Kiloohms (kΩ): resistance unit guide

kΩ uses the kilo prefix for resistance.

Measurement basis

One kΩ corresponds to 1,000 Ω.

Definition conventions

Prefixes use SI decimal powers, and the selections rescale known resistance values only.

Conversion method

Multiply kΩ by 1,000 for the resistance reference. Use the target factor for another prefix.

Reference equivalent of kΩ

1 kΩ = approximately 1000 Ω.

Recorded scale factors: 1000 for kΩ; 1 for Ω.

Worked example

Known input: 10 kΩ. Reference equivalent: 10000 Ω. The return conversion gives approximately 10 kΩ.

The worked conversion keeps the resistance quantity.

Common reference values

Input (kΩ)Reference equivalent (Ω)
11000
55000
1010000
2525000
5050000
100100000

Compare one kΩ with other units

Target unitEquivalent of 1 kΩDefinition guide
Ohms (Ω)1000Read definition
Milliohms (mΩ)1000000Read definition
Microohms (µΩ)1000000000Read definition
Megaohms (MΩ)0.001Read definition
Gigaohms (GΩ)0.000001Read definition
Teraohms (TΩ)1e-9Read definition

Definition and size

One kiloohm is 1,000 ohms, written 1 kΩ. The prefix kilo is the SI prefix for 10³, and the ohm is the SI derived unit of electrical resistance, defined as one volt per ampere. In the BIPM SI Brochure the symbol for the ohm is the capital Greek letter omega, and the prefix symbol k is lowercase. The kilohm is the working unit of signal electronics because the currents in small circuits are in the milliampere range. A voltage of 5 V across 1 kΩ drives 5 mA, a convenient size for LEDs, logic inputs and sensors. Resistors rated in tens of ohms usually mean a power or load stage, and resistors in hundreds of kiloohms mean high-impedance sensing. A part marked 10 kΩ is by far the most common value on a general-purpose electronics bench.

Conversions to ohms, megaohms and milliohms

The conversions are factors of 1,000. Multiply kΩ by 1,000 to get ohms, so 4.7 kΩ is 4,700 Ω and 47 kΩ is 47,000 Ω. Divide by 1,000 to get megaohms, so 47 kΩ is 0.047 MΩ and 2,200 kΩ is 2.2 MΩ. Multiply by 1,000,000 to get milliohms, so 0.68 kΩ, which is 680 Ω, is 680,000 mΩ. Going the other direction, 680 Ω is 0.68 kΩ and 22 Ω is 0.022 kΩ. A reading of 0.5 kΩ is 500 Ω, and a value that begins with a decimal point in kΩ often reads more naturally in ohms. A common convention is to choose the prefix that makes the number fall between about 1 and 999, so 680 Ω reads better than 0.68 kΩ and 4.7 kΩ reads better than 4,700 Ω. Both are correct, and the number carries the same information in either form.

Standard values and the E series

Fixed resistors are made in preferred values from the IEC 60063 E series, where each decade is divided logarithmically. The E12 series has twelve values per decade: 10, 12, 15, 18, 22, 27, 33, 39, 47, 56, 68 and 82, and the E24 series has twenty-four. Multiplying by 100 puts these in the kiloohm range, giving 1 kΩ, 1.2 kΩ, 1.5 kΩ, 2.2 kΩ, 4.7 kΩ, 10 kΩ and so on. The E12 series is designed for 10 percent tolerance and E24 for 5 percent, while E96 is used for 1 percent parts. The steps are chosen so that neighboring values, with their tolerance ranges, cover the whole decade with slight overlap. A circuit calculation that calls for 3.9 kΩ fits an E24 part, while one that gives 4.0 kΩ needs the nearest preferred value, such as 3.9 or 4.3 kΩ. Choosing between them depends on how sensitive the design is.

Reading values from color bands and codes

Through-hole resistors use a color code defined in IEC 60062. For a four-band part, the first two bands give digits, the third gives a multiplier and the fourth the tolerance. Brown, black, orange is 1, 0 and a multiplier of 10³, so 10 kΩ. Yellow, violet, red is 4, 7 and ×100, giving 4,700 Ω or 4.7 kΩ. Red, red, red is 2.2 kΩ. A gold fourth band means ±5 percent and silver means ±10 percent. Surface-mount parts print numbers instead. A marking of 103 means 10 followed by three zeros, which is 10,000 Ω or 10 kΩ, and 472 means 47 followed by two zeros, which is 4.7 kΩ. Four-digit codes on 1 percent parts follow the same rule with three significant digits, so 4701 is 470 followed by one zero, or 4.7 kΩ. Checking the value with a meter before soldering costs seconds and avoids mistakes.

