Measurement basis
Its recorded factor is 10^-8 Ω·m.
Definition conventions
The reference distinguishes resistivity from resistance and keeps the material-property quantity explicit.
Conversion method
Multiply µΩ·cm by 10^-8 to reach the reference.
Reference equivalent of µΩ·cm
1 µΩ·cm = approximately 1e-8 Ω·m.
Recorded scale factors: 0.00000001 for µΩ·cm; 1 for Ω·m.
Worked example
Known input: 10 µΩ·cm. Reference equivalent: 1e-7 Ω·m. The return conversion gives approximately 10 µΩ·cm.
The calculation includes the prefix and length factor.
Common reference values
| Input (µΩ·cm) | Reference equivalent (Ω·m) |
|---|---|
| 1 | 1e-8 |
| 5 | 5e-8 |
| 10 | 1e-7 |
| 25 | 2.5e-7 |
| 50 | 5e-7 |
| 100 | 0.000001 |
Compare one µΩ·cm with other units
| Target unit | Equivalent of 1 µΩ·cm | Definition guide |
|---|---|---|
| Ohm meters (Ω·m) | 1e-8 | Read definition |
| Ohm centimeters (Ω·cm) | 0.000001 | Read definition |
| Microohm meters (µΩ·m) | 0.01 | Read definition |
A resistivity unit with two parts
The microohm centimeter (µΩ·cm) measures electrical resistivity, the property of a material that links resistance to shape through R = ρ × L / A. One µΩ·cm is 10⁻⁶ Ω × 10⁻² m = 10⁻⁸ Ω·m, so 1 µΩ·cm equals 10 nΩ·m. Reading the unit from left to right, µ means 10⁻⁶, Ω is the ohm, and cm is the centimeter, multiplied together. This is a product unit, not a ratio, and both parts matter: a conversion that applies only the micro prefix overlooks the factor of 100 between a centimeter and a meter. The unit is convenient for metals because their resistivities fall between about 1 and 100 µΩ·cm, which gives readable numbers.
Resistivity of common metals
Handbook values at about 20 °C, in µΩ·cm, include silver 1.59, copper 1.68, gold 2.44, aluminum 2.65, tungsten 5.6, iron about 9.7 and stainless steel type 304 near 72. The standard for annealed copper, the International Annealed Copper Standard adopted in 1913, sets 100 percent IACS at 1.7241 µΩ·cm, which is 0.017241 µΩ·m or 58.0 MS/m of conductivity. Heating alloys such as nichrome fall roughly between 100 and 150 µΩ·cm depending on composition, which is why they make useful heater wire. Values from different sources vary with purity, heat treatment and temperature, so a table value is a nominal figure for a stated condition and not a guarantee for a given lot.
From resistivity to the resistance of a wire
To find the resistance of a conductor, convert resistivity to Ω·m and use R = ρ × L / A. A 10 m length of copper wire with 1 mm² cross section and ρ = 1.72 µΩ·cm equals 1.72 × 10⁻⁸ Ω·m, so R = 1.72 × 10⁻⁸ × 10 / 10⁻⁶ = 0.172 Ω. A copper busbar 1 m long with 100 mm² (10⁻⁴ m²) cross section gives 172 µΩ at the same resistivity. The calculation can also be done directly in centimeters: ρ in Ω·cm times length in cm over area in cm², with 1.72 µΩ·cm = 1.72 × 10⁻⁶ Ω·cm. Mixing centimeter resistivity with meter lengths is the usual source of errors by a factor of 100.
Copper resistivity from 20 to 100 °C in µΩ·cm
For pure metals resistivity rises with temperature, approximately linearly over modest ranges. Copper has a temperature coefficient near 0.0039 per kelvin around room temperature, so heating a copper conductor from 20 °C to 100 °C raises its resistivity from 1.68 to about 2.20 µΩ·cm, an increase of about 31 percent. The equation is ρ(T) = ρ₂₀ × (1 + α × (T − 20 °C)), and the coefficient itself varies with purity. Constantan and manganin alloys are designed to have small coefficients, which is why they appear in precision resistors and shunts. A resistivity given in µΩ·cm without a temperature is incomplete, and 20 °C or 25 °C are the most common reference points in data tables.
