MEASUREMENT & METHODS

Megaohms (MΩ): resistance unit guide

MΩ is the mega-prefixed resistance unit.

Measurement basis

The stored scale is 1,000,000 Ω per MΩ.

Definition conventions

Prefixes use SI decimal powers, and the selections rescale known resistance values only.

Conversion method

Multiply MΩ by one million for ohms. Keep the source prefix case unchanged.

Reference equivalent of MΩ

1 MΩ = approximately 1000000 Ω.

Recorded scale factors: 1000000 for MΩ; 1 for Ω.

Worked example

Known input: 10 MΩ. Reference equivalent: 10000000 Ω. The return conversion gives approximately 10 MΩ.

The reference uses mega rather than milli.

Common reference values

Input (MΩ)Reference equivalent (Ω)
11000000
55000000
1010000000
2525000000
5050000000
100100000000

Compare one MΩ with other units

Target unitEquivalent of 1 MΩDefinition guide
Ohms (Ω)1000000Read definition
Milliohms (mΩ)1000000000Read definition
Microohms (µΩ)1000000000000Read definition
Kiloohms (kΩ)1000Read definition
Gigaohms (GΩ)0.001Read definition
Teraohms (TΩ)0.000001Read definition

One million ohms

A megaohm (MΩ) is 1,000,000 ohms. The ohm is the SI unit of electrical resistance, named for Georg Simon Ohm, and it is the ratio of voltage to current: 1 Ω = 1 V/A. Since the 2019 revision of the SI, the ohm follows from the fixed values of the Planck constant and the elementary charge, and the quantum Hall resistance, h/e², is about 25,812.807 Ω. The prefix mega means 10⁶. The site lists converters from megaohms to ohms, kiloohms, milliohms, microohms, gigaohms and teraohms, and the reverse directions. Metric prefix steps on resistance are exact: 1 MΩ = 1,000 kΩ = 10⁶ Ω = 0.001 GΩ = 10⁻⁶ TΩ, and the milli and micro forms scale by 10⁹ and 10¹².

Ohm's law at megaohm scale

With resistance this high, currents are tiny. A voltage of 5 V across 1 MΩ drives 5 µA, because I = V/R. A 500 V test voltage across 1 MΩ gives 0.5 mA, and 1,000 V across 100 MΩ gives 10 µA. Power is also small: 5 V across 1 MΩ dissipates 25 µW, since P = V²/R = 25/1,000,000. Resistors in series add, so 2.2 MΩ plus 3.3 MΩ equals 5.5 MΩ. Two 1 MΩ resistors in parallel give 0.5 MΩ. The reciprocal of resistance is conductance, so 1 MΩ corresponds to 1 µS. Currents measured at this scale approach the leakage of cables, circuit boards and meter inputs, which is why measurement technique matters more here than for low-value resistors.

Insulation testing

The megaohm is the working unit of insulation resistance. A megohmmeter, often called a megger after a brand name, applies a test voltage of typically 250, 500 or 1,000 V DC and reads the resistance through the insulation. Wiring regulations based on IEC 60364-6, including the UK BS 7671, set a minimum of 1 MΩ for circuits up to 500 V at a 500 V test, and good installations read far higher, often hundreds of megaohms. Motors, cables and transformers are tracked over time, because a falling reading can show moisture or contamination. Readings are temperature dependent, and insulation resistance roughly halves with every 10 °C rise, so the temperature belongs with the result. Always check the current edition of the applicable standard for the pass limit.

Electronics: inputs, probes and bias networks

Many instruments are specified by input resistance in megaohms. A typical digital multimeter presents 10 MΩ on its voltage ranges, and an oscilloscope input is usually 1 MΩ in parallel with a small capacitance, while a 10× probe raises the load to 10 MΩ. When a 10 MΩ meter measures a node fed through a 1 MΩ source resistance, it forms a divider that reads 10/11 of the true value, an error of about 9 percent. Glass pH electrodes have internal resistances of tens to hundreds of megaohms, which demands amplifiers with extremely low input current. Pull-up resistors of 1 to 10 MΩ appear where standby current must be near zero. The loading effect is the reason high-impedance sources need high-impedance meters.

