Two traditions that nearly agree
Chemistry and physics handbooks quote specific heat in calories per gram per degree Celsius, while US heating, process and mechanical engineering use BTU per pound per degree Fahrenheit. The two were built so that water has a specific heat of about 1 in both. That near-equality is convenient and also a trap, because it hides a small difference that matters when you convert a precise value. This page applies the exact ratio between the thermochemical calorie version and the International Table BTU version. A reader with a table in cal/(g·°C) and a design spreadsheet in BTU/(lb·°F) gets a figure that respects both definitions. Process plant data sheets, boiler calculations and HVAC load software often use BTU per pound per degree Fahrenheit, while the underlying property data comes from chemistry literature.
Where 0.999331231489 comes from
One cal th/(g·°C) is 4,184 J/(kg·K). The International Table BTU is 1,055.05585262 J, a pound is 0.45359237 kg exactly, and a Fahrenheit degree interval is 5/9 of a kelvin. One BTU IT/(lb·°F) is therefore 1,055.05585262 divided by 0.45359237 times 5/9, which equals 4,186.8 J/(kg·K), the same value as the International Table calorie per gram per degree. The ratio 4,184 divided by 4,186.8 is 0.999331231489. Because the International Table BTU is defined from the International Table calorie, 4,186.8 is also the value you would get from 4.1868 J per gram per kelvin multiplied by 1,000. NIST SP 811 gives the thermochemical calorie, and the International Table values come from the 1956 steam table conference definitions.
Reading the default of ten
An input of 10 cal th/(g·°C) gives 9.99331231489 BTU IT/(lb·°F). The value 10 is an artificial round number, since no common material has a specific heat that large. Hydrogen gas at constant pressure is about 3.4 cal/(g·°C) and liquid water is near 1. Still, the output shows the size of the correction clearly: it is about 0.067 percent below the input. That difference is far smaller than the spread between handbook sources, which means that a rough estimate can treat the two units as equal. Cooling a 5 lb batch of water by 40 Fahrenheit degrees removes 200 BTU by either figure, with the exact factor changing it by about 0.13 BTU. For a calibration certificate or a code comparison, the exact factor is the safer choice. Software that treats the calorie and the BTU as equal per pound and gram would reproduce the table of the original source to only three digits.
Metals, water and ice in both units
Aluminum at 0.215 cal th/(g·°C) converts to 0.21486 BTU IT/(lb·°F). Iron at 0.107 gives 0.10693, and ice at 0.5 gives 0.49967. Water at 1.0 gives 0.99933, so a pound of water needs about 0.9993 BTU to warm by one Fahrenheit degree under the thermochemical figures, although many US sources simply state 1. Ethanol at 0.58 gives 0.57961. These values show that the conversion changes the fourth significant digit, which matters for precise energy balances and not for a quick estimate of a water heater load. Raising 50 gallons of water by 70 Fahrenheit degrees takes about 29,200 BTU if a gallon weighs 8.34 lb and the specific heat is 1, and the exact factor changes that figure by only about 20 BTU.
Using the result in a heating calculation
The heat needed for a temperature change is mass times specific heat times the rise. In US units, a 200 lb aluminum part heated by 300 Fahrenheit degrees with a specific heat of 0.21486 BTU/(lb·°F) needs 200 times 0.21486 times 300, or 12,891.6 BTU. Using 0.215 instead would give 12,900 BTU, a difference of 0.07 percent. In a furnace or kiln estimate, losses and uncertainty in the part mass dwarf that difference, so the exact factor is mainly a matter of consistency and traceability between sources. The same part in SI units, using the J/(kg·K) converter, shows the identical 899.56 J/(kg·K) figure when the starting value is 0.215.
Going from BTU units back to calories
Select BTU IT per pound Fahrenheit degree in the From menu and the calorie unit in the To menu. The page divides by 0.999331231489, which multiplies by 1.000669216. A specific heat of 0.24 BTU IT/(lb·°F), a common figure for dry air in US sources, becomes 0.24016 cal th/(g·°C), and 1 BTU IT/(lb·°F) becomes 1.00067. Dry air in SI is about 1,005 J/(kg·K), which is 0.2402 cal th/(g·°C), so the figures agree. The agreement within 0.1 percent is typical, and it is why engineers can move between a chemistry table and an air-conditioning calculation without adjusting values.
IT versus thermochemical
Both calories and both BTUs have more than one definition. The thermochemical BTU is about 1,054.35 J, a different value from the International Table BTU of 1,055.06 J, and the International Table calorie is 4.1868 J instead of 4.184 J. This page keeps the calorie as thermochemical and the BTU as International Table, as its labels say. A source that does not name the variant leaves a possible difference of up to 0.07 percent. If you need to combine data sets precisely, identify which variants each one uses. Steam tables use the International Table units, while combustion and thermochemistry data from NIST and the JANAF tables use thermochemical joule-based values.
The temperature denominators
The denominators in both units are temperature differences. A Celsius degree interval is 1.8 Fahrenheit degrees, and the factor already accounts for that, as part of the equality of 4,186.8 J/(kg·K) and BTU/(lb·°F). Never add 32 or 273.15 here, since those offsets apply to absolute scale readings, not to the size of a degree. A change of 10 Celsius degrees equals 18 Fahrenheit degrees, and the factor accounts for that change of scale built into the unit.
How precise to be
The factor is exact to the digits shown, so conversions carry the precision of the input. A table that lists 0.215 for aluminum and 0.107 for iron has only three significant digits, so the result for iron reads as 0.107 BTU/(lb·°F) to that precision and the extra digits are only arithmetic. Handbook specific heats are usually given to three digits, so keep three or four digits in the result. Rounding too early compounds when several converted values are multiplied together in a load calculation, so carry the full number until the final line.