Ohm meters (Ω·m): resistivity unit guide

Ω·m is the reference unit for resistivity.

Measurement basis

It retains the resistance-times-length dimension of this quantity.

Definition conventions

The reference distinguishes resistivity from resistance and keeps the material-property quantity explicit.

Conversion method

Keep Ω·m unchanged for the reference; divide by a target resistivity factor for another notation.

Reference equivalent of Ω·m

1 Ω·m = approximately 1 Ω·m.

Recorded scale factors: 1 for Ω·m; 1 for Ω·m.

Worked example

Known input: 10 Ω·m. Reference equivalent: 10 Ω·m. The return conversion gives approximately 10 Ω·m.

The example preserves the length product.

Common reference values

Input (Ω·m)Reference equivalent (Ω·m)
11
55
1010
2525
5050
100100

Compare one Ω·m with other units

Target unitEquivalent of 1 Ω·mDefinition guide
Ohm centimeters (Ω·cm)100Read definition
Microohm meters (µΩ·m)1000000Read definition
Microohm centimeters (µΩ·cm)100000000Read definition

The SI unit of resistivity

The ohm meter (Ω·m) is the coherent SI unit of electrical resistivity. It is the resistivity of a material for which a cube with sides of 1 m has a resistance of 1 Ω between opposite faces. In base units it is kg·m³·s⁻³·A⁻². Resistivity ρ links resistance to shape through R = ρL/A, where L is the length of the conductor and A its cross-sectional area. The ohm meter measures the material and not a particular sample, so a thick short bar and a thin long wire of the same copper share one value. The BIPM SI Brochure treats it as the product of the ohm and the meter.

Resistivity across materials

Metals have resistivities around 10^-8 Ω·m: silver 1.59 × 10^-8, copper 1.68 × 10^-8 and aluminum about 2.7 × 10^-8 at 20 °C. Annealed copper by the IACS standard is 1.7241 × 10^-8 Ω·m, which corresponds to a conductivity of 58 MS/m. Nichrome heating wire is about 1.1 × 10^-6 Ω·m. Seawater is about 0.2 Ω·m, drinking water about 20 to 200 Ω·m, intrinsic silicon about 2,300 Ω·m, and glass and good plastics reach 10^10 to 10^14 Ω·m and beyond. The range across materials covers more than 20 orders of magnitude, which is one reason resistivity is plotted on logarithmic scales. The values here are typical room-temperature figures, not guaranteed ones.

Wire resistance from the formula

For a copper conductor of 100 m with a cross-section of 1.5 mm², which is 1.5 × 10^-6 m², and ρ = 1.7241 × 10^-8 Ω·m, the resistance is 1.7241 × 10^-8 × 100 / 1.5 × 10^-6 = 1.149 Ω. An electrician often uses the equivalent form ρ = 0.017241 Ω·mm²/m, which gives 0.017241 × 100 / 1.5 = 1.149 Ω as well. The site Ohm meters to Ohm square millimeters per meter converter multiplies by 1,000,000 for this reason. A round trip of a 100 m cable doubles the length, so the loop resistance of the two conductors is 2.298 Ω, and the voltage drop at 10 A is 22.98 V, which is relevant to long runs at low voltage.

Copper resistivity at 70 °C versus 20 °C

Resistivity changes with temperature, and the reference temperature must be stated, usually 20 °C. Metals rise with temperature, and copper has a temperature coefficient of about 0.00393 per kelvin near room temperature. At 70 °C the resistivity is about 1.7241 × 10^-8 × (1 + 0.00393 × 50) = 2.063 × 10^-8 Ω·m, about 20 percent higher. Semiconductors and electrolytes behave the other way, with resistivity falling as temperature rises because more carriers are available. Specialized alloys such as manganin have been designed to have a nearly constant resistivity near room temperature, which is why they are used in precision shunts and standard resistors. A resistivity table without a temperature loses much of its meaning. For a heater or a motor winding, the hot resistance matters. A copper winding that measures 10.00 Ω at 20 °C reads about 11.97 Ω at 70 °C, so a motor tested cold draws more current at start than the same winding does after it has warmed, and a thermometer-free temperature estimate can be made from the resistance rise alone.

Conversions in the resistivity family

The site Resistivity converter applies exact factors: × 100 to Ω·cm, × 1,000,000 to µΩ·m, × 100,000,000 to µΩ·cm and × 1,000,000 to Ω·mm²/m. A resistivity of 1.68 × 10^-8 Ω·m is 0.0168 µΩ·m, 1.68 µΩ·cm and 0.0168 Ω·mm²/m. The reverse conversions divide by the same powers of ten. Going to Ω·cm raises the number, since 1 Ω·m equals 100 Ω·cm. A seawater value of 0.2 Ω·m is 20 Ω·cm. Because the factors are pure powers of ten, conversions are exact apart from the displayed digits.

The reciprocal view in siemens per meter

Conductivity is the reciprocal of resistivity, σ = 1/ρ, in siemens per meter. Copper at 1.7241 × 10^-8 Ω·m has σ = 1 / 1.7241 × 10^-8, about 5.8 × 10^7 S/m, or 58 MS/m, and nichrome at 1.1 × 10^-6 Ω·m has about 0.91 MS/m. Seawater at 0.2 Ω·m has 5 S/m. The IACS scale expresses a metal as a percentage of annealed copper conductivity, so a conductor of 2.87 × 10^-8 Ω·m rates 1.7241 / 2.87, about 60.1 percent IACS. Electricians work in Ω·m or Ω·mm²/m for wire, chemists and oceanographers prefer S/m or mS/cm, and the two families describe the same property in opposite directions. When a table lists both, a larger conductivity pairs with a smaller resistivity.

Field resistivity and grounding

In geophysics, resistivity surveys map the subsurface from surface electrodes, and results are in Ω·m. Dry sand and rock may exceed 1,000 Ω·m, clay and wet soils range from about 10 to 100 Ω·m, and saline groundwater is lower still. In the Wenner arrangement with equally spaced electrodes at spacing a, the apparent resistivity is ρ = 2πaR: with a = 2 m and R = 15 Ω, ρ = 188.5 Ω·m. The depth of investigation is roughly proportional to the spacing, so wider spacing samples deeper layers. Grounding system design for electrical substations uses the soil resistivity to estimate ground rod resistance, and the seasonal variation of moisture is accounted for in the design.

Resistivity is not resistance per length

A common slip confuses the ohm meter with ohm per meter. Resistance per unit length of a given wire is in Ω/m and depends on its cross-section, while resistivity is a material property in Ω·m, a product with a length. A copper wire of 1.5 mm² has about 0.0115 Ω/m, and the copper itself has 1.72 × 10^-8 Ω·m. Another confusion arises with sheet resistance, written in ohms per square, which uses resistivity divided by film thickness and so has its own unit. Resistivity also differs from resistance, measured in ohms, and from conductivity, the reciprocal, in S/m: copper is 5.8 × 10^7 S/m. Putting the quantity name with the unit avoids all three errors.

Prefixes on Ω·m values

Write Ω·m with a dot or a space and avoid Ωm if it could be mistaken for a longer symbol. Prefixes attach to the ohm, not the meter, so µΩ·m is a microohm meter, and mΩ·m a milliohm meter. Pick a scale that keeps numbers readable, such as 17.2 nΩ·m for copper, and keep the same significant figures when converting. Quote the temperature and the test method for any value used in design, and use the supplier data sheet where a material standard applies. This page defines the unit and its factors and does not judge whether a material suits an application.

Precision and checking

  • Keep source resistivity precision.
  • Retain any stated material conditions.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →