Why two unit systems coexist
Handheld conductivity meters, aquarium testers and many laboratory instruments display microsiemens per centimeter, a unit that follows from the centimeter-sized electrodes in the probe. Scientific papers, standards and many European water agencies report millisiemens per meter or siemens per meter, which are SI units built on the meter. A reading of 10 µS/cm taken in the field therefore has to be restated as 1 mS/m in a report that follows the SI system. This page does that conversion and nothing else. The default input is 10 µS/cm and the result is 1 mS/m, and the page formula is mS/m = µS/cm × 0.1. The factor reflects both a change of prefix, from micro to milli, and a change of length, from centimeter to meter. Keeping both changes in mind helps to understand why the number gets smaller, rather than larger.
Deriving the factor of 0.1
Start with the siemens, the SI unit of electrical conductance, which is the inverse of the ohm. Conductivity is conductance across a unit length and area, so its SI unit is siemens per meter. A micro prefix is 10⁻⁶ and a centimeter is 10⁻² meters. One µS/cm is 10⁻⁶ S divided by 10⁻² m, which equals 10⁻⁴ S/m. A millisiemens is 10⁻³ S, so 10⁻⁴ S/m is 0.1 mS/m. In short, 1 µS/cm equals 0.1 mS/m, and the conversion is exact. A handy way to remember it is that 1 mS/m equals 10 µS/cm. The default input of 10 µS/cm becomes 1 mS/m. For the reverse direction, multiply by 10 instead. The siemens is named after Werner von Siemens, and since 1971 it has been the SI name for what used to be called the mho.
Worked examples with water
The default of 10 µS/cm gives 1 mS/m. A more typical drinking water reading is 250 µS/cm, which gives 25 mS/m. The standard 0.01 M potassium chloride calibration solution is stated to have a conductivity of 1,413 µS/cm at 25 °C, so it corresponds to 141.3 mS/m. A reading of 1,000 µS/cm equals 100 mS/m, and 50,000 µS/cm, which is in the range of seawater, equals 5,000 mS/m or 5 S/m. For very pure water the numbers go the other way, since pure water at 25 °C has a theoretical conductivity of about 0.055 µS/cm, which equals 0.0055 mS/m. The scale is therefore wide, and the factor of 0.1 applies at every point. If you can state what kind of water gave the reading, you can quickly judge whether the converted number is plausible.
Typical conductivity ranges
Conductivity measures how well a solution carries current, and dissolved ions are the cause. Rain and distilled water read at the low end, often a few µS/cm in practice because of absorbed carbon dioxide and trace ions. Fresh surface waters and tap water usually read from tens to a few hundreds of µS/cm, though hard or mineral waters read higher. Brackish water and irrigation water with high salinity read in the thousands. Seawater is about 50,000 µS/cm, or 5 S/m, at 25 °C. In the units of this page, those ranges become fractions of mS/m for pure water, a few mS/m to tens of mS/m for typical fresh water, and hundreds to thousands for brackish and salty water. The European Drinking Water Directive 98/83/EC lists conductivity as an indicator parameter with a value of 2,500 µS/cm at 20 °C, which equals 250 mS/m.
Temperature matters
Conductivity rises with temperature, by about two percent per degree Celsius for many natural waters, because ions move faster in warmer water. Meters therefore report either the raw reading or a value compensated to a reference temperature, most often 25 °C and sometimes 20 °C. A reading of 250 µS/cm at 25 °C is not the same as 250 µS/cm at 20 °C, and the converted 25 mS/m inherits that reference. The unit conversion does not change the reference temperature. When copying a result into a report, include the reference temperature and whether compensation was applied. If the instrument and the report use different references, a separate temperature correction is needed before the unit change. This page does not perform that step, and it does not know which temperature your reading belongs to.
