What the conversion is for

Magnetic flux is reported in two unit systems that coexist in the literature. Modern papers, standards and instrument manuals use the weber from the SI. Older textbooks, some magnetic recording references and parts of the geophysics and materials literature still use the maxwell from the CGS electromagnetic system. This page converts between them and across the SI prefixes: webers, milliwebers, microwebers, nanowebers and picowebers, plus the maxwell. The default converts 10 pWb into maxwells and returns 0.001 Mx. A picoweber is a very small flux, so the case most readers meet is a small flux in a modern instrument that has to be compared with a value in an older publication. The conversion is exact because the maxwell is defined as 1e-8 Wb, and the page applies that fixed relation to the number you enter.

Weber and maxwell defined

The weber is the SI unit of magnetic flux. One weber equals one volt-second, and it also equals one tesla times one square meter. The unit honors Wilhelm Weber, the German physicist who worked on electromagnetism with Carl Friedrich Gauss. The maxwell is the CGS unit of flux, named after James Clerk Maxwell, and it equals one gauss times one square centimeter. Because 1 T is 10,000 G and 1 m² is 10,000 cm², one weber is 1e8 maxwells, and one maxwell is 1e-8 Wb. The older name for the maxwell was the line, as in the idea of lines of force. NIST Special Publication 811 lists the maxwell among the non-SI units with exact SI equivalents. Since the factor is exact, no measurement uncertainty enters the conversion itself, and any uncertainty in the result comes from the flux value you supply.

Working out the factor

The formula Mx = pWb × 1e-4 comes from two steps. A picoweber is 1e-12 Wb. A maxwell is 1e-8 Wb, so one weber is 1e8 Mx. Multiplying, 1 pWb equals 1e-12 × 1e8, or 1e-4 Mx. With the default value of 10 pWb, the product is 10 × 1e-4 = 0.001 Mx. In reverse, one maxwell is 10,000 pWb, so 0.5 Mx is 5,000 pWb. The page also handles the larger prefixes. One nanoweber is 1e-9 Wb, which is 0.1 Mx. One microweber is 1e-6 Wb, or 100 Mx, and one milliweber is 1e-3 Wb, or 100,000 Mx. Remembering that 1 µWb is 100 Mx is a handy anchor for rough checks, because many small coil and sensor fluxes land in the micro or nanoweber range.

Gauss, tesla and the area behind the flux

Flux is field strength times area, so a conversion of flux alone says nothing about the field. A flux density of 1 gauss passing through 1 cm² carries 1 Mx. Earth's magnetic field at the surface is roughly 0.25 to 0.65 G depending on location, so a 1 cm² loop facing it captures about 0.25 to 0.65 Mx, which is 2,500 to 6,500 pWb. This is a useful way to get a feel for the numbers. Reaching a picoweber needs a flux density of only 1e-4 gauss, or 10 nT, through 1 cm², or a stronger field through a tiny area. A 1 mm² area in a 1 mT (10 G) field carries 1e-9 Wb, which is 1 nWb. When a datasheet gives field in gauss and an area in square centimeters, the product is already in maxwells, and this page then moves that result into SI.

Flux in superconducting devices

Quantum devices bring picoweber-scale and smaller fluxes into daily use. The magnetic flux quantum in a superconducting loop is h divided by 2e, about 2.0678e-15 Wb, which is roughly 2.07 femtowebers. That is 0.002 pWb, or 2.07e-7 Mx. SQUID magnetometers detect changes of a small fraction of this quantum, which makes them among the most sensitive flux detectors available. Papers on these devices usually quote flux in units of Φ0 or in webers, while older low-temperature physics references may use maxwells. If you read a loop-area calculation that gives a flux of 5e-3 Mx, converting to webers gives 5e-11 Wb, or 50 pWb, which is about 24,000 flux quanta. This page makes the first step of such a comparison, and the division by the flux quantum is yours to do. The numbers here are illustrative, and the flux quantum value is the CODATA-based one from the 2019 SI constants.

