Reading low-conductivity data
Pure and nearly pure waters have conductivities so small that the millisiemens scale gives awkward decimals. A reading of 0.8 mS/m is easier to handle as 800 µS/m, and a laboratory limit stated as 1,500 µS/m is easier to compare with a probe that shows 1.5 mS/m. This page multiplies the mS/m value by 1,000 and returns the same conductivity in µS/m. The meter stays in the denominator on both sides, so no length factor is involved. It is the plain prefix step, useful when two data sources use neighboring prefixes of the same SI unit and a spreadsheet needs a single column that both can feed.
One thousand, nothing more
The prefix milli is 10^-3 and micro is 10^-6, so one millisiemens is 1,000 microsiemens, and the formula is µS/m = mS/m × 1,000. The siemens is the SI unit of conductance, one ampere per volt, as listed by the BIPM SI Brochure and NIST SP 811. The factor is defined, so the conversion has no uncertainty. To check by hand, move the decimal point three places to the right: 25 mS/m becomes 25,000 µS/m, and 0.5 mS/m becomes 500 µS/m. The result is always a larger number than the input, because the target unit is smaller. If your result is smaller, the menus are likely reversed.
Ten mS/m in µS/m
The default of 10 mS/m returns 10,000 µS/m. In per-centimeter terms that is 100 µS/cm, a moderate conductivity for natural fresh water. A conversion between per-meter and per-centimeter figures is a separate step, since 1 µS/cm equals 100 µS/m. For orientation, 10 mS/m is 0.01 S/m, which corresponds to a resistivity of 100 ohm-meters. That figure is a common order of magnitude for moist soil and also for fresh groundwater. The numbers are illustrative anchors for reading the default result, offered so that you can tell a plausible output from a slipped decimal, and a given soil or water can be far above or below them depending on its moisture, clay content and dissolved salts.
Water samples reported per meter
Several international water-quality methods express conductivity in mS/m at 25 °C. A laboratory report might list a tap water sample at 40 mS/m. In µS/m that is 40,000, and in the per-centimeter style used by many handheld meters it is 400 µS/cm. A rainwater sample could lie near 2 to 5 mS/m, which is 2,000 to 5,000 µS/m, but the range depends on location and the sampling method, so treat it as a rough guide. A sample of distilled water kept in an open beaker can climb from under 1 mS/m to several mS/m within hours as it absorbs carbon dioxide. Use the page to put a whole table into one unit before computing averages or plotting, and convert the individual values rather than an average of mixed units. Mixing mS/m and µS/m in one column produces averages that are meaningless, and the error is hard to see in a chart.
Ground and rock conductivity surveys
Instruments for electromagnetic induction surveys report apparent conductivity in mS/m. Values of a few mS/m suggest dry sand or resistive rock, and values of tens to hundreds of mS/m suggest clay or saline ground. Some data processing programs want µS/m, in which case a survey value of 35 mS/m becomes 35,000 µS/m. The apparent conductivity is a weighted average over a volume of ground, so it is not the conductivity of any single layer. The page only changes the unit and cannot tell you what the number means in the ground, and two surveys with different coil spacing or instrument height should not be merged without checking the manufacturer notes. Keep the instrument settings with the data file, since they affect how a reading should be interpreted.
Converting µS/m to mS/m
To go the other way, select µS/m as the source and mS/m as the target. A value of 5,000 µS/m equals 5 mS/m, and 800 µS/m equals 0.8 mS/m. Divide by 1,000. When the number in µS/m has many digits, group them in threes so that the thousands separator marks the milli step: 25,000 reads as 25 thousand micro, which is 25 milli. Some instruments display µS/m with a decimal point that is easy to miss on a small screen. Compare the result with the other units your data uses, such as µS/cm, where the same water would show a number 100 times smaller than in µS/m.
Precision and significant digits
The factor adds no uncertainty, so the converted value has the same significant digits as the input. A conductivity probe may be accurate to about one percent of the reading plus a small offset, and low-conductivity water is the hardest case because absorbed carbon dioxide raises the reading within minutes of exposure to air. Reporting 800 µS/m for a reading of 0.8 mS/m keeps the digits honest, while 800.00 suggests more precision than the probe had. Use enough digits to keep sample differences visible and no more, and always carry the unit with the number in the table. When a report gives a result with an uncertainty, apply the same factor to the uncertainty, so that 40 ± 2 mS/m becomes 40,000 ± 2,000 µS/m, and keep the two numbers in the same unit.
Comparing with per-centimeter tables
Many reference tables list conductivity per centimeter. To compare them with per-meter data, remember that a per-centimeter number is 100 times smaller than the per-meter number with the same prefix. A value of 100 µS/cm is 10,000 µS/m, and 10 mS/m is 100 µS/cm. Convert prefix and length in separate steps if you do it by hand, and use the dedicated per-centimeter converter when both change at once. Writing the conversion in two lines in your notes lets a reviewer verify each factor on its own. For example, 400 µS/cm first becomes 0.4 mS/cm and then 40 mS/m, and the product of the two steps matches the single factor of 0.1 between µS/cm and mS/m. Review the notes before data is released.
Meter calibration and the µS/m reading
The page changes the prefix of a conductivity. It does not adjust for temperature, estimate dissolved solids, interpret a survey or check compliance with a rule. For those tasks use the method standard, the instrument manual and the guidance of the agency that owns the data.