Measurement basis
A Celsius reading maps to the kelvin reference with the 273.15 zero-point offset.
Definition conventions
Temperature scales use both scaling and offsets. Absolute temperature cannot be below zero kelvin.
Conversion method
For a reading, add 273.15 to °C to obtain K. A Celsius temperature difference uses the scale factor without that offset.
Reference equivalent of °C
a temperature reading of 1 °C = approximately 274.15 K.
Worked example
Known input: 10 °C. Reference equivalent: 283.15 K. The return conversion gives approximately 10 °C.
The worked °C value is a reading, so the reference result includes the zero-point offset.
Common reference values
| Input (°C) | Reference equivalent (K) |
|---|---|
| 1 | 274.15 |
| 5 | 278.15 |
| 10 | 283.15 |
| 25 | 298.15 |
| 50 | 323.15 |
| 100 | 373.15 |
Compare one °C with other units
| Target unit | Equivalent of 1 °C | Definition guide |
|---|---|---|
| Kelvin (K) | 274.15 | Read definition |
| Fahrenheit (°F) | 33.8 | Read definition |
| Rankine (°R) | 493.47 | Read definition |
A scale that is the kelvin shifted by 273.15
The degree Celsius is the SI-accepted unit of Celsius temperature, defined through the kelvin by t/°C = T/K − 273.15. A change of one degree Celsius is therefore exactly the same size as a change of one kelvin, and the two scales differ only in where zero sits. The SI Brochure names degree Celsius as a special name for the kelvin used to express Celsius temperature. Water at ordinary pressure freezes close to 0 °C and boils close to 100 °C, but those are properties of water and not the definition. The triple point of water, 273.16 K, is 0.01 °C. Since the 2019 SI revision the kelvin is fixed by the Boltzmann constant, 1.380649 × 10⁻²³ J/K, and the Celsius scale follows from it.
Anders Celsius and the name change
The scale is named for the Swedish astronomer Anders Celsius, who described a centigrade thermometer in 1742. His original scale was upside down by modern habit, with 0 at the boiling point of water and 100 at the freezing point, and it was reversed soon after his death, with credit shared among later Swedish scientists. Through the nineteenth and early twentieth centuries the scale was called centigrade, meaning one hundred steps. In 1948 the 9th General Conference on Weights and Measures adopted the name degree Celsius, partly to avoid confusion with the angle unit grade. The name change is well documented. The exact sequence of who reversed the scale is less settled, so the history here sticks to the documented points.
The conversion formulas
Celsius connects to the other scales with a scale factor and an offset. Kelvin is t + 273.15, so 25 °C is 298.15 K. Fahrenheit is t × 9/5 + 32, so 25 °C is 77 °F, 37 °C is 98.6 °F and 100 °C is 212 °F. The two scales cross at −40, where −40 °C equals −40 °F. Rankine is (t + 273.15) × 9/5, which gives 536.67 °R at 25 °C. The temperature converter on this site goes through kelvin for every pair, applying both the offset and the scale factor. A reading of 20 °C is 68 °F, and 0 °C is 32 °F. The multiplication by 9/5 applies after the offset adjustments, so the order of operations matters when you do it by hand.
Everyday and scientific anchor temperatures
Anchors help check an answer. Absolute zero is −273.15 °C. Water freezes near 0 °C and boils near 100 °C at standard atmospheric pressure, 101.325 kPa, and the boiling point falls roughly 1 °C for every 300 meters of altitude, so water boils near 95 °C at about 1,500 meters. Normal human body temperature is commonly quoted as about 37 °C, though individual and daily variation spans a degree or more. Room temperature is often taken as 20 to 22 °C. A kitchen oven set to 180 °C is 356 °F. Liquid nitrogen boils at about −196 °C, and the surface of the Sun is near 5,500 °C. The same number can therefore mean comfort, danger or physics depending on the field.
Temperature readings versus temperature changes
A temperature reading and a temperature change use the same symbol but behave differently under conversion. A reading from 20 °C to 30 °C is a rise of 10 °C, which equals 10 K and 18 °F. The offset cancels in a difference, so only the scale factor applies: multiply by 1.8 for Fahrenheit. Writing the change as 10 K, or as 10 °C with the word difference or the symbol Δ, keeps the meaning clear. NIST SP 811 notes that the unit is the same for both uses. In engineering formulas for heat, expansion and conductivity, the temperature appears as a difference, so use the change figure and never run a Celsius reading through the 32-degree offset in those equations.
Notation rules for writing degrees
The correct style puts a space between the number and the symbol: 25 °C, not 25°C or 25C. The degree sign belongs with the C, so °C is a unit symbol, and the word is degree Celsius with a capital C because it is named after a person. The unit is written lowercase when spelled out generally, as in degrees Celsius, with the capital C retained. The kelvin takes no degree sign, so write 298.15 K and not 298.15 °K. Negative values take a true minus sign, as in −18 °C. Ranges look like 20 °C to 25 °C, or 20 to 25 °C if the unit is shared. In plain text without the degree sign, deg C is acceptable but should be used consistently.
Where the Celsius scale is the default
Most of the world uses Celsius for weather, cooking, medicine and school science, and the scientific literature uses it for temperatures near ambient. The United States relies on Fahrenheit for weather and cooking while using Celsius in laboratories. A forecast of 30 °C is 86 °F, a freezer at −18 °C is about 0 °F, and a 4 °C refrigerator setting is 39.2 °F. Food safety guidance includes temperatures such as 74 °C for cooked poultry in US advice, which is 165 °F. For thermal calculations, scientists usually move to kelvin when a formula needs absolute temperature, such as in gas laws or radiation, and stay in Celsius when only differences matter.
Mistakes that produce wrong answers
The most common error is using the Celsius number in an equation that needs absolute temperature. The ideal gas law at 25 °C needs 298.15 K, not 25, and using 25 would give nonsense. A second error is doubling a temperature: 20 °C is not half as hot as 40 °C, because the scale has an arbitrary zero. A third is converting a difference with the offset, such as turning a 10 °C rise into 50 °F instead of 18 °F. A fourth is mixing degree Celsius and degree Fahrenheit slopes: a 5 °C step is 9 °F, so one Celsius degree is 1.8 Fahrenheit degrees. Writing the reading and change cases separately in a calculation avoids all four mistakes.
Measurement, precision and reporting
A thermometer reports a reading with an uncertainty, and the number of digits should reflect it. A household thermometer may be good to 0.5 °C, a laboratory platinum resistance thermometer to a few millikelvin after calibration. The International Temperature Scale of 1990, ITS-90, defines how thermometers are calibrated against fixed points such as the triple point of water, and since the 2019 redefinition it remains the practical scale for most work. Converting 36.6 °C to Fahrenheit gives 97.88 °F, but reporting it as 97.9 °F keeps the same precision, and reporting 97.88 °F suggests more certainty than the original reading had. Round after converting, and keep the number of significant digits of the source.
Precision and checking
- Keep the original reading precision.
- Do not add the reading offset to a temperature interval.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Temperature converter
- Celsius to Rankine converter
- Celsius to Kelvin converter
- Celsius to Fahrenheit converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.
Sources
- NIST / BIPM: NIST: unit conversion factors ↗ · 2026-10-08