Measurement basis
Resistance and material resistivity are distinct quantities. Resistivity includes material and geometry considerations beyond a resistance-unit scale.
Definition conventions
Prefixes use SI decimal powers, and the selections rescale known resistance values only.
Conversion method
Use the resistance-factor ratio and preserve the Ω symbol and prefix case.
Choose the conversion direction
Confirm that the source is resistance, then select a target resistance unit.
What electrical resistance is
Electrical resistance is the ratio of the voltage across a component to the current through it, R = V/I, when the component behaves in a way that this ratio is meaningful. Georg Ohm published the relationship in 1827, and the SI unit, the ohm (Ω), is named for him. One ohm is one volt per ampere, which in base units is kg·m²·s⁻³·A⁻². A resistor that passes 2 A when 10 V is across it has a resistance of 5 Ω. The quantity matters for how much a wire heats, how much voltage is lost along a cable, how much current a sensor draws and how a signal divides between components. Resistance applies to a specific object with a specific shape, which separates it from resistivity, a property of the material.
How the ohm is realized in the SI
Since the 2019 redefinition of the SI, the ohm follows from fixed values of the elementary charge and the Planck constant rather than from a physical artifact. The BIPM SI Brochure notes that the von Klitzing constant, h/e², is approximately 25,812.80745 Ω, and national metrology institutes realize the ohm with the quantum Hall effect, where the Hall resistance of a two-dimensional electron system forms plateaus at fractions of this value. Calibration laboratories then pass the value down to standard resistors and to the resistance ranges of precision multimeters. For everyday work none of this matters, but it explains why high-grade resistance standards can be traced to a fundamental constant and why a calibration certificate gives an uncertainty. A bench multimeter might have a resistance accuracy of a fraction of a percent. A calibration laboratory instrument reaches parts per million or better.
Prefixes and their ranges
Resistances in practice cover many orders of magnitude, so prefixes are used constantly. Microohms (µΩ) describe busbar joints and very low-resistance contacts. Milliohms (mΩ) appear in current shunts, battery internal resistance and the on-resistance of power transistors. Ohms are the base for heating elements, speaker voice coils at 4 to 8 Ω and most wire runs. Kiloohms (kΩ) are the working range of signal circuits, with pull-up resistors, voltage dividers and potentiometers. Megaohms (MΩ) describe high-impedance inputs, insulation measurements and leakage paths, and an oscilloscope input of 1 MΩ is a standard figure. Gigaohms (GΩ) and teraohms (TΩ) appear in insulation testing and electrometer work. The prefixes are powers of 1,000, so 1 MΩ is 1,000 kΩ and 1,000,000 Ω. Because the symbol Ω is itself the unit, a conversion between prefixes moves only a decimal point.
Prefix case and plain-text pitfalls
The prefix case is the main source of error. Lowercase m means milli and uppercase M means mega, so mΩ and MΩ differ by a factor of one billion. Lowercase k is kilo, and uppercase K is not a valid SI prefix, although it appears on old parts lists and on some multimeters. In plain text the symbol Ω is often replaced by the letter R, by ohm or by the Greek capital omega, and µ may be written u. These substitutions are all understandable, but only if the case stays intact. A reading of 4.7 M that lost its Ω could be megaohms or milliohms. Electronics drawings use the RKM code from IEC 60062, where the letter replaces the decimal point, so 4k7 is 4.7 kΩ, 2R2 is 2.2 Ω and 1M5 is 1.5 MΩ. This notation survives printing and copying better than a decimal point and prefix symbol, which is why it is common on schematics.
Resistance versus resistivity
Resistance depends on size and material. Resistivity, written ρ and measured in ohm meters (Ω·m), belongs to the material alone. For a uniform conductor of length L and cross-sectional area A, the resistance is R = ρL/A. A resistivity unit contains a length factor, while a resistance unit does not, so the two cannot be converted by a prefix. Annealed copper at 20 °C has a resistivity of 1.7241 × 10⁻⁸ Ω·m, the value that underlies the International Annealed Copper Standard, and typical wire has a similar figure. For 100 m of copper wire with a cross-section of 2.5 mm², or 2.5 × 10⁻⁶ m², the resistance is 1.7241 × 10⁻⁸ × 100 / 2.5 × 10⁻⁶ = 0.68964 Ω. A round trip over two such conductors is about 1.379 Ω. At 16 A that loop drops about 22 V in total, a reminder that long runs matter. These numbers are illustrative examples of the formula.
Temperature changes resistance
Resistance values quoted without a temperature are incomplete for many materials. For metals, resistance increases with temperature. Copper has a temperature coefficient near 0.0039 per kelvin around room temperature, so a copper winding that measures 10.00 Ω at 20 °C measures about 11.57 Ω at 60 °C, found as 10 × (1 + 0.00393 × 40). Motor and transformer manufacturers use this relationship to estimate winding temperature rise from a resistance measurement. Thermistors and platinum resistance thermometers use the effect on purpose. A Pt100 sensor reads 100 Ω at 0 °C and a Pt1000 reads 1,000 Ω there, and both follow standardized curves. Negative temperature coefficient thermistors fall in resistance as they heat, and a common 10 kΩ NTC is specified at 25 °C. When recording a low resistance, note the temperature at which it was measured, since a change of a few degrees alters the third significant figure.