Typical roles for kΩ values

Common roles give the kiloohm range its character. A 10 kΩ pull-up or pull-down resistor holds a logic input at a defined level while drawing only 0.33 mA from a 3.3 V supply. A 1 kΩ resistor limits LED current: for a 12 V supply and a 2 V LED drop at 10 mA, the resistance is (12 − 2) / 0.01 = 1,000 Ω. A pair of 10 kΩ resistors forms a voltage divider that halves its input. A 10 kΩ potentiometer is a standard volume or tone control. A 10 kΩ NTC thermistor, specified at 25 °C, is a widely used temperature sensor, and the Pt1000 platinum sensor reads 1,000 Ω, or 1 kΩ, at 0 °C. Audio line inputs often present an impedance in the range of 10 kΩ or more. These are common design patterns that can differ by application, so check the component data and the circuit requirements.

Worked power example

Take a 12 V supply across a single 1 kΩ resistor. The current is I = V/R = 12 / 1,000 = 0.012 A, or 12 mA. The power is P = V × I = 12 × 0.012 = 0.144 W, or 144 mW. A common quarter-watt (0.25 W) resistor can handle this in free air with margin, though designers typically derate for temperature. Now put 24 V across the same resistor. The current doubles to 24 mA, and the power rises to 24 × 0.024 = 0.576 W, more than double the rating of the quarter-watt part. Voltage squared dominates, so doubling the voltage quadruples the power. In kΩ and mA, the units are consistent without extra factors, because 1 kΩ × 1 mA = 1 V and 1 V × 1 mA = 1 mW. This coherence is the main reason the kΩ and mA pair is preferred in small-signal work.

Combining and tolerance

Series and parallel combinations of kΩ values follow the same rules as any resistance. A 2.2 kΩ and a 4.7 kΩ resistor in series total 6.9 kΩ. Two 4.7 kΩ resistors in parallel give 2.35 kΩ, and a 10 kΩ with a 10 kΩ in parallel gives 5 kΩ. Tolerance matters when the value sets a ratio. A 10 kΩ resistor with ±5 percent tolerance may lie anywhere from 9.5 to 10.5 kΩ, which is ±500 Ω. In a divider with two such resistors, the output can shift by roughly ±2.5 percent of the supply, as the extremes of the tolerance combine. Using 1 percent parts narrows the range to ±100 Ω for a 10 kΩ part. The tolerance converts with the value: ±5 percent of 10 kΩ is the same as ±0.5 kΩ. Keep both in one unit when calculating worst cases.

Loading and measurement effects

A resistance in the kiloohm range interacts with the circuit it measures or drives. A voltmeter with an input resistance of 10 MΩ connected across a 100 kΩ point loads it by 1 percent in effect, since the parallel combination is about 99 kΩ. Measure across a 1 MΩ node and the loading error becomes about 9 percent. An analog-to-digital converter input with a source resistance of 10 kΩ may settle slowly if the sampling capacitor is large, which is why datasheets state a maximum source impedance. Long wires add resistance in ohms, which is negligible against kilohms, but leakage and stray capacitance matter more. In-circuit resistance readings can be wrong because other paths in parallel pull the reading down, so a part should be isolated from the circuit before measuring. A multimeter's kΩ range is suited to such components, with autoranging meters selecting it automatically.

Writing kΩ correctly

The symbol is kΩ, with a lowercase k and the omega, with a space between number and symbol, as in 4.7 kΩ. A capital K appears on some old equipment, but K is the symbol for kelvin and is not an SI prefix. When the omega is unavailable, the written word kiloohm or kilohm is acceptable, both spellings appear in sources, and the RKM style 4k7 works on drawings. Do not write k-ohms with a hyphen. Do not confuse kΩ with kΩ/V, an older rating for the sensitivity of analog meters, where 20 kΩ/V means the meter's input resistance is 20 kΩ for each volt of full scale. Keeping the unit with the number in tables avoids such mix-ups.

What the conversion does not cover

Converting kΩ to ohms or MΩ changes the way the resistance is written. It does not tell you the real value of a part, which differs from the marking by its tolerance and shifts with temperature and age. It does not show whether a resistor can handle the power in a circuit, which depends on the power rating, mounting and ambient temperature, or the voltage across it, which has its own limit. It does not establish insulation quality, since a high resistance reading at low test voltage may not hold at operating voltage. Carbon film, metal film, wirewound and thick-film chips differ in noise, stability and inductance, so two resistors of the same kΩ value may not be interchangeable. The datasheet and the circuit requirements decide suitability.

Temperature drift in the kilohm range

Resistor datasheets give a temperature coefficient in parts per million per kelvin. A part rated at 100 ppm/K changes by 0.01 percent for each degree of temperature change. For a 10 kΩ resistor warming by 50 K from its reference temperature, the shift is 10,000 × 100 × 10⁻⁶ × 50 = 50 Ω, which is 0.5 percent and well inside a 5 percent tolerance but visible in a precision divider. Thick-film chips are often around 100 to 200 ppm/K, while metal film parts reach 25 ppm/K or better. A 10 kΩ NTC thermistor behaves very differently, falling steeply as it warms, which is why it senses temperature. The kΩ value on a thermistor label refers to 25 °C, so reading it at another temperature gives a different resistance by design.

Precision and checking

  • Keep source resistance precision.
  • Retain k with Ω.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →