How much heat one kilogram needs per degree
Specific heat capacity is the heat required to raise the temperature of one unit of mass by one degree. The SI unit is the joule per kilogram kelvin, J/(kg·K). It links mass, temperature change and heat through Q = m × c × ΔT, and it appears in kettle calculations, heat exchanger design, cooking, climate science and building thermal mass. This hub lists 15 converters, led by the Specific heat capacity converter, covering J/(kg·K), kJ/(kg·K), J/(g·K), thermochemical calories per gram Celsius degree, and International Table BTU per pound Fahrenheit degree. Each tool takes a value, a source unit and a target unit.
Exact factors behind the unit pairs
The thermochemical calorie is 4.184 J, so 1 cal/(g·°C) equals 4,184 J/(kg·K), or 4.184 kJ/(kg·K). The International Table BTU is 1,055.05585 J, the pound is 0.45359237 kg, and a Fahrenheit degree is 5/9 kelvin, so 1 BTU/(lb·°F) equals 4,186.8 J/(kg·K). The two imperial and metric traditions therefore give almost the same number for the same substance, within about 0.07 percent. The Joules per kilogram kelvin to Joules per gram kelvin converter divides by 1,000, and the Thermochemical calories per gram Celsius degree to International-table BTU per pound Fahrenheit degree converter returns about 0.9993. The tools keep the calorie and BTU definitions explicit, so check which one a source used.
Reference values
Liquid water is the benchmark at about 4.18 kJ/(kg·K), or exactly 1 cal/(g·°C) by the old definition of the calorie. Ice is about 2.1 kJ/(kg·K), steam about 2.0, ethanol about 2.4, and air at constant pressure about 1.005. Metals are far lower: aluminum is about 0.90 kJ/(kg·K), iron about 0.45 and copper about 0.385. The Kilojoules per kilogram kelvin to Joules per kilogram kelvin converter writes copper as 385 J/(kg·K). That is why a copper pan heats quickly and water takes so much energy to warm. Values shift with temperature and purity, and gases have different values at constant pressure and constant volume.
Heating water, worked through
To warm 2 kg of water from 20 to 80 degrees Celsius, use Q = 2 × 4.184 × 60 = 502.08 kJ. A 2 kW kettle element supplies 2 kJ each second, so the time is about 251 seconds if all the heat goes into the water, and a little longer in practice. The same job in imperial units uses water at 1 BTU/(lb·°F): 4.409 lb heated by 108 Fahrenheit degrees needs about 476 BTU, because 4.409 × 108 = 476.2. The Kilojoules per kilogram kelvin to International-table BTU per pound Fahrenheit degree converter turns 4.184 kJ/(kg·K) into about 0.9993 BTU/(lb·°F). Both routes agree once the units match, which is the point of converting before computing. A second case uses a different substance: heating 5 kg of aluminum from 20 to 220 degrees Celsius takes 5 × 0.897 × 200 = 897 kJ, which is less than a quarter of the 4,184 kJ needed to heat the same mass of water by the same amount. The Joules per kilogram kelvin to Kilojoules per kilogram kelvin converter shows the aluminum value of 897 J/(kg·K) as 0.897 kJ/(kg·K), so the table and the formula can share one unit.
Intervals, not temperatures
The denominator of a specific heat unit is a temperature difference. A change of 1 degree Celsius equals a change of 1 kelvin, and a change of 1 Fahrenheit degree equals 5/9 kelvin. No offset such as 273.15 or 32 enters the conversion, which differs from converting a temperature reading on the temperature topic. This is why cal/(g·°C) and cal/(g·K) are the same unit in size. Mixing the two ideas is a common source of error: applying the Fahrenheit offset to a heat capacity value produces nonsense. The converters in this hub use the scale factor only, so you can enter specific heats from any of the listed unit systems without a correction.
Specific heat, heat capacity and thermal mass
Specific heat capacity is per kilogram, while heat capacity is per object, in J/K. A 3 kg copper block has a heat capacity of 3 × 385 = 1,155 J/K. Building designers talk about thermal mass: a concrete slab of 2,400 kg/m³ with a specific heat near 0.88 kJ/(kg·K) stores about 2.1 MJ per cubic meter for each kelvin, which explains why heavy buildings change temperature slowly. Multiply the specific heat by mass to reach heat capacity, using the same unit system. The heat capacity topic on this site converts whole-object values, and entering a per-kilogram figure there would be off by the mass of the object.
Cooking, climate and process work
The high specific heat of water moderates coastal climate and makes hot water a good heat carrier in radiators. A kilogram of water cooling by 10 K releases 41.8 kJ, enough to warm 10 kg of aluminum by roughly 4.6 K. In the kitchen, sugary and fatty foods have lower specific heat than water, so a pie filling can burn the mouth while the crust feels cool. Industrial heat-transfer fluids are chosen partly on this value, with glycol-water mixtures around 3.3 to 3.8 kJ/(kg·K) depending on concentration. When a data sheet lists a value in J/(g·K) the Joules per gram kelvin to Joules per kilogram kelvin converter makes it match SI tables.
Limits and cautions
Specific heat varies with temperature, and a single number is an average for a range. For phase changes, latent heat adds to the sensible heat computed here: melting ice absorbs about 334 kJ/kg at constant temperature. Specific heat at constant pressure and at constant volume differ for gases, and the tools do not choose between them. They also do not convert between heat capacity, specific heat and molar heat capacity. Carry the basis through your calculation: per kilogram, per gram, per pound, per mole. The listed units are all per unit of mass, so a value per mole must be converted to mass first using the molar mass. Water at 75.3 J/(mol·K) and a molar mass of 18.015 g/mol gives 4.18 J/(g·K), for instance. Moisture also changes the specific heat of soils, grains and foods, since the water fraction contributes a large share: a damp material can have a specific heat well above that of the dry solid, so use a value that matches the actual moisture content.
Frequently asked questions
- What is the specific heat of water in J/(kg·K)?
- About 4,184 J/(kg·K) using the thermochemical calorie, and about 4,182 at 20 degrees Celsius from measurements.
- Is cal/(g·°C) the same as BTU/(lb·°F)?
- Almost. 1 cal/(g·°C) is 4,184 J/(kg·K) and 1 BTU/(lb·°F) is 4,186.8 J/(kg·K), a difference of about 0.07 percent.
- Do I apply the 32 degree offset to specific heat?
- No. The denominator is a temperature interval, so only the 5/9 scale factor applies.
- What is the difference from heat capacity?
- Heat capacity is for a whole object in J/K, while specific heat is per kilogram. Multiply by mass to move from one to the other.