Thin films and sheet resistance
Semiconductor and thin-film work often quotes resistivity in µΩ·cm because film materials are measured in that unit. Sheet resistance in ohms per square equals resistivity divided by thickness: a copper film with ρ = 1.7 µΩ·cm and thickness 100 nm has Rs = 1.7 × 10⁻⁸ Ω·m / 10⁻⁷ m = 0.17 Ω per square. Thin films usually show higher resistivity than the bulk metal, since electron scattering at surfaces and grain boundaries raises it, and a 50 nm film may measure well above the bulk value. Four-point probe instruments measure sheet resistance directly, and the resistivity is then found by multiplying by the film thickness. Interconnect design on chips depends on these films.
Converting µΩ·cm to Ω·m and Ω·cm
The site lists Ohm meters to Microohm centimeters (factor 100,000,000), Microohm centimeters to Ohm meters (10⁻⁸), Ohm centimeters to Microohm centimeters (1,000,000), Microohm centimeters to Ohm centimeters (10⁻⁶), Microohm meters to Microohm centimeters (100) and Microohm centimeters to Microohm meters (0.01). So 1.72 µΩ·cm is 0.0172 µΩ·m, 1.72 × 10⁻⁸ Ω·m and 1.72 × 10⁻⁶ Ω·cm. A tungsten value of 5.6 µΩ·cm becomes 0.056 µΩ·m. A value of 110 µΩ·cm for nichrome becomes 1.10 µΩ·m. Multiply by 0.01 to go from µΩ·cm to µΩ·m, and by 100 to go back.
Resistivity and conductivity
Conductivity is the reciprocal of resistivity. A resistivity of 1.7241 µΩ·cm equals 1.7241 × 10⁻⁸ Ω·m, so the conductivity is 1/(1.7241 × 10⁻⁸) = 5.80 × 10⁷ S/m, or 58.0 MS/m, which defines 100 percent IACS. A resistivity of 2.65 µΩ·cm for aluminum gives about 37.7 MS/m, which is about 65 percent IACS. The relation lets you compare data sheets that give one or the other. Higher conductivity means lower resistivity, and metals are ranked by percent IACS in the wire and cable industry. To compare the two, take the reciprocal and keep the length unit consistent.
Plain-text spellings of µΩ·cm
The symbol µΩ·cm combines the prefix, the ohm sign and the centimeter with a middle dot. In plain text it is often written uohm-cm, uOhm-cm or µohm-cm. A source that writes only µΩ may mean resistance and not resistivity. The ohm sign Ω can be encoded as U+03A9 (Greek capital omega) or U+2126 (ohm sign), and text matching tools may treat them differently. A resistivity written as µΩ/cm with a slash would be a different quantity, resistance per length, so the symbol with a dot is the one to preserve. Read the original unit before comparing with µΩ·m tables, where the same metal has a number 100 times smaller.
Thin-film and transparent conductors
Electronics and materials papers quote film resistivities in µΩ·cm. Titanium disilicide in its low-resistivity phase measures roughly 13 to 16 µΩ·cm, which is why silicides were used to lower contact resistance on silicon gates. Indium tin oxide, the transparent conductor in displays and touch panels, has a resistivity of about 150 to 300 µΩ·cm, around a hundred times that of copper, which is why it is used as a thin transparent layer and not as a wire. A 150 nm ITO film at 200 µΩ·cm gives 2 × 10⁻⁶ Ω·m / 1.5 × 10⁻⁷ m, about 13.3 Ω per square. Doped silicon is usually quoted in mΩ·cm or Ω·cm, a scale 1,000 to 1,000,000 times higher, so unit prefixes help keep the families apart.
Matching resistivity units across data sheets
Different industries report the same property in different units. Electrical wire tables in Europe often use Ω·mm²/m, which equals 1 µΩ·m, so copper at 0.0172 Ω·mm²/m is 0.0172 µΩ·m and 1.72 µΩ·cm. North American wire tables sometimes list ohm-circular-mil per foot, where copper is about 10.37 at 20 °C. Materials physics books use Ω·m, and semiconductor sheets use Ω·cm or µΩ·cm. To compare a nichrome value of 1.10 µΩ·m from a heating-wire catalog with 110 µΩ·cm from a materials table, convert one to the other with the factor 100. Confusion between the two usually shows up as a result that is wrong by exactly 100, which is a quick clue to look for a missing meter-to-centimeter step.
Precision and checking
- Retain source resistivity precision.
- Keep µ and cm explicit.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Electrical resistivity converter
- Microohm centimeters to Ohm meters converter
- Microohm centimeters to Ohm centimeters converter
- Microohm centimeters to Microohm meters converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.