Measurement basis
A resistance already in ohms retains its reference value.
Definition conventions
Prefixes use SI decimal powers, and the selections rescale known resistance values only.
Conversion method
Keep Ω unchanged for the reference; divide by another resistance factor to use its prefix.
Reference equivalent of Ω
1 Ω = approximately 1 Ω.
Recorded scale factors: 1 for Ω; 1 for Ω.
Worked example
Known input: 10 Ω. Reference equivalent: 10 Ω. The return conversion gives approximately 10 Ω.
The example preserves a resistance quantity.
Common reference values
| Input (Ω) | Reference equivalent (Ω) |
|---|---|
| 1 | 1 |
| 5 | 5 |
| 10 | 10 |
| 25 | 25 |
| 50 | 50 |
| 100 | 100 |
Compare one Ω with other units
| Target unit | Equivalent of 1 Ω | Definition guide |
|---|---|---|
| Milliohms (mΩ) | 1000 | Read definition |
| Microohms (µΩ) | 1000000 | Read definition |
| Kiloohms (kΩ) | 0.001 | Read definition |
| Megaohms (MΩ) | 0.000001 | Read definition |
| Gigaohms (GΩ) | 1e-9 | Read definition |
| Teraohms (TΩ) | 1e-12 | Read definition |
The ohm and its definition today
The ohm (Ω) is the SI unit of electrical resistance, defined as one volt per ampere, or kg·m²·s⁻³·A⁻² in base units. Since the 2019 SI revision, the ampere is defined by the elementary charge e, and the volt through the Planck constant, so the ohm follows from fixed values of h and e. The von Klitzing constant R_K = h/e² is about 25,812.807 Ω and is exact in the 2019 SI, and the quantum Hall effect, discovered by Klaus von Klitzing in 1980, realizes resistance standards from it. The BIPM SI Brochure lists the ohm among the derived units with special names. The symbol is the Greek capital letter omega, Ω.
From Ohm law to the mercury column
Georg Simon Ohm published the relation between voltage, current and resistance in 1827, and the unit carries his name. As electrical measurement spread in the nineteenth century, standard resistors were needed. The 1881 Paris congress picked the ohm as a practical unit, and a mercury column was used to define it: the international ohm of 1908 was the resistance of a column of mercury 106.300 cm long, of mass 14.4521 g, at 0 °C. Those definitions were replaced by absolute electrical units in 1948, and later by the quantum Hall standard from 1990. A resistor labeled 1 Ω today traces to realizations that differ from the 1908 value by tiny fractions, which the metrology institutes track.
Ohm law with everyday numbers
Ohm law states V = IR. A 5 V supply across a 220 Ω resistor drives I = 5 / 220 = 22.7 mA and dissipates P = V²/R = 25 / 220 = 0.114 W. For an LED that needs 15 mA at a forward voltage of about 2 V on a 5 V supply, the series resistor is (5 − 2) / 0.015 = 200 Ω. Resistors in series add: 100 Ω and 220 Ω give 320 Ω. In parallel they combine as the reciprocal sum, so 100 Ω and 220 Ω give 22,000 / 320 = 68.75 Ω, lower than either. The power rating matters as much as the value, and a resistor of 0.25 W would be hot at 0.114 W. These formulas hold for resistors that follow a linear current-voltage relation.
Prefixes and the site converters
The ohm takes prefixes from micro to tera. One Ω equals 1,000 mΩ, 1,000,000 µΩ, 0.001 kΩ, 0.000001 MΩ and 10^-9 GΩ. The site pages for Ohms to Milliohms, Kiloohms, Megaohms, Microohms and Gigaohms apply these factors, as do the reverse pages and the Teraohms pages. A 4,700 Ω resistor is 4.7 kΩ, 0.0047 MΩ and 4,700,000 mΩ. A current-sense resistor of 0.01 Ω is 10 mΩ. Insulation testers read in megaohms and gigaohms, and the prefix steps are pure powers of 1,000 without rounding. Note that the symbol for mega is an uppercase M and for milli a lowercase m, and a transcription error between mΩ and MΩ is a factor of one billion.
Reading resistor values and codes
Fixed resistors are made in preferred value series: E12 with tolerance around 10 percent, E24 around 5 percent, and E96 around 1 percent. Values such as 1.0, 2.2, 4.7 and 10 recur in each decade. Color bands encode the digits, a multiplier and the tolerance, and surface-mount parts use numeric codes. The IEC 60062 notation places the letter R, k or M where the decimal point would go, so 2R2 is 2.2 Ω, 4k7 is 4.7 kΩ and 1M5 is 1.5 MΩ. This avoids a lost decimal point in a printed list. A resistor tolerance of 5 percent on 1 kΩ means the actual value lies between 950 and 1,050 Ω, and temperature coefficients shift it further, from tens to hundreds of parts per million per kelvin.
Typical resistance values
A short length of heavy wire measures milliohms. A 2 m extension cord of 1.5 mm² copper has a one-way resistance of about 0.023 Ω. A typical household incandescent lamp of 60 W at 120 V has a hot resistance of 240 Ω, and the cold filament has a small fraction of that value. Headphones list impedances from 16 Ω to 600 Ω, an oscilloscope input is commonly 1 MΩ, and radio-frequency systems use characteristic impedances of 50 Ω or 75 Ω. Insulation in good condition measures megaohms to gigaohms. The numbers show that the ohm covers an enormous range, and that prefix choices follow the field. Impedance, a more general quantity, also uses ohms but includes frequency-dependent reactance.
Why small resistances need four wires
Measuring milliohms with two probes includes the resistance of the leads and contacts. A 0.01 Ω current-sense shunt measured through two leads of 0.1 Ω each would read about 0.21 Ω, twenty-one times too high. A four-terminal, or Kelvin, connection sends the current through one pair of leads and senses the voltage with a second pair that carries almost no current, so only the shunt voltage is read: 1 A through 0.01 Ω gives 10 mV. Low-resistance ohmmeters also reverse the current to cancel thermoelectric offsets. The same method applies to any measurement below roughly 1 Ω, and the unit prefix milliohm usually signals that four-wire sensing is in use or should be.
Resistance is not resistivity or conductance
An ohm reading describes a particular object. Resistivity, in ohm meters or ohm centimeters, describes the material, and the two relate through R = ρL/A, so the same material gives different resistances for different shapes. Conductance is the reciprocal, in siemens, so 50 Ω is 0.02 S or 20 mS. Sheet resistance, written in ohms per square, is another variant for thin films. A source label with a length in the unit, such as Ω·m or Ω·cm, signals resistivity. A measurement of 5 Ω across two probes touching a sample includes contact and lead resistance, which is why precision work uses four-terminal sensing to remove those terms from the reading.
Printing the ohm sign and plain-text fallbacks
Use the Greek capital omega, Ω, in print. Some fonts and keyboards substitute the ohm sign at code point U+2126, which looks the same, and plain text often falls back to the word ohm or the letter R. Write the value with a space and the symbol, such as 4.7 kΩ. Keep the number of significant figures from the source when converting: 12.0 kΩ is 12,000 Ω, and 0.0120 MΩ. State the tolerance and test conditions for a measurement, as temperature and applied voltage can alter a reading. This page defines the unit, its prefixes and its relatives, and it does not choose a component for a given circuit.
Precision and checking
- Retain source resistance precision.
- Keep resistance separate from resistivity.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Electrical resistance converter
- Ohms to Milliohms converter
- Ohms to Microohms converter
- Ohms to Kiloohms converter
- Ohms to Megaohms converter
- Ohms to Gigaohms converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.