From the probe display to the SI unit

A conductivity probe says mS/cm. A finite-element model, a physics textbook or an engineering standard says S/m. The page connects the two. Type the probe value, keep S/m as the target and read the number that goes into the model. Both unit changes happen at once, the milli prefix and the move from centimeters to meters, and the combined factor is one tenth. People who need this include students running an electrostatics or electromagnetics simulation with a conductivity from a lab sample, technicians matching a sensor sheet to a design specification, and anyone reading a paper that lists material properties in SI units only. The page does not measure or simulate anything. It restates a conductivity in another unit.

Two steps that multiply to one tenth

First the prefix: 1 mS is 0.001 S. Then the length: 1 cm is 0.01 m, so a quantity per centimeter is 100 times larger when written per meter. The product of 0.001 and 100 is 0.1, so S/m = mS/cm × 0.1, or divide by 10. A conductivity of 1 mS/cm therefore equals 0.1 S/m, and 10 mS/cm equals 1 S/m. Both factors come from the definitions of the prefixes and the meter, so the conversion is not subject to measurement uncertainty. The usual error is applying only one of the two, which produces a result off by a factor of 100 or 1,000, and a simple check with 1 mS/cm equal to 0.1 S/m catches it. Another useful anchor is that 100 mS/cm equals 10 S/m, so a probe that shows three digits before the decimal point is measuring something far more conductive than drinking water.

Ten mS/cm equals one S/m

With the default of 10 mS/cm, the page returns 1 S/m. The round result is a convenient anchor: ten times the input moves the decimal one place. Other conversions follow from it. Physiological saline of 0.9 percent sodium chloride conducts at roughly 1.5 S/m near room temperature, which would read about 15 mS/cm on a probe. Seawater at about 5 S/m reads near 50 mS/cm. Drinking water at 0.5 mS/cm is 0.05 S/m, and a calibration standard of 1.413 mS/cm is 0.1413 S/m. The saline and seawater figures are approximate and vary with temperature and composition, so use them as orientation and take exact values from your own measurement.

Metals sit far above water

Putting water next to metals shows the scale of the SI unit. Annealed copper, the reference for the IACS conductivity scale, has a conductivity of about 5.8 × 10^7 S/m, which is 5.8 × 10^8 mS/cm. A solution at 1 S/m therefore conducts roughly 58 million times less than copper. In a simulation that contains both, the huge ratio can cause numerical trouble, and modelers sometimes treat the metal as an ideal conductor. The page handles only the unit step. If you enter a value for a metal in mS/cm, the output will be an enormous number, and the S/m form is the easier one to compare with tables in physics references. For a sense of scale, a typical stainless steel is near 1.4 × 10^6 S/m, still about a million times above a strong salt solution, so simulations that mix electrolytes and steel parts need conductivities entered in one consistent unit throughout.

Tissue and body-contact modeling

Biomedical modeling of electrodes, stimulation and heating uses tissue conductivities in S/m. Published tables give blood and muscle values on the order of a few tenths to about one S/m at low frequencies, and fat and bone much lower. Conductivity also depends on frequency, so the table must match the frequency of the simulation. If a lab measures a saline phantom with a probe and gets 8.5 mS/cm, the number for the model is 0.85 S/m. The page does the unit step only and does not supply tissue data or judge whether a phantom matches real tissue. Use the published databases and the standards of your field for the properties themselves.

Back from S/m to mS/cm

To convert in the other direction, choose S/m as the source and mS/cm as the target. A value of 1 S/m equals 10 mS/cm, 0.05 S/m equals 0.5 mS/cm and 5 S/m equals 50 mS/cm. Multiply by 10. This is the route for checking whether a model parameter matches the range of a probe: a probe that tops out at 200 mS/cm can read up to 20 S/m, so a material at 30 S/m is out of its range. Writing the instrument range in both units in your notes helps when you hand data between a lab person and a modeler who each think in their own unit.

Resistivity is the reciprocal

Conductivity in S/m is the reciprocal of resistivity in ohm-meters. A solution of 1 S/m has a resistivity of 1 ohm-meter, and one at 0.1 S/m has 10 ohm-meters. Soil and groundwater surveys, and grounding designs, quote resistivity, while chemistry uses conductivity. The page gives the conductivity side. Take the S/m value and invert it yourself for ohm-meters. For example, 0.1413 S/m inverts to about 7.08 ohm-meters. Keep the quantity name in column headers, because a number without a name could be either one, and the two move in opposite directions when the solution gets saltier.

Temperature and frequency for a model input

A conductivity value belongs to a temperature, usually 25 °C for water meters, and for tissue and other materials to a frequency as well. The conversion preserves both unchanged. If a model runs at a different temperature than the sample was measured at, correct the value with the temperature coefficient suited to your material before you convert or after, since the order does not matter for a pure scale factor. Record the conditions with the number so the model input can be traced to its source. Many simulation packages also ask for the unit system in a global setting, and a model set up in millimeters needs conductivity in S/mm or in a scaled form, so check the length unit of the whole model before typing the S/m value.

Resistivity and material limits for S/m

The page moves a cell reading from mS/cm to the S/m used in field models and nothing beyond that. It does not provide material data, run a simulation, compensate for temperature, estimate salinity or decide whether an installation meets a rule. Use the standards of your field and the instrument manual for those decisions.