Water labs and earthing engineers meet here

Water treatment and laboratory work usually quote resistivity in ohm centimeters, or megohm centimeters for purified water. Earthing design and geophysical surveys work in ohm meters. When a groundwater reading in Ω·cm has to feed a soil model, or a corrosion table in Ω·cm has to be compared with a survey in Ω·m, the two need a common unit. This page divides the ohm-centimeter value by 100 and shows ohm meters. It suits technicians, students and engineers who read both kinds of report and want a fast, dependable conversion with no stray zeros.

Why dividing by 100 works

Resistivity has the dimension of resistance times length. One ohm centimeter is one ohm times a length of 0.01 m, so it equals 0.01 Ω·m. The formula is Ω·m = Ω·cm × 0.01. The SI Brochure from the BIPM defines the ohm and the meter, and the centimeter is exactly 0.01 m, so the factor has no rounding. By hand you move the decimal point two places to the left: 5,000 Ω·cm is 50 Ω·m, and 250 Ω·cm is 2.5 Ω·m. The number for a given material gets smaller in Ω·m, even though the material is unchanged. If the page returns a larger number than you typed, the From and To menus are reversed. For a quick mental check, shift two places: 4,700 Ω·cm is 47 Ω·m, and 0.35 Ω·cm is 0.0035 Ω·m.

Ten ohm centimeters is 0.1 ohm meters

The default of 10 Ω·cm returns 0.1 Ω·m. In both units this is a low resistivity for a water sample or a soil, and it fits a heavily salted solution better than fresh water. Seawater is near 20 Ω·cm, which converts to 0.2 Ω·m, so the default is a little more conductive than the sea. Soil and rock values are much higher. Keep in mind that the default is meant to show the factor, and a field reading would be more specific. Write the result with its unit, since 0.1 Ω·m and 0.1 Ω·cm differ by a factor of 100.

Purified water at 18.2 megohm centimeters

Ultrapure laboratory water approaches a resistivity of 18.2 MΩ·cm at 25 degrees Celsius, which is the value for water with only the ions that water itself produces. In Ω·cm that is 18,200,000, and the page converts it to 182,000 Ω·m. The reading is temperature dependent, so instruments compensate to 25 degrees Celsius. A reading lower than 18.2 MΩ·cm means some dissolved ions are present, for example from a worn cartridge or from carbon dioxide absorbed from the air. The converter does not judge water quality. It places the number in SI units so that it can be used in a model or a report. Drinking water falls far below this, in the low thousands of Ω·cm, which is tens of Ω·m. A reading of 3,000 Ω·cm, for instance, is 30 Ω·m.

Soil resistivity for grounding design

A grounding design starts with the soil resistivity at the site, measured with four pins in a line, the Wenner method, for example as described in IEEE Std 81. Results are normally recorded in Ω·m. A site report that lists 10,000 Ω·cm for a layer corresponds to 100 Ω·m, and a layer of 5,000 Ω·cm corresponds to 50 Ω·m. Moist clay is lower than dry sand or rock, and the value changes with the season. The page converts the number only. The design of a grounding system rests on the standard that applies to your installation and on a qualified engineer. Resistivity also varies with depth, so surveys report layers, and a single number rarely describes a site. A reading of 1,200 Ω·cm for a wet surface layer and 8,000 Ω·cm for the layer beneath convert to 12 Ω·m and 80 Ω·m. Seasonal moisture and frost change the top layer, so repeat the survey when the design depends on worst-case conditions.

From ohm meters back to ohm centimeters

Choose Ω·m as the source and Ω·cm as the target to read an SI figure in the unit used by a water lab or a corrosion table. A soil value of 100 Ω·m is 10,000 Ω·cm, and 2.5 Ω·m is 250 Ω·cm. The page multiplies by 100, so the decimal point moves two places to the right. This is the direction needed when a geophysical survey in Ω·m has to be set against a table of corrosion classes that lists Ω·cm. Match the units first and compare afterwards, because corrosion tables and survey reports are written by different groups.

Conductivity is the reciprocal

Many instruments report conductivity, not resistivity. Conductivity in siemens per meter is one divided by the resistivity in ohm meters, so 100 Ω·m is 0.01 S/m. Water meters often use microsiemens per centimeter, and a reading of 500 µS/cm corresponds to a resistivity of 2,000 Ω·cm, which is 20 Ω·m. This page handles the resistivity side only. If your instrument reports conductivity, take the reciprocal first, then convert the unit with the page. The reciprocal relation is exact, and the temperature at which a reading was taken matters more than the arithmetic.

Common mix-ups

The unit Ω·cm is not Ω/cm, and Ω·m is not Ω/m. Resistivity is a property of a material, and resistance per length is a property of a particular wire. A second slip is mixing up resistivity and conductivity, which are reciprocals. A third is dropping the prefix, so that MΩ·cm is read as Ω·cm. A reading of 18.2 MΩ·cm is 18,200,000 Ω·cm, and the conversion to Ω·m must start from that number. When a result looks off by a factor of 100, the length unit is the likely cause. Writing the unit in every column avoids most of these mistakes. If a lab instrument displays kΩ·cm, multiply by 1,000 first.

A water sample reading gives no corrosion verdict

A converted figure tells you how strongly a material resists current, now written per meter instead of per centimeter. It does not rate water quality, predict corrosion, derive the resistance of a ground rod or choose a conductor size, since each of those needs geometry, temperature, chemistry and the standard for the case. The figure keeps the uncertainty of the original reading. Write the temperature and the method beside every value, and keep the first unit in your notes so that a later reader can check the arithmetic by dividing by 100. A column for the source value and a column for the converted one is enough for that.