Reading resistor codes at the mega range

On a color-banded resistor, 1 MΩ is brown, black, green, since 10 × 10⁵. A 4.7 MΩ part is yellow, violet, green, and 10 MΩ is brown, black, blue. Surface-mount parts use numeric codes: 105 means 10 × 10⁵ = 1 MΩ, and 475 means 47 × 10⁵ = 4.7 MΩ. The RKM notation of IEC 60062 writes the multiplier letter in place of the decimal point, so 4M7 means 4.7 MΩ and 1M0 means 1 MΩ. Tolerances such as 1 or 5 percent apply to the printed value. For a 1 MΩ resistor at 5 percent the actual value can lie from 950 kΩ to 1.05 MΩ, a range worth remembering when a measured value seems off.

Case and symbol errors

The symbol MΩ is a capital M followed by the Greek capital omega. A lowercase m means milli, so mΩ is a thousandth of an ohm, and the two differ by a factor of 10⁹. Copying a value across a case change can turn a 4.7 MΩ insulation reading into 4.7 mΩ, which describes a short circuit. Some fonts and character sets replace Ω with the similar-looking Greek letter or with the word ohm, and ASCII text often writes Mohm or MOhm. The unit k is lowercase for kilo, so kΩ has a lowercase k. When transcribing a measurement, read the prefix case from the original record before interpreting the number. If a figure appears on a scanned datasheet, check it against the nearby units for consistency.

Resistivity, leakage and surface effects

Megaohm readings often reflect surfaces and moisture as much as the bulk material. A clean, dry printed circuit board can show thousands of megaohms between traces, while flux residue or humidity may drop it to a few megaohms. Dry skin presents roughly 100 kΩ to over 1 MΩ between two electrodes, and it varies strongly with moisture and contact area, so no single value applies. Contamination across an insulator creates a leakage path in parallel with the bulk, and parallel resistances combine to a lower total. For two paths of 50 MΩ and 200 MΩ the combination is 40 MΩ, since 1/(1/50 + 1/200) = 40. High-resistance measurements also pick up noise, so guarded connections and short leads help.

Converting and checking a megaohm value

Convert through ohms when a prefix is unfamiliar. A reading of 470 kΩ is 470,000 Ω, which is 0.47 MΩ. A value of 2,200,000 Ω is 2.2 MΩ, and 0.05 MΩ equals 50 kΩ. In the other direction, 3.3 GΩ equals 3,300 MΩ, and 750,000 MΩ is 0.75 TΩ. A common check is to compare the voltage and current: if 100 V produces 20 µA, the resistance is 100/0.00002 = 5,000,000 Ω, or 5 MΩ. The site converters apply the exact decimal factors, so the quality of the result depends on the original reading. Keep the unit symbol with the number and note the test voltage for insulation readings, because insulation resistance is not constant with voltage.

Series strings and voltage dividers in the megaohm range

High-value resistors are common in voltage dividers that scale a large voltage down for a meter. A divider of 9 MΩ over 1 MΩ passes one tenth of the input to the measuring element, so 1,000 V in gives 100 V out, and the total current is 1,000 / 10,000,000 = 100 µA. The power in the 9 MΩ resistor is 90 µW at that input. Because a single resistor has a voltage rating, a divider for several kilovolts uses a string of many parts in series, each carrying a fraction of the voltage. Resistance values at this scale also drift with temperature and humidity, so precision dividers use matched, sealed parts. The meter connected across the low arm must itself be much larger than 1 MΩ or it will change the ratio.

Precision and checking

  • Retain original resistance precision.
  • Preserve uppercase M.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →