Flux values from small cores and magnets

Magnetic flux is the total field passing through an area, and for small components it is a tiny number in webers. A ferrite core in a switching supply, a magnet in a sensor and the pickup coil of a fluxmeter work with values in the range of nanowebers to microwebers. Data sheets and lab notes switch between the two units depending on size, so a technician who compares a core rating with a measured value may need both in one unit. This page divides the nanoweber value by 1,000 and gives microwebers. A flux of 4,500 nWb becomes 4.5 µWb, and 250 nWb becomes 0.25 µWb. Technicians who compare a core data sheet with a bench reading, and students who check a lab calculation, meet this step often, and one clear conversion keeps the notes consistent.

One step of 1,000

Nano is 10^-9 and micro is 10^-6, so a microweber holds 1,000 nanowebers. The page applies µWb = nWb × 0.001. The SI fixes both prefixes, which makes the step of 1,000 exact. By hand, move the decimal point three places to the left, so 60 nWb is 0.06 µWb. For the reverse conversion, multiply by 1,000, so 12 µWb is 12,000 nWb. The weber itself is one volt-second, which ties flux to the voltage a coil develops when the flux changes. An answer larger than the input points to swapped menus.

Ten nanowebers as 0.01 microweber

The default of 10 nWb returns 0.01 µWb. A larger input of 4,500 nWb gives 4.5 µWb, and 150,000 nWb gives 150 µWb. The lowest value is far below what a small magnet delivers through a coil, so it appears in noise figures and in resolution specifications rather than in a magnet rating. Choosing microwebers keeps most flux values of small cores between 0.1 and 1,000, which is easy to read. If you work with a mix of values, convert the whole column with the page and mark the header with the unit, so a reader does not need to guess. Where a value falls close to a limit in the data sheet, keep the digits and round only at the end, since rounding early can push a design just over a threshold.

A ferrite core and its flux

Flux through a core is the flux density times the cross-section. A core with an area of 0.5 cm², which is 5 × 10^-5 m², carrying a density of 0.2 T holds 1 × 10^-5 Wb. That is 10 µWb, or 10,000 nWb. Designers of small inductors and transformers keep the flux density below the saturation level of the material, which for common ferrites is a few tenths of a tesla, and the data sheet of the core gives the figure. Expressing the flux in microwebers makes the numbers easier to compare with the flux linkage of the winding. The page converts the unit and does not check the core against saturation.

Induced voltage in a transformer winding

For a sinusoidal flux, the RMS voltage across a winding is about 4.44 times the frequency, times the number of turns, times the peak flux. A small transformer winding of 500 turns at 50 Hz with a peak flux of 10 µWb has an RMS voltage near 4.44 × 50 × 500 × 0.00001, which is about 1.1 V. Doubling the flux doubles the voltage. This relation is why core size and flux go together in design, and it gives a feel for why microweber-scale flux is enough for low-voltage windings. Use the page to move between the unit of the core data sheet and the unit used in the formula, then do the multiplication yourself. Remember that the formula uses the peak flux, so if your instrument reports an RMS or an average value, convert it to the peak first according to the instrument manual.

Reading a fluxmeter

A fluxmeter integrates the voltage from a search coil and shows the change in flux linkage. A reading in nanowebers suits small changes, such as moving a magnet near a coil, and microwebers suit larger ones. If the display shows 2,400 nWb and the lab report asks for microwebers, the answer is 2.4 µWb. Check whether the instrument reports flux or flux linkage, which is flux multiplied by the number of turns of the search coil. If the manual says weber-turns, divide by the turns to get the flux. The page converts the value you type and does not know which of the two your instrument displays. When two reports disagree by a whole number of turns, this is the first thing to check, followed by the coil geometry.

Back to nanowebers

To go from microwebers to nanowebers, select microwebers as the From unit and nanowebers as the To unit. Going back means a factor of 1,000 in the other direction. A flux of 2.2 µWb is 2,200 nWb, and a flux of 50 µWb is 50,000 nWb. The reverse direction is handy when a design spreadsheet stores flux in the smallest unit to avoid decimals, and you want to compare a few values with the data sheet. A spot check with three or four rows can reveal a column that was scaled twice. Because the step is a single factor of 1,000, errors usually appear as results that are off by exactly that factor.

Other flux units on the list

The menu offers webers, milliwebers, microwebers, nanowebers, picowebers and maxwells. One microweber is 0.001 mWb, 1,000 nWb, 1,000,000 pWb and 100 Mx, since a maxwell is 10^-8 Wb. When a document mixes SI and CGS values, converting everything to one unit before comparing saves time. The tesla and the gauss describe flux density, which is flux per unit area, and are different quantities from the weber, so a conversion between them needs an area. Keep that distinction in mind when you read a magnet sheet that lists both a flux and a field, since the two numbers answer different questions. The flux of a magnet depends on the pole area you assume, so ask what area the supplier used.

Core data sheets and calibrated probes settle design questions

A microweber figure is a restated reading. It does not compute flux from a field and an area, size a core, find the voltage in a winding or check a measurement. Real values depend on the material, temperature, air gaps and the position of the probe. For design and safety decisions, use the component data sheets, the standards for your product and a measurement made with a calibrated instrument. Quote the part number and the probe model next to the figure, so that a reader can find the data sheet and the calibration certificate that stand behind the number.