When the numbers get very small
Siemens per centimeter is the unit of choice in materials science, battery research and semiconductor data, where conductivity is often listed per centimeter because samples are measured in centimeter-sized pieces. Field instruments and sensors that report in µS/m give much larger numbers for the same quantity. A factor of 10^-8 separates the two, so even moderate readings convert to results that need scientific notation. This page does the arithmetic and displays the output so you do not have to count zeros. It is most useful when you compare a measured low conductivity with a published S/cm value for a polymer, a coating or a ceramic.
Building the factor from the prefixes
A microsiemens is 10^-6 siemens. Per meter becomes per centimeter by dividing by 100, since the centimeter is the smaller length and the same conductance spread over a shorter length is less per unit length. Combined, 1 µS/m equals 10^-8 S/cm, so 10 µS/m equals 10^-7 S/cm. In the other direction, 1 S/cm equals 10^8 µS/m, or 100 S/m. These relations follow from the SI prefixes defined by the BIPM and need no measured constant. If you are comfortable with exponents, adding the two shifts is quicker than any rule of thumb.
The default result
The page opens with 10 µS/m, which gives 0.0000001 S/cm, written 1e-7 S/cm in many tables. A value of that size is typical of poorly conducting substances rather than metals or salt water. As another illustration, 500 µS/m gives 0.000005 S/cm and 1,000,000 µS/m gives 0.01 S/cm. The output is long when written out in plain decimals, so copy it carefully or use scientific notation when you paste it into a document. If your report style asks for notation like 5 × 10^-6 S/cm, count the exponent from the converter result.
Antistatic floors, plastics and coatings
Manufacturers of antistatic and dissipative materials describe them with resistivity, volume or surface, in ohm-centimeters or ohms per square, and sometimes with conductivity. A conductivity of 10^-8 S/cm corresponds to a resistivity of 10^8 ohm-centimeters, and the product of the two is always 1. Standards for static control, such as the ESD Association documents, define test methods that report resistance or resistivity, so a conductivity from a supplier may need to be inverted before it can be compared with a test result. Doing the unit conversion first and the inversion second keeps each step easy to check, and it avoids the common slip of inverting a number that is still in the wrong length unit. If a data sheet gives conductivity in S/cm and your test equipment reports in µS/m, convert before comparing. The step is also useful when you read about static control in electronics assembly, where a floor or a mat must fall within a stated range to drain charge safely.
Battery electrolytes and solid ionic conductors
Researchers report the ionic conductivity of battery electrolytes in S/cm, with liquid electrolytes often around 10^-2 S/cm and many solid electrolytes lower. A measurement that comes from a test cell as 100,000 µS/m converts to 0.001 S/cm. Papers and data sheets from different groups mix units, so one comparison table may list S/cm, mS/cm and S/m side by side. The converter helps put measured values and literature values in the same unit. Conductivity of an electrolyte also depends on temperature, so compare values at the same temperature.
Reciprocal view as a sanity check
Resistivity is the reciprocal of conductivity. A value of 10^-7 S/cm corresponds to a resistivity of 10^7 ohm-centimeters, which is 10 megohm-centimeters. A value of 0.01 S/cm corresponds to 100 ohm-centimeters. Turning the conductivity into resistivity is a quick check on whether the magnitude fits the material class you expect. If a plastic sample gives a conductivity near 0.01 S/cm, the sample, the units or the geometry data are probably wrong. A quick glance at the reciprocal catches those errors before they enter a report.
Writing very small numbers well
Documents with S/cm conductivities usually adopt scientific notation or engineering prefixes. Writing 1e-7 S/cm as 0.1 µS/cm is equivalent and sometimes friendlier. The converter on this site lists µS/cm, mS/cm and µS/m so you can pick a unit that avoids long strings of zeros. Choose one style for a table and apply it to every value. Mixing 1e-7 S/cm in one cell and 0.1 µS/cm in another is easy to misread. Note also that µS/cm is a unit with a different base length than the input of this page, so a column labeled only with µS is ambiguous: the reader cannot tell whether the length is the meter or the centimeter. State the full unit, including the length, in every header. Keep units in the column header and avoid abbreviations that vary between sources.
Polymer and coating conductivity depends on conditions
The page converts a given value from one unit to another. It does not compute conductivity from a measured resistance and sample dimensions, and it does not model temperature, frequency or moisture effects, which strongly influence the conductivity of polymers, coatings and electrolytes. It also does not assess whether a material meets a specification. Use the output as a consistent number in the unit your source requires and consult the test standard or the material data sheet for decisions about suitability. A reported value should also carry its measurement frequency when the method uses alternating current, since the response of many ionic materials changes with frequency, and it should state whether the figure is a bulk property or includes contact and interface effects.
Comparing a four-point probe result with a data sheet
In a materials lab, conductivity usually comes from a measured resistance plus the sample geometry, not from a direct reading. Suppose a four-point probe analysis reports 2,000,000 µS/m for a conductive film, which converts to 0.02 S/cm, and a supplier data sheet lists 0.025 S/cm for the same coating. The two values are within the same decade, which suggests normal sample variation, while a data sheet value near 25 S/cm would point to a different material or a wrong unit. Running the conversion first avoids hunting for a problem in the measurement that is really a unit mismatch. Record the film thickness, the temperature and the humidity along with the result, since conductive coatings can respond to all three. Report the converted value with the same number of significant figures as the measurement, not with every digit the converter prints.