Why the two units appear together

Magnetic flux in small devices is naturally measured in nanowebers: the flux through a tiny sensor, a recording head or a small search coil. Magnetic flux in larger components, such as transformer cores and motor poles, is measured in milliwebers or webers. A project that connects the two, for example a sensor that picks up the leakage of a power inductor, deals with both scales on one page of specifications. The two prefixes differ by a factor of one million. This page performs the conversion and keeps the quantity unchanged. The weber is the SI unit of magnetic flux, equal to one volt-second. The page does not calculate flux from a field and an area and does not check any equipment rating. It only rewrites a given number in a different unit.

The factor and the default result

A nanoweber is 10^-9 Wb and a milliweber is 10^-3 Wb, so the ratio is 10^6. The page formula is mWb = nWb × 0.000001. With the default input of 10 nWb the result is 0.00001 mWb, which is 1 × 10^-5. A reading of 2,500 nWb converts to 0.0025 mWb, and a reading of 350 nWb converts to 0.00035 mWb. Going the other way, 0.00001 mWb returns 10 nWb. The factor is exact, since both prefixes are defined as powers of ten, and NIST Special Publication 811 lists them. The leading zeros in the answers can cause miscopying, so count them in groups of three: moving from nano to milli is two steps of 1,000, and the decimal point moves six places to the left.

Flux from a small magnet

A concrete picture helps with the size of a nanoweber. Flux equals flux density times area for a uniform field at right angles to the surface. A field of 1 mT through an area of 1 mm², which is 10^-6 m², gives 10^-9 Wb, or 1 nWb. The default of 10 nWb corresponds to 5 mT through 2 mm², because 0.005 T times 0.000002 m² is 10^-8 Wb. A small neodymium magnet may produce a few hundred millitesla at its surface, so flux through a sensor chip of a few square millimeters can be in the microweber range, and a weaker field gives nanowebers. The numbers are examples to show the scale. The actual flux through any real sensor depends on its orientation, its distance from the magnet and the shape of the field, which the converter cannot know.

Faraday's law and voltages from tiny flux changes

The voltage induced in a coil is the number of turns times the rate of change of flux. A change of 10 nWb in 1 millisecond in a single turn induces an average of 10 microvolts, because 10^-8 Wb divided by 10^-3 s is 10^-5 V. With 100 turns, the induced voltage is 1 mV. A change of 10 nWb in 0.1 ms through the same 100-turn coil gives 10 mV. These are the signals that search coils and pickup coils deliver, and they are the reason flux in nanowebers is a practical unit for small sensors. In the same way a change of 0.00001 mWb is the same flux change in a different unit. The conversion on the page does not alter the physics, and the voltage depends on the time and the turns, not on the prefix chosen.

The maxwell and the flux quantum

The CGS unit of magnetic flux is the maxwell, which equals 10^-8 weber. That makes 1 maxwell exactly 10 nanowebers, so the default 10 nWb is 1 Mx. The converter lists maxwells, so a value from an older source can be moved to nanowebers or milliwebers. At the smallest scale, the flux through a superconducting loop is quantized in units of h divided by 2e, about 2.0678 × 10^-15 Wb. A flux of 10 nWb contains about 4.84 million flux quanta, since 10^-8 divided by 2.0678 × 10^-15 is 4.836 × 10^6. A superconducting quantum interference device, or SQUID, can resolve a small fraction of a flux quantum. These numbers connect the nanoweber to quantum physics and show how fine the scale is.

A second example: geomagnetic flux through a small loop

The Earth's field of around 50 µT passing through a loop of area 1 cm², which is 10^-4 m², carries 50 × 10^-6 × 10^-4 = 5 × 10^-9 Wb, or 5 nWb, when the field is perpendicular to the loop. In milliwebers that is 0.000005 mWb. Rotating the loop by 90 degrees brings the flux to zero. A 100-turn coil would therefore link 500 nWb of flux-turns. These values describe the signal available to a simple compass coil or a search coil magnetometer, and they show why amplifiers with high gain are needed. The numbers are illustrative, and the true field varies with location and time. The converter plays no part in estimating them. It enables you to express the answer in the unit that the next stage of the calculation requires.