Probe geometry and the cell constant
A conductivity probe measures conductance between electrodes, and the instrument converts it to conductivity using a cell constant, which is the distance between the electrodes divided by their area, expressed in reciprocal centimeters. Many probes have a cell constant of 1.0 cm⁻¹, and others use 0.1 or 10 for low or high conductivity ranges. The meter does the multiplication and displays µS/cm or mS/cm. The cell constant is why the centimeter appears in the unit at all. The SI unit of siemens per meter uses the same physics but expresses length in meters. If you use raw conductance in microsiemens and know the cell constant, the conductivity in µS/cm is the conductance times the cell constant in cm⁻¹. The page starts from conductivity and does not need the cell constant.
Total dissolved solids and why this is not TDS
Many inexpensive meters display total dissolved solids in parts per million, calculated from conductivity using a fixed factor. A common factor is between 0.5 and 0.7 ppm per µS/cm, depending on the dissolved ions, so a 250 µS/cm reading might be shown as about 125 to 175 ppm. This page does not perform such a conversion and does not estimate dissolved solids. It converts conductivity units only. Because the TDS factor depends on the ion mix, a TDS value from a meter is an estimate, and a laboratory analysis is needed when composition matters. If you start with a TDS reading, convert it back to conductivity using the same factor that the meter used, then apply this page. Otherwise the unit change will carry the meter assumption into your report without anyone noticing.
Reporting a converted value
A report that follows the SI system should give conductivity in mS/m or S/m, state the reference temperature and give the number of significant figures supported by the instrument. A handheld meter with a resolution of 1 µS/cm and a reading of 250 gives 25.0 mS/m. If the meter has three significant digits at best, writing 25.00 mS/m is overly precise. Because the factor is exact, the conversion adds no uncertainty. It is useful to keep both the original and the converted value in the working notes, so a reader can follow the arithmetic. Where a regulation, permit or contract sets a limit in one unit, compare the measured value in that unit, to avoid arguments about rounding in the conversion. Use the official source listed on the page for the factors and confirm any compliance question with the governing document.
A mixing and monitoring example
Hobby and field work shows how the numbers move. An aquarium keeper measures tap water at 380 µS/cm, which is 38 mS/m, and reverse osmosis water at 20 µS/cm, which is 2 mS/m. Mixing them in equal volumes gives a conductivity of roughly 200 µS/cm, or 20 mS/m, because dilute solutions mix approximately linearly (the approximation weakens at high concentration or with unusual ion mixes). A stream monitoring program might log a lake outlet at 180 µS/cm, which is 18 mS/m, and a road-salt affected creek in winter at 1,200 µS/cm, which is 120 mS/m. Plotting both on an SI axis in mS/m takes only a division by ten of the field readings. The jump between the two sites is more informative than either number, and a unit change does not alter it. The page performs the division by ten consistently, so the comparison stays free of arithmetic slips, but it cannot say whether a particular value is healthy for an ecosystem.
Meter displays that switch units
Many auto-ranging meters change their display unit as the reading grows. A probe may show 845 µS/cm and then 1.45 mS/cm once the value passes about 2,000 µS/cm, and the two forms are the same measurement in different prefixes. A reading of 1.45 mS/cm is 1,450 µS/cm, and in the SI unit of this page it is 145 mS/m, because one mS/cm equals 100 mS/m. The centimeter in the denominator is the part that people forget when they copy a display value into a report. A quick sanity check is to remember that mS/m values are numerically one hundred times larger than mS/cm values and one tenth as large as µS/cm values. If your converted number does not fit that pattern, look at the unit text on the display before you blame the converter. Enter the number in the same unit the meter showed, choose that unit in the From menu, and let the page apply the factor.
Scope and limits
The converter changes the unit of a conductivity value and assumes that the input is a conductivity already, not a conductance in microsiemens. It does not compensate for temperature, estimate salinity or TDS, judge the safety of water, or check that a meter is calibrated. It also does not know whether a reading is plausible for a given sample. The assumptions on the page note that it does not calculate installation limits, equipment ratings, protection, material response or compliance. The factor follows the SI definition of the siemens and prefixes as given by the BIPM and in NIST SP 811. For water quality decisions, rely on calibrated instruments and the guidance of the relevant authority.