated dissipation, and a factor of two margin is a common practice. A 100 Ω resistor carrying 0.2 A dissipates 100 × 0.04 = 4 W, far beyond a quarter-watt part. Heating cables, toasters and space heaters are built around this dissipation, while wiring is designed to waste as little as possible, which is why thicker conductors with lower resistance carry large currents.
An appliance example: a kettle on mains
A kettle rated 2,300 W on a 230 V supply draws 2,300 / 230 = 10 A. Its heating element has a resistance of 230 / 10 = 23 Ω while hot. On a 120 V supply the same element would draw only 5.2 A and deliver about 626 W, which is why appliances are built for a particular voltage. If the kettle runs for half an hour it uses 1.15 kilowatt-hours of energy, the unit on household electricity bills. Energy is power multiplied by time, which these power calculations feed into, though kilowatt-hours are a separate step.
A circuit example: sizing a resistor for an LED
To drive an LED from a 5 V supply, you subtract the LED's forward voltage, say 2 V for a red LED, leaving 3 V across the series resistor. For a 20 mA target current, the resistance is 3 / 0.02 = 150 Ω. The resistor dissipates 3 × 0.02 = 0.06 W, well within a quarter-watt part. The Resistance Calculator and Electrical Power Calculator answer both halves of this design. The forward voltage and current values come from the LED datasheet, and real LEDs vary, so treat the result as a starting point and round to the nearest standard resistor value. Resistors come in preferred series, and in the common E12 series the nearest values to 150 Ω are 150 itself and 180. Rounding up to a larger value lowers the current slightly, which is the safer direction for the LED. At 5 V, a 180 Ω resistor gives 3 / 180 = 16.7 mA, a little dimmer and perfectly adequate. A blue or white LED with a forward voltage near 3 V changes the answer sharply, leaving only 2 V for the resistor.
Direct current, alternating current and power factor
The four calculators here are written for direct current, with inputs labeled DC voltage and DC current, and they do not model power factor. Ohm's law also holds for purely resistive loads on alternating current, using RMS values. Motors, transformers and many electronic supplies are not purely resistive, so the current and voltage are out of step. Real power then equals V × I × power factor, and the product V × I alone is apparent power in volt-amperes. A motor load drawing 5 A at 230 V with a power factor of 0.8 uses 920 W of real power, not 1,150 W. Keep this in mind when comparing a nameplate current with a power figure.
Units and prefixes
Electrical values usually come with prefixes. Milliamperes are thousandths of an ampere, kilohms are thousands of ohms, and kilovolts are thousands of volts. A sensor drawing 4 mA is 0.004 A, and a 2.2 kΩ resistor is 2,200 Ω. Mixing prefixes is the main source of wrong answers: entering 20 for milliamperes where amperes are expected gives a result 1,000 times too large. Convert to base units first, volts, amperes, ohms and watts, then calculate. Convert the answer to a friendlier prefix afterward if you wish.
Electrical errors with voltage and resistance
Several errors recur. Using a nominal battery voltage that sags under load gives optimistic current estimates. Ignoring the resistance of wires and connections, which matters at high currents or over long runs, leads to lower voltage at the load than expected. Treating a component's resistance as constant is wrong for lamp filaments and many semiconductors, whose resistance changes with temperature. A light bulb's cold resistance can be a tenth of its hot value, which causes a brief surge at switch-on. Check that your numbers describe the same operating condition. Series and parallel combinations need extra steps outside these four relationships: resistances in series add, while parallel resistances combine through their reciprocals, so two 100 Ω resistors in parallel behave as 50 Ω. A reading taken with a multimeter has its own uncertainty, and a cheap meter can be off by a percent or more, which carries into every computed value.
Safety and the limits of a calculator
These calculators do plain circuit arithmetic. They do not check wire gauge, breaker ratings, insulation, grounding or local electrical code, and they should not be used as the basis for installation work on mains wiring. Voltages above about 50 V AC can be dangerous, and mistakes with mains power can cause fires, shock or death. For household or industrial circuits, a licensed electrician and the applicable wiring regulations decide what is safe. Use the calculators for learning, for low-voltage electronics and for sanity checks of numbers you already trust.
Frequently asked questions
- What is Ohm's law?
- Voltage equals current times resistance (V = I × R). Knowing two of the three values gives the third.
- How do I find power from voltage and current?
- Multiply them: P = V × I. Using Ohm's law you can also write P = I² × R or P = V² / R.
- Why do I get a wrong answer when I enter milliamperes?
- The formulas expect base units. Convert milliamperes to amperes by dividing by 1,000, or the result will be off by a factor of 1,000.
- Do these calculators handle AC?
- They take DC voltage and current. Ohm's law also holds for resistive AC loads using RMS values, but motors and other reactive loads need power factor and impedance, which these pages do not model.