Measurement basis
The reference factor is 10^-6 Ω·m.
Definition conventions
The reference distinguishes resistivity from resistance and keeps the material-property quantity explicit.
Conversion method
Multiply µΩ·m by 10^-6 for the reference scale.
Reference equivalent of µΩ·m
1 µΩ·m = approximately 0.000001 Ω·m.
Recorded scale factors: 0.000001 for µΩ·m; 1 for Ω·m.
Worked example
Known input: 10 µΩ·m. Reference equivalent: 0.00001 Ω·m. The return conversion gives approximately 10 µΩ·m.
The example changes the resistance prefix while retaining meters.
Common reference values
| Input (µΩ·m) | Reference equivalent (Ω·m) |
|---|---|
| 1 | 0.000001 |
| 5 | 0.000005 |
| 10 | 0.00001 |
| 25 | 0.000025 |
| 50 | 0.00005 |
| 100 | 0.0001 |
Compare one µΩ·m with other units
| Target unit | Equivalent of 1 µΩ·m | Definition guide |
|---|---|---|
| Ohm meters (Ω·m) | 0.000001 | Read definition |
| Ohm centimeters (Ω·cm) | 0.0001 | Read definition |
| Microohm centimeters (µΩ·cm) | 100 | Read definition |
What a microohm meter expresses
The microohm meter (µΩ·m) is a unit of electrical resistivity, the material property in R = ρ × L / A. One µΩ·m equals 10⁻⁶ Ω·m, which is 100 µΩ·cm. The unit reads as a product of microohm and meter, so it describes a material and not a resistance: a wire of 1 µΩ·m resistivity, 1 m long and 1 m² in cross section would measure 1 µΩ, but real conductors have small cross sections and show resistances in milliohms to ohms. The microohm meter is the natural size for engineering alloys, because copper is 0.0172 µΩ·m, stainless steel type 304 is about 0.72 µΩ·m and nichrome heating alloys are near 1.1 µΩ·m, numbers that are easy to read and compare.
Metals and alloys on one scale
At about 20 °C the handbook values in µΩ·m are silver 0.0159, copper 0.0168, gold 0.0244, aluminum 0.0265, tungsten 0.056, iron about 0.097 and carbon steels from roughly 0.14 to 0.22. Resistance alloys such as nichrome sit near 1.0 to 1.5 µΩ·m, while constantan is about 0.49 µΩ·m. The International Annealed Copper Standard, set in 1913, defines 100 percent IACS as 0.017241 µΩ·m, equivalent to a conductivity of 58.0 MS/m. Purity, cold work and heat treatment change these numbers, and values from different tables can differ in the third digit. Treat any tabulated figure as a nominal value for a stated temperature, and look up the material specification when it matters. Non-metals lie far above this range: seawater is about 0.2 Ω·m, which is 200,000 µΩ·m, and intrinsic silicon is about 2,300 Ω·m, or 2.3 × 10⁹ µΩ·m. The µΩ·m unit is therefore a metals unit, and other families use Ω·m.
Heating-element example
The resistance of a conductor is R = ρ × L / A. For a nichrome wire with ρ = 1.10 µΩ·m, 2 m long and 0.5 mm in diameter, the area is π × (0.25 × 10⁻³ m)² = 1.9635 × 10⁻⁷ m², so R = 1.10 × 10⁻⁶ × 2 / 1.9635 × 10⁻⁷, which is about 11.20 Ω. On a 12 V supply that wire draws about 1.07 A and dissipates 12.9 W. The same length of copper wire with ρ = 0.0172 µΩ·m and the same diameter would measure about 0.175 Ω, around 64 times lower. Power depends on the supply as well: the same 11.2 Ω wire on 24 V draws about 2.14 A and dissipates 51.4 W, four times the heat of the 12 V case. To reach 50 W at 24 V the wire needs 11.52 Ω, which is about 2.06 m of this nichrome at 5.60 Ω per meter. The comparison shows why heating elements use high-resistivity alloys and why power cords use copper. Wire gauge tables and catalogs often publish ohms per meter, which already includes this calculation.