Measuring high and low resistances
The measurement method must match the range. A two-wire meter reading of a 1 Ω resistor includes the resistance of the leads and contacts, which may be 0.1 to 0.5 Ω, so the reading is unreliable. Four-terminal (Kelvin) sensing uses one pair of leads to carry current and another to sense voltage, removing the lead resistance from the result, and it is the standard approach for milliohm and microohm work. At the other end, an insulation resistance tester applies a test voltage, often 500 V or 1,000 V, and reports megaohms or gigaohms. A reading of 500 MΩ at 500 V corresponds to a leakage current of 1 µA. Surface contamination and humidity affect high resistances, which is why test procedures name the conditions. A low reading on an insulation test is a prompt to investigate, but acceptance limits come from the equipment standard or the installation code.
Series, parallel and power
A few relations carry the units through a circuit. Resistances in series add, so 4.7 kΩ and 10 kΩ give 14.7 kΩ. In parallel, the reciprocals add, so two 10 kΩ resistors give 5 kΩ, and a 1 kΩ resistor in parallel with a 100 Ω resistor gives about 90.9 Ω. The power dissipated is P = I²R = V²/R. A current of 5 mA through 4.7 kΩ develops 23.5 V and dissipates 0.1175 W, so a quarter-watt resistor is adequate with some derating. Because power grows with the square of current, a milliohm resistance carrying a large current can still dissipate a lot. A 2 mΩ contact resistance at 100 A dissipates 20 W. Keeping the unit prefix beside each number during these calculations helps catch errors, because kΩ and mA combine cleanly: 1 kΩ times 1 mA is 1 V.
Related units: conductance and older systems
Conductance is the reciprocal of resistance, measured in siemens (S), where 1 S = 1 Ω⁻¹. A 50 Ω resistor has a conductance of 0.02 S, or 20 mS. The earlier name for the reciprocal ohm was the mho, which was used until the siemens replaced it. Millisiemens and microsiemens appear in water quality, where conductivity is reported in µS/cm, a different quantity from resistance. In the older CGS electromagnetic system the abohm equals 10⁻⁹ Ω, and in the electrostatic system the statohm is about 8.98755 × 10¹¹ Ω. These units are mostly of historical interest, but they appear in old physics literature. Impedance and reactance are also expressed in ohms but are not equal to resistance. Reactance and impedance include the effect of capacitance and inductance at a given frequency, so an impedance of 8 Ω on a speaker is a magnitude that varies with frequency.
Conversion habits that prevent mistakes
Since all supported resistance units share the ohm and differ only in a power of ten, conversions are simple but easy to mistype. Write the prefix out the first time, then check that the result has a sensible size. A 330 mΩ shunt is 0.33 Ω. A 0.022 Ω resistor is 22 mΩ. A 4,700 Ω resistor is 4.7 kΩ. A 2.2 MΩ input is 2,200 kΩ or 2,200,000 Ω. The number should grow when you move to a smaller unit and shrink when you move to a larger one. Keep the number of significant digits from the measurement, and keep tolerance with the value: 10 kΩ ± 5 percent spans 9.5 to 10.5 kΩ. Do not convert a resistivity unit with a resistance factor. When converting between prefixes in a specification, convert the tolerance too, and keep the temperature and measurement conditions attached to the converted number.
Reading datasheets and test results
Resistance on a datasheet comes with context. A resistor lists nominal value, tolerance, temperature coefficient in ppm per kelvin, power rating and maximum voltage. A cable lists conductor resistance per kilometer at 20 °C, often in Ω/km, which is the same as mΩ/m. A battery lists internal resistance in milliohms at a stated frequency, usually 1 kHz AC, and DC internal resistance at a stated state of charge and temperature, which can differ. Insulation resistance comes with the test voltage and duration. Contact resistance for a connector is stated at a test current. In each case the number is valid only under the listed conditions. Converting the unit does not make a value from one condition comparable with another, so keep the surrounding text with the numeric value when copying it into a calculation.
What a unit change cannot tell you
Rewriting a resistance in another unit changes the written scale and nothing else. It cannot show whether the part is suitable for a circuit, whether it will survive the power applied, whether the insulation is safe at a voltage or how the value drifts with age and temperature. Those judgments depend on the circuit, the component specification and applicable electrical safety rules. Resistance values from different instruments also have different uncertainties, so two readings that look different after conversion might agree within their tolerance bands. When resistance is used to infer another quantity, such as temperature from a thermistor, moisture from a sensor or strain from a gauge, the conversion from ohms to that quantity uses the sensor's calibration curve, and the unit conversion only supplies the input number in the right scale for that curve.
Precision and checking
- Retain the source resistance precision.
- mΩ and MΩ identify different decimal scales.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Ohms (Ω)
Definition, reference values and linked conversions.
Milliohms (mΩ)
Definition, reference values and linked conversions.
Microohms (µΩ)
Definition, reference values and linked conversions.
Kiloohms (kΩ)
Definition, reference values and linked conversions.
Megaohms (MΩ)
Definition, reference values and linked conversions.
Gigaohms (GΩ)
Definition, reference values and linked conversions.
Teraohms (TΩ)
Definition, reference values and linked conversions.
Use a working converter
- Electrical resistance converter
- Ohms to Milliohms converter
- Milliohms to Ohms converter
- Ohms to Microohms converter
- Microohms to Ohms converter
- Ohms to Kiloohms converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.