Measurement basis
Absolute temperature readings and temperature differences use different treatment of offsets. A scale change must preserve which quantity the source actually states.
Definition conventions
Temperature scales use both scaling and offsets. Absolute temperature cannot be below zero kelvin.
Conversion method
For a reading, apply the source and target scale relationships including their zero points. For a temperature difference, use the scale factor without a zero-point offset.
Choose the conversion direction
Determine whether the source is a reading or a difference before choosing the conversion direction.
The kelvin and the Boltzmann constant
The kelvin, symbol K, is the SI base unit of thermodynamic temperature. Since 20 May 2019 it has been defined by fixing the Boltzmann constant at exactly 1.380649 × 10^-23 J/K. Earlier, from 1954, the kelvin was 1/273.16 of the thermodynamic temperature of the triple point of water. The scale is named for William Thomson, Lord Kelvin, who proposed an absolute scale in 1848. Zero kelvin is absolute zero, where thermal motion reaches its minimum. The unit is written K with no degree sign, so 300 K and not 300 °K, and temperatures expressed in kelvin are never negative.
Celsius and its offset
The degree Celsius has the same size as the kelvin, and the scales differ by an offset: T(K) = t(°C) + 273.15. Zero degrees Celsius is 273.15 K, so absolute zero is -273.15 °C. Anders Celsius proposed a centigrade scale in 1742, and his original numbering was inverted, with 0 for boiling and 100 for freezing. The scale was later reversed. On the ITS-90 scale, water boils at about 99.97 °C at standard atmospheric pressure, and since the 2019 redefinition the triple point of water is a measured value of about 273.16 K, or 0.01 °C, and not a defined one. Room temperature of 20 °C is 293.15 K.
Fahrenheit and Rankine
The Fahrenheit scale, devised by Daniel Gabriel Fahrenheit in the early 1700s, gives water freezing near 32 °F and boiling near 212 °F, a span of 180 degrees. The conversion is °F = °C × 9/5 + 32. So 37 °C is 98.6 °F, 100 °C is 212 °F, and 350 °F is (350 − 32) × 5/9 = 176.67 °C. The Rankine scale uses Fahrenheit-size degrees from absolute zero, so °R = K × 9/5 and °R = °F + 459.67. Absolute zero is 0 °R, −459.67 °F and −273.15 °C. Rankine appears in some United States engineering thermodynamics, and its absolute nature makes gas-law calculations work without an offset.
Points versus intervals
A temperature reading and a temperature difference convert differently. A reading goes through the offset formulas. A difference needs only the scale factor. A rise of 10 °C is a rise of 10 K and a rise of 18 °F. Warming from 20 °C to 30 °C is therefore a change of 18 °F, though 20 °C is 68 °F and 30 °C is 86 °F. Using the full formula on a difference, converting 10 °C as if it were a reading to get 50 °F, is a common error. The same distinction applies in thermal quantities such as J/(kg·K), where the denominator is an interval and no offset is used.
Anchors worth remembering
Several reference values help in checking conversions. Water freezes at 0 °C, 273.15 K and 32 °F. Normal body temperature is about 37 °C, or 98.6 °F. Liquid nitrogen boils at 77.36 K, about −195.8 °C. The surface of the Sun is near 5772 K on the nominal effective scale used by the IAU. The cosmic microwave background is 2.725 K. At −40, Celsius and Fahrenheit give the same number. A value that looks wrong after conversion usually fails one of these anchors, such as a body temperature that comes out at 310 °F instead of 310 K.
Practical scales: ITS-90
The kelvin is defined through a fundamental constant, but thermometers are calibrated on the International Temperature Scale of 1990, ITS-90, which assigns temperatures to reproducible fixed points such as the triple point of water, the melting point of gallium at 29.7646 °C and the freezing point of zinc at 419.527 °C. Between fixed points, standard platinum resistance thermometers interpolate. The difference between ITS-90 and true thermodynamic temperature is well under a hundredth of a degree near room temperature and larger at extremes. The converter performs exact scale arithmetic and does not model any instrument.
Everyday and extreme values
Household ovens run at 175 to 250 °C, or 350 to 480 °F, and a refrigerator at about 3 to 4 °C. A hot summer day of 38 °C is 100.4 °F. A freezer at −18 °C is −0.4 °F. Aircraft cruise outside air at about −55 °C, or 218 K. Tungsten melts at 3422 °C, and the plasma in fusion devices exceeds 10^8 K. The kelvin and the Celsius scale agree in size, so large values in kelvin look like Celsius values with 273 added. At 10^8 K the offset of 273 is negligible, and the distinction only matters for everyday temperatures.
Negative temperatures and misused symbols
Negative numbers on Celsius and Fahrenheit scales are ordinary. Below zero kelvin cannot occur for a system in ordinary thermal equilibrium, although physicists describe special systems with population inversion by negative temperature, which are hotter than any positive temperature and not colder than absolute zero. Writing conventions: the symbol K for kelvin takes no degree sign, and degree Celsius is °C with a space between the number and the sign, as in 25 °C. The minus sign should be a true minus, as in −5 °C. Lowercase k is kilo and cannot stand for kelvin, so 300 k would read as 300 kilo-something.
Cooking and weather conversions
Recipes and forecasts cross the scales constantly. A cake baked at 350 °F goes into an oven set to 175 °C on many metric ovens, a rounded figure for the exact 176.67 °C. A forecast low of 5 °C is 41 °F, a high of 25 °C is 77 °F. A quick estimate takes the Celsius value, doubles it and adds 30, giving 80 for 25 °C, which is within 3 degrees of the true 77 °F in the usual weather range. Exact conversions use the 9/5 factor and the 32 offset, and the estimate drifts at the extremes: for 0 °C it gives 30 °F against a true 32 °F, and for 35 °C it gives 100 °F against a true 95 °F. Gas ovens in some countries use numbered marks instead of degrees, so a recipe that says mark 4 needs a printed conversion table, which often lists 180 °C or 350 °F. Scientific papers state temperatures in kelvin for physical laws, since the ideal gas law and radiation formulas need an absolute scale, and a Celsius value substituted into them gives a result that is wrong by a large factor.
Precision and checking
- Keep the resolution of the temperature measurement.
- An offset belongs to a scale reading and must not be added to a temperature interval.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Kelvin (K)
Definition, reference values and linked conversions.
Celsius (°C)
Definition, reference values and linked conversions.
Fahrenheit (°F)
Definition, reference values and linked conversions.
Rankine (°R)
Definition, reference values and linked conversions.
Use a working converter
- Temperature converter
- Celsius to Rankine converter
- Fahrenheit to Rankine converter
- Kelvin to Rankine converter
- Rankine to Celsius converter
- Rankine to Fahrenheit converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.
Sources