Ω·mm²/m is the same number
A very common engineering convention writes resistivity in Ω·mm²/m, the resistance in ohms of a conductor 1 m long with 1 mm² of cross section. Because 1 mm² is 10⁻⁶ m², the unit equals 10⁻⁶ Ω·m, which is exactly 1 µΩ·m, so the two units give the same number. Copper at 0.0172 Ω·mm²/m is therefore 0.0172 µΩ·m. Resistance of a cable then follows by dividing by the cross section in mm² and multiplying by the length in meters: 50 m of 2.5 mm² copper cable has a single-conductor resistance of 0.0172 × 50 / 2.5 = 0.344 Ω. This shortcut lets electricians use catalog values without converting areas to square meters.
Temperature coefficient and the heating wire hot state
Resistivity changes with temperature as ρ(T) = ρ₂₀ × (1 + α × (T − 20 °C)). Copper has α of about 0.0039 per kelvin, so at 75 °C its resistivity is 0.0168 × (1 + 0.0039 × 55) = 0.0204 µΩ·m, an increase of about 21 percent. Nichrome has a much smaller coefficient, on the order of 0.0001 per kelvin, so its resistance changes only a few percent between cold and operating temperature. Constantan and manganin are chosen for shunts and precision resistors because their coefficients are close to zero. A table value without a temperature is incomplete, and measured resistance in a cable that carries load current should use the operating temperature, not 20 °C.
Converting µΩ·m to Ω·m, Ω·cm and µΩ·cm
The site lists Ohm meters to Microohm meters (factor 1,000,000), Microohm meters to Ohm meters (10⁻⁶), Ohm centimeters to Microohm meters (10,000), Microohm meters to Ohm centimeters (0.0001), Microohm meters to Microohm centimeters (100) and Microohm centimeters to Microohm meters (0.01). A resistivity of 0.0172 µΩ·m equals 1.72 × 10⁻⁸ Ω·m, 1.72 µΩ·cm and 1.72 × 10⁻⁶ Ω·cm. A value of 0.72 µΩ·m for stainless steel equals 72 µΩ·cm. Because a meter contains 100 centimeters, the same material has a µΩ·cm figure 100 times its µΩ·m figure, which is a quick check when two tables disagree by that factor.
Resistivity, conductivity and percent IACS
Conductivity σ is the reciprocal of resistivity, so σ = 1 / ρ. For ρ = 0.017241 µΩ·m, σ = 1 / (1.7241 × 10⁻⁸ Ω·m), about 5.80 × 10⁷ S/m. Aluminum at 0.0265 µΩ·m has σ of about 3.77 × 10⁷ S/m, which is 65 percent of the copper standard. In the wire industry, conductivity is quoted as percent IACS, which is 0.017241 divided by the resistivity in µΩ·m times 100. Alloys sold as aluminum conductor grades commonly fall near 61 to 62 percent IACS for electrical conductor aluminum. Reporting the same property as resistivity or as conductivity changes which way the number moves with alloying: more alloy raises resistivity and lowers conductivity. Resistivity as discussed here is a direct-current property. At high frequency the current crowds toward the surface to a skin depth of √(ρ / (π × f × μ₀)), which is about 66 µm for copper at 1 MHz, so alternating-current resistance exceeds the DC value for thick conductors.
Plain-text spellings of µΩ·m
The unit combines the prefix µ, the ohm symbol Ω and the meter, separated by a middle dot. A plain-text form is uohm-m, uOhm·m or µohm-m. Writing µΩ alone loses the meter and changes the quantity from resistivity to resistance, and writing µΩ/m describes resistance per length, which depends on the cross section and is not a material property. The ohm sign can be encoded as Greek capital omega U+03A9 or the dedicated ohm sign U+2126, and the two look the same on screen. Resistivity in µΩ·m also should not be mistaken for resistivity in Ω·m, because the numbers differ by 10⁶, and soil or water resistivity tables use Ω·m, where values run from about 1 to over 1,000.
Precision and checking
- Keep measured resistivity resolution.
- Preserve source conditions.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Electrical resistivity converter
- Microohm meters to Ohm meters converter
- Microohm meters to Ohm centimeters converter
- Microohm meters to Microohm centimeters converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.