A survey in Ω·m, a corrosion table in Ω·cm

Resistivity surveys of the ground are usually written in ohm meters, while many corrosion tables for buried steel and many water quality sheets use ohm centimeters. A pipeline engineer who has a four-pin survey in Ω·m and a soil classification table in Ω·cm has to translate before the two can be compared. This page multiplies the ohm-meter value by 100 and returns ohm centimeters. It also helps students who meet both units in different chapters of the same course. The factor is easy, yet a slip of two places is common when numbers are copied between a report and a spreadsheet.

Why the number grows by 100

Resistivity is resistance times length. A length of one meter equals 100 centimeters, so the same material has a resistivity figure 100 times larger when the length is counted in centimeters. The formula is Ω·cm = Ω·m × 100. The meter and the centimeter are defined in the SI Brochure from the BIPM, and the centimeter is 0.01 m, so there is no rounding in the factor. By hand you move the decimal point two places to the right: 30 Ω·m is 3,000 Ω·cm, and 0.2 Ω·m is 20 Ω·cm. If the page returns a smaller number than the one you typed, the From and To menus are reversed.

Ten ohm meters is 1,000 ohm centimeters

The default of 10 Ω·m returns 1,000 Ω·cm. In a soil survey that is a low reading, typical of wet clay or soil with dissolved salts, and in corrosion terms it describes ground that conducts well and tends to be aggressive toward buried metal. A dry sand may read several hundred Ω·m, which would be tens of thousands of Ω·cm. The default is chosen to show the factor, so read it as an illustration. The same number can mean very different things depending on moisture and temperature at the time of the survey, and a single reading rarely describes a whole site. Surveyors usually repeat the measurement at several pin spacings, because a wider spacing samples deeper ground, and the apparent resistivity at each spacing is reported separately. Each of those numbers converts with the same factor of 100.

Reading soil classes in Ω·cm

Corrosion engineers often sort soils into classes by resistivity, with lower values meaning a more corrosive environment. The class limits are published in several guides and they differ slightly, so take them from the document that your project follows. To use such a table with a survey in Ω·m, convert each survey value first. A reading of 15 Ω·m is 1,500 Ω·cm, and 40 Ω·m is 4,000 Ω·cm. Converting before you look up the class avoids misreading a table by a factor of 100. The page performs the conversion and has no knowledge of corrosion classes, which depend on more than resistivity.

Concrete resistivity in kΩ·cm

Durability testing of concrete often reports surface or bulk resistivity in kilohm centimeters, since a higher resistivity generally means a lower rate of ion movement. A reading of 10 kΩ·cm is 10,000 Ω·cm, and the page converts the SI equivalent: 100 Ω·m is 10,000 Ω·cm. Test methods specify the probe spacing, the moisture state of the specimen and the temperature, and each of these changes the value. Do the conversion only after you have confirmed that two readings were taken under the same conditions, since a dry surface reads higher than a saturated one for the same concrete. A specimen that reads 12 kΩ·cm is 12,000 Ω·cm, which is 120 Ω·m, and a report that mixes the two scales should show both.

From Ω·cm back to Ω·m

Set Ω·cm as the source and Ω·m as the target for the opposite direction. A soil table value of 1,500 Ω·cm is 15 Ω·m, and 10,000 Ω·cm is 100 Ω·m. The page divides by 100, so the decimal point moves two places to the left. This direction is useful when a corrosion reference in Ω·cm has to feed an earthing or electrode formula that expects SI units. Because the numbers shrink, a result such as 0.2 Ω·m looks small, and writing the unit in full each time keeps it from being read as 0.2 Ω·cm, which would be a hundred times lower.

Well logs and borehole readings

Geophysical logs of boreholes record resistivity of the rock and the fluids in it, normally in ohm meters. A water-bearing formation with fresh water reads higher than one with salty water, so the log helps to identify the fluid. A report may also include fluid samples measured in Ω·cm in the lab, and the two need to be on one scale. A sample at 20 Ω·cm is 0.2 Ω·m, the value of seawater. The page makes the comparison direct. How to interpret a log depends on the tool, the borehole and the rock, and it is the job of a trained log analyst. The same two-unit habit applies to water-sample sheets from a lab, where a sample listed at 2,500 Ω·cm is 25 Ω·m.

Frequent slips

Resistivity in Ω·m is not resistance per meter, and Ω·cm is not Ω/cm. A second error is mixing resistivity with its reciprocal, conductivity, which is written in siemens per meter or microsiemens per centimeter. A conductivity of 500 µS/cm is a resistivity of 2,000 Ω·cm, which is 20 Ω·m, so take the reciprocal before you convert. A third is dropping a prefix when a lab reports kΩ·cm or MΩ·cm. Write the unit in every column, and if a result seems off by a factor of 100, check the length unit first.

Soil, concrete and well-log work each have their own method

Resistivity shows up in soil surveys, concrete durability tests and well logs, and each field has its own test method and its own guide for reading results. The converter classifies no soil, predicts no corrosion and rates no concrete, and moisture and temperature move every one of those readings. Treat the output as the same measurement in Ω·cm instead of Ω·m, with the same uncertainty as the original. Name the test method and the conditions next to the value, and keep the original unit in your notes so anyone can check the arithmetic. A spreadsheet with one column for the source value, one for its unit and one for the converted value lets a reviewer trace each number.