MEASUREMENT & METHODS

Microohms (µΩ): resistance unit guide

µΩ expresses resistance in microohms.

Measurement basis

The recorded scale is 10^-6 Ω per µΩ.

Definition conventions

Prefixes use SI decimal powers, and the selections rescale known resistance values only.

Conversion method

Multiply µΩ by 10^-6 for ohms. Keep the small reference value until final formatting.

Reference equivalent of µΩ

1 µΩ = approximately 0.000001 Ω.

Recorded scale factors: 0.000001 for µΩ; 1 for Ω.

Worked example

Known input: 10 µΩ. Reference equivalent: 0.00001 Ω. The return conversion gives approximately 10 µΩ.

The example retains the original resistance despite a small decimal.

Common reference values

Input (µΩ)Reference equivalent (Ω)
10.000001
50.000005
100.00001
250.000025
500.00005
1000.0001

Compare one µΩ with other units

Target unitEquivalent of 1 µΩDefinition guide
Ohms (Ω)0.000001Read definition
Milliohms (mΩ)0.001Read definition
Kiloohms (kΩ)1e-9Read definition
Megaohms (MΩ)1e-12Read definition
Gigaohms (GΩ)1e-15Read definition
Teraohms (TΩ)1e-18Read definition

The size of a microohm

A microohm (µΩ) is 10⁻⁶ ohm. The ohm is the SI unit of electrical resistance, equal to one volt per ampere, so 1 Ω = 1 V/A. Resistances near one microohm are far below what an ordinary multimeter resolves. Typical microohm-level values include the contact resistance of a clean circuit breaker pole, which may be 20 to 100 µΩ, a bolted copper busbar joint of 5 to 50 µΩ, and a current-sense shunt of 100 µΩ. A 1 m copper bar with a 100 mm² cross section has a resistance of about 172 µΩ, from 1.72 × 10⁻⁸ Ω·m × 1 m / 10⁻⁴ m². The unit appears whenever very large currents flow through short conductors.

How the ohm is realized

The ohm is named for Georg Simon Ohm, who published his law in 1827. The name ohm was adopted at the 1881 International Electrical Congress. Since the 2019 SI revision, the ohm rests on the fixed values of the elementary charge and the Planck constant, and national laboratories realize it with the quantum Hall effect, in which the von Klitzing constant R_K = h/e², about 25,812.807 Ω, appears as a plateau of resistance in a two-dimensional electron system at low temperature. Calibration labs pass this value down through standard resistors and bridges to the instruments in the field. The micro prefix is one of the SI prefixes that the CGPM added in 1960.

Four-wire measurement and test current

A microohm reading cannot be made with two probes, because the resistance of the test leads and probe contacts is much larger than the item being measured. Digital low-resistance ohmmeters (DLRO) use the four-terminal Kelvin method: one pair of leads forces a current of often 1 A to 100 A, and a separate pair of sense leads measures the voltage across the item. At 10 A, a 50 µΩ joint produces a voltage of only 500 µV. Thermoelectric voltages at junctions of dissimilar metals can be several microvolts, so good instruments reverse the current and average the two results to cancel them. Without the four-wire method, a reading of 50 µΩ would be lost in lead resistance. If the forward reading is 52 µΩ and the reversed reading is 48 µΩ, the average of 50 µΩ removes the thermal voltage that added to one and subtracted from the other.

Power loss and voltage drop at microohm scale

A small resistance can still produce heat when the current is large. A joint of 50 µΩ carrying 100 A drops V = I × R = 5 mV and dissipates P = I² × R = 100² × 50 × 10⁻⁶ = 0.5 W. A 100 µΩ shunt at 500 A drops 50 mV and dissipates 25 W. A joint that has degraded from 20 µΩ to 60 µΩ triples its heating at the same current, which is why maintenance teams track contact resistance trends over years and flag readings that rise relative to a baseline or to comparable phases. Acceptance limits come from equipment manufacturers or standards such as the relevant circuit-breaker testing guides, and this guide does not state a pass or fail value for any device.

Battery, weld and bonding applications

The microohm range appears in several other places. Lithium-ion cell internal resistance is typically stated in milliohms, but the busbar and welded-tab connections in a battery pack may add tens to hundreds of microohms per joint. Resistance spot welds are checked by measuring the resistance across a joint, and electrical bonding in aircraft is commonly tested at 2.5 mΩ or below, which equals 2,500 µΩ. Railway rail joints, grounding grid connections and superconducting magnet splices are also checked in microohms or nanoohms. In a superconducting magnet splice, resistances near 1 nΩ (0.001 µΩ) are targeted so that heating stays low at currents of thousands of amperes. At 5,000 A, a splice of 1 nΩ dissipates 25 mW, from I² × R, while one of 1 µΩ would dissipate 25 W into a cryogenic system.

Conversions and the site converters

The site lists Ohms to Microohms, Microohms to Ohms, Kiloohms to Microohms, Microohms to Kiloohms, Milliohms to Microohms, Microohms to Milliohms, Microohms to Megaohms, Megaohms to Microohms, Microohms to Gigaohms, Gigaohms to Microohms, Microohms to Teraohms and Teraohms to Microohms. The factors are 1 Ω = 10⁶ µΩ, 1 mΩ = 1,000 µΩ and 1 kΩ = 10⁹ µΩ. A reading of 85 µΩ is 0.085 mΩ or 8.5 × 10⁻⁵ Ω, and 2.5 mΩ is 2,500 µΩ. Resistances in series add, so 40 µΩ plus 25 µΩ gives 65 µΩ, and in parallel two 100 µΩ paths give 50 µΩ. Conversions are exact scalings of the stated value.

Temperature and measurement conditions

Metallic resistance depends on temperature, so a 172 µΩ copper bar measured at 20 °C reads about 21 percent higher at 75 °C, using a coefficient near 0.0039 per kelvin. That is about 208.9 µΩ, from 172 × (1 + 0.0039 × 55). Standards for contact resistance tests often say to record the ambient temperature, test current and probe positions. A reading depends on how the test leads are placed relative to the joint, because the voltage taps define which part of the path is measured. Surface oxide, bolt torque and contact pressure also change the result. Keeping those conditions beside the number matters more than the number of decimals, and a resistance given in µΩ without them is difficult to compare with a later test.

Reading the symbol

The symbol µΩ combines the Greek letter mu and the capital omega, and plain-text versions include uohm, u-ohm and uOhm. Unicode encodes the ohm in two nearly identical characters, Greek capital omega U+03A9 and the ohm sign U+2126, which Unicode normalization treats as the same character, but older text can still use either. A value of 85 mΩ is 1,000 times larger than 85 µΩ, so a dropped or misread prefix is a major error. The microohm should not be confused with the µΩ·m used for resistivity or with the unit µS, the microsiemens, which is a conductance: 1 µΩ corresponds to a conductance of 1,000,000 S, not 1 µS.

Conductance as the reciprocal

Resistance and conductance are reciprocals, G = 1 / R. A resistance of 1 µΩ has a conductance of 10⁶ S, and 50 µΩ has 20,000 S. Because large conductances are unwieldy, microohm-level values are almost always quoted as resistance. The reciprocal view is helpful for parallel paths, where conductances add: three bolted paths of 90 µΩ each are 11,111 S apiece, giving 33,333 S, and a combined resistance of 30 µΩ. The same sum works for any parallel connection. Series and parallel rules give a first estimate, but connected conductors may not share current equally if one path has a higher resistance, so the heating of each path should be calculated separately.

Precision and checking

  • Retain measured resistance resolution.
  • Keep the micro prefix visible.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →