Small resistances in big circuits

Milliohms matter wherever large currents flow. A starter motor cable, a current shunt, a battery terminal and a fuse all have resistances in the milliohm range, and each drops a voltage equal to the current times its resistance. At the other end, bias and sensing resistors in electronics are counted in kΩ. A spreadsheet that holds both, such as a bill of materials with a power path, benefits from a single unit. The page multiplies a kΩ value by 1,000,000 to give mΩ. The factor comes from two steps, 1,000 Ω per kΩ and 1,000 mΩ per Ω.

Shunts and battery resistance in milliohms

The default of 10 kΩ becomes 10,000,000 mΩ. A 1 kΩ resistor is 1,000,000 mΩ, and 0.1 kΩ, which is 100 Ω, is 100,000 mΩ. In reverse, a shunt of 0.5 mΩ is 0.0000005 kΩ and a battery internal resistance of 25 mΩ is 0.000025 kΩ. A good check is the digit count: each kΩ value gains six zeros. Keep a note of which direction you converted, because a result that looks reasonable in either direction can still be off by a factor of 1,000,000.

Current shunts

A shunt turns current into a small voltage. A common type is rated at 100 A and 50 mV, which makes its resistance 0.5 mΩ, since 0.05 V divided by 100 A is 0.0005 Ω. At 40 A, the drop is 20 mV and the dissipated power is 0.8 W. At the full 100 A, the shunt dissipates 5 W, and its resistance drifts as it warms, so a shunt used near its rating needs good airflow and a layout that keeps the sense wires away from the heat. A meter that reads the drop, such as a millivolt input on a battery monitor, scales the result back to amperes. Putting the shunt resistance in mΩ and the sense resistor on the amplifier input in kΩ shows how different they are: 0.5 mΩ against 10 kΩ is a ratio of 20,000,000 to 1, and the sense amplifier must draw almost no current from the shunt for the reading to hold.

Battery internal resistance

A cell or battery has an internal resistance that makes its terminal voltage fall under load. A cell with an internal resistance of 25 mΩ delivering 10 A loses 0.25 V inside itself, and it turns 2.5 W into heat. Meters specialized for this measurement report the resistance in mΩ, often by applying an AC signal at 1 kHz. Comparing cells of the same type is the main use, because an aged cell shows a higher value than a new one. A pack of four such cells in series has four times the resistance, 100 mΩ, so the same 10 A load drops 1 V inside the pack. Matching cell values before assembling a pack keeps one weak cell from carrying a disproportionate share of the heat. Chemistry, temperature and state of charge all change the number, so a reading is meaningful only when taken under comparable conditions.

Cables and connections

Cable resistance is small but not zero. A run with a total resistance of 2 mΩ carrying 150 A drops 0.3 V and dissipates 45 W as heat, which matters in a 12 V system where 0.3 V is 2.5 percent of the supply. A cold-crimped terminal might add another 0.5 mΩ at each end, which brings the 2 mΩ run to 3 mΩ and the drop at 150 A to 0.45 V. Measuring a long cable run requires a four-wire instrument, since ordinary multimeter leads have a resistance of tens of milliohms of their own. The page does not know your cable, so enter the value you measured or the value from a data sheet.

Copper traces on a circuit board

Printed circuit traces have a measurable resistance. Copper of 1 oz weight is about 35 µm thick, and with a resistivity of 1.68 times 10 to the minus eighth ohm meters at 20 °C, a square of trace has a resistance of about 0.48 mΩ. A trace 10 mm wide and 100 mm long is ten squares, so it measures about 4.8 mΩ. Carrying 5 A, it drops 24 mV and dissipates about 0.12 W. Designers of power boards check these numbers, because a long thin trace on a motor supply can cost more voltage than expected. The same trace written in kΩ is 0.0000048, which shows why mΩ is the unit for this work. The page converts the unit, and layout rules come from the board design tools.

Fuses, connectors and switch contacts

Every element in a power path adds its own milliohms: a fuse, a connector pair, a relay contact and a switch. A few milliohms in each of five elements adds up to a resistance comparable to the cable itself. Listing each part in mΩ, summing them, and multiplying by the current gives the voltage lost in the whole path. For example, 1.5, 2, 3, 1 and 2.5 mΩ sum to 10 mΩ, and 20 A through that path drops 0.2 V and dissipates 4 W, spread across the parts. Data sheets give typical and maximum values, and the maximum is the one to use for a worst-case estimate. Contact resistance rises with wear and corrosion, so the figure on a new part is a starting point. Report the sum to the precision of the least certain entry: a kΩ value of 0.0000254 has three significant digits, so 25.4 mΩ is a correct restatement and 25.400000 mΩ adds nothing. Instrument manuals list a basic accuracy for milliohm ranges, which can be 0.1 percent of the reading plus a few counts, and the last digit is often noise.

A resistor in parallel with a shunt path

Sometimes a kΩ resistor sits across a milliohm path, as with a bleeder or a sense divider. The parallel combination is almost entirely the smaller value. A 10 kΩ resistor in parallel with a 5 mΩ path gives about 4.9999975 mΩ, so it changes the result by about 0.00005 percent. Writing both in mΩ, 10,000,000 and 5, makes that effect visible. Such an estimate is also a quick way to decide that a bleeder resistor can be ignored when you calculate the voltage drop in the power path.

Right resistance, wrong cable size

The page restates a resistance in another unit and does not calculate installation limits, equipment ratings, protection, material response or compliance. A cable with the right resistance may still be too small for a load, and a shunt rated for 100 A may overheat if mounted without airflow. Check the data sheets for current ratings and temperature limits, and consult a qualified person for work on high-current systems.