Magnetic recording and coils

Magnetic recording heads, pickup coils and search coils are described through flux linkage. A search coil with N turns responds to the rate of change of flux through each turn, so the induced voltage equals N times dΦ/dt, in volts when Φ is in webers and t in seconds. A coil of 200 turns exposed to a flux that changes by 5 µWb in 1 ms produces 200 × 5e-6 / 1e-3 = 1 V. If an old paper gives that flux change as 500 Mx, the conversion gives 5e-6 Wb, and the same voltage results. Mixed units are where mistakes enter. A volt equals a weber per second, whereas a CGS abvolt equals a maxwell per second, and the abvolt is 1e-8 V. Keep a single system for the whole calculation, convert the flux input once with this page, and use SI for everything after.

A second worked example

A test report lists the flux linking a small sensing loop as 2,500 pWb and an older reference sheet for comparison lists thresholds in maxwells. Multiply by 1e-4: 2,500 × 1e-4 equals 0.25 Mx. That equals 2.5e-9 Wb, or 2.5 nWb, and it is the flux that a 0.25 G field would produce through 1 cm². Now take the reverse. A CGS source says a recording head gap carries 0.5 Mx. Entering 0.5 with maxwells as the source and picowebers as the target gives 5,000 pWb, which is 5 nWb. In both examples the physical flux is identical before and after; only the unit label changes. A fast check is that a maxwell is a much smaller unit than a weber but a much larger unit than a picoweber, so converting from pWb to Mx must reduce the number by a factor of 10,000. These numbers are illustrative rather than measurements.

Reading the output

Small fluxes in maxwells come out as decimals with several leading zeros. The default 0.001 Mx shows three zeros, and 10 fWb would show more. If you move to webers the exponents grow, and the result may appear in exponent notation, such as 1e-11 Wb for the default flux. Both forms are exact representations of the same number. The page does not round to a fixed number of decimal places, so you can see how many significant digits the conversion carries, though your measured value is rarely that precise. If you report the result, round to the number of significant digits in the input. A flux measured as 10 pWb with two significant digits should be reported as 0.0010 Mx, not as a long string. Pick the output unit that gives a convenient number. Maxwells suit a few thousand picowebers, and nanowebers suit values that would otherwise need many zeros.

What the page does not do

The conversion assumes the entered quantity is magnetic flux. Magnetic flux density is a different quantity, with tesla and gauss as its units, and flux per turn or flux linkage differs from flux by the number of turns. The page does not convert between them, since that needs an area or a turn count. It also does not model materials, saturation, demagnetization, leakage flux or the response of any sensor, and it does not calculate installation limits, equipment ratings, protection, material response or compliance. Treat the output as the same flux written in a different unit. When a document uses unusual conventions, such as flux in kilolines, one kiloline is 1,000 Mx, or 1e-5 Wb, and you will need that bridging step before using the converter.

Faraday induction and what a picoweber does

Flux matters in practice through Faraday's law: the voltage induced in a loop is the rate of change of flux through it. A flux change of 10 pWb in 1 µs induces 1e-11 / 1e-6 = 1e-5 V, which is 10 µV in a single turn. The same change spread over a millisecond gives only 10 nV. This is why the time scale of a measurement decides whether a picoweber-scale flux is detectable at all. Pickup coils with many turns multiply the signal by the turn count. A 1,000-turn coil sees 10 mV from the 1 µs example. In older CGS sources the same law appears with the abvolt, defined as one maxwell per second, and an abvolt is 1e-8 V. If you meet an induced voltage in abvolts alongside a flux in maxwells, convert both to SI before comparing against a modern amplifier input range.

Unit names and symbols

Symbols are short and easy to confuse. The weber is Wb, with a capital W for Weber and a lowercase b, and the picoweber is pWb. The maxwell is Mx. The CGS system exists in electrostatic, electromagnetic and Gaussian versions, and the maxwell belongs to the electromagnetic and Gaussian ones, where magnetic flux density is in gauss and field strength is in oersted. SI field strength is in amperes per meter, and the relation between oersted and A/m is a factor of 1000/4π, which is a different conversion that this page does not cover. A frequent slip is using the tesla where flux is wanted, or the weber where density is wanted. One tesla is one weber per square meter. If the quantity in your source has an area in its unit, such as Wb/m² or Mx/cm², it is flux density, and you should not convert it with this page.