Flux linkage and turns

Many data sheets and textbooks quote flux linkage, which is the flux multiplied by the number of turns it passes through, and the unit is still the weber, sometimes called weber-turn. An inductor with 200 turns and a core flux of 3,500 nWb has a flux linkage of 700,000 nWb-turns, which is 0.7 mWb-turns. Inductance is the flux linkage divided by the current, so a current of 0.5 A with that flux linkage gives 1.4 mH. These relations are standard and they show where the milliweber enters in practical design. The conversion of the core flux, 3,500 nWb, is 0.0035 mWb. Be careful with the distinction between flux and flux linkage, because a data sheet that lists one under the heading of the other can introduce an error of the number of turns.

Reading the output

The result 0.00001 is a decimal with four zeros after the point before the 1, and it can also appear as 1e-5 in software. If you are entering the number into a simulation or a report, keep the exponent form to avoid dropping a zero. Choose the unit that gives a convenient number: for 10 nWb, the nanoweber or the microweber (0.01 µWb) are both easier to read than 0.00001 mWb. The milliweber is the better choice when you compare against a larger component, such as a core with a rated flux of 0.5 mWb. In that case it is helpful to see that the sensor flux is 0.00001 mWb, 50,000 times smaller than the core rating. The ratio does not depend on the unit, and it helps to decide whether one effect matters next to the other.

Common mistakes

The most common error is a factor of 1,000 between the micro and nano steps, which gives a result that is off by that factor. Remember the whole route has two steps: nano to micro and micro to milli. A second error is to confuse webers with teslas or gauss, which describe flux density. A third error is a case mistake in the symbol: Wb is the weber, and the symbol Mx belongs to the maxwell. A fourth is to ignore the angle between the field and the surface, which can reduce the flux to a fraction of the maximum. A fifth is to confuse flux with flux linkage. The converter changes the unit only, and each of these issues must be handled before the number is entered.

Magnetic recording and read heads

Magnetic storage devices depend on the flux from small regions of recorded media. A read head senses the field of tiny bits, and the flux through its sensing element is far below a microweber. A field of 10 mT through a sensing area of 0.01 µm by 0.1 µm, which is 10^-15 m², gives 10^-17 Wb, or 10^-8 nWb, much smaller than the 10 nWb default. The comparison shows how small the flux is in nanoscale devices and why they rely on sensitive effects such as magnetoresistance rather than induced voltage. These numbers are order-of-magnitude arithmetic for illustration. The real sensor dimensions, fields and signal chains differ between products, and the converter has no knowledge of them. It supports the arithmetic of moving a flux value between prefixes.

Transformer and inductor core flux

At the other end, power transformers and inductors work with fluxes in the milliweber range and higher. A core with an effective cross-sectional area of 5 cm², which is 5 × 10^-4 m², operating at 1.2 T carries 6 × 10^-4 Wb, or 0.6 mWb. A small inductor core of 25 mm² at 0.3 T carries 7.5 × 10^-6 Wb, which is 0.0075 mWb, or 7,500 nWb when written out in nanowebers. The design rule is that the peak flux density must stay below the saturation value of the core material with some margin, so designers check flux and density together. The converter lets you put a sensor flux of a few nanowebers and a core flux of a few milliwebers on one scale, and the ratio between them shows how weak the leakage field is compared with the main flux.

Scope and sources

The page converts a known magnetic flux between SI-prefixed units and does not calculate flux from field and area. It does not calculate installation limits, equipment ratings, protection, material response or compliance. The weber, the maxwell relation and the prefixes come from the BIPM SI Brochure and NIST Special Publication 811. For design work, rely on the data sheet of the component and the standards that govern the application, and use the converter for the scale change only.