From soil surveys to conductor tables
Geophysical surveys, earthing studies and water reports give resistivity in ohm meters. Conductor data sheets, resistance alloys and precision resistor specifications give it in microohm meters. A student or engineer who wants to see how far apart these worlds are, or who needs one unit in a spreadsheet, can use this page. It multiplies Ω·m by 1,000,000 and shows µΩ·m. Because only the micro prefix changes, the conversion is the simplest in the resistivity family, and it is a good starting point for learning how the other pairs work.
One prefix, one factor
The meter stays in the unit, so the only change is the micro prefix on the ohm. Micro is 10^-6 in NIST SP 811 and the BIPM SI Brochure, so one ohm is 1,000,000 microohms, and µΩ·m = Ω·m × 1,000,000. The factor has no rounding. By hand, the decimal point moves six places to the right: 0.2 Ω·m becomes 200,000 µΩ·m, and 0.0000000168 Ω·m becomes 0.0168 µΩ·m. A smaller output than input means the menus are the wrong way round, because every Ω·m value becomes a figure a million times larger in µΩ·m. The pair of Ω·m and µΩ·cm differs by an additional factor of 100, which is covered by a separate page. Because the length unit does not change, you can check any result by shifting the decimal point six places and counting zeros, and no hidden length factor is involved, unlike conversions that involve centimeters or square millimeters.
Ten ohm meters is ten million microohm meters
The default of 10 Ω·m returns 10,000,000 µΩ·m, or 1 × 10^7 µΩ·m. A resistivity of 10 Ω·m is typical of wet soil, clay or brackish water, and it is a very poor conductor by metal standards. In µΩ·m the figure is large because the unit is chosen for metals, where values between 0.01 and 2 are usual. The default checks the factor and illustrates the contrast between environmental materials and conductors. When you write up a soil value, Ω·m is the sensible unit, and µΩ·m is useful only when you want a direct comparison with metals.
Seawater next to copper
Seawater has a resistivity of roughly 0.2 Ω·m, which the page converts to 200,000 µΩ·m. Copper is near 0.0168 µΩ·m. The ratio is about twelve million, which is why salt water, though it conducts current, is a poor conductor next to a wire. Putting both in the same unit makes the comparison visible at a glance. The sea value depends on temperature and salinity, and the page uses the number you enter. For a design that involves electrodes in water, use the measured resistivity of the actual water and follow the standard for your application. For a freshwater lake, a value of 20 Ω·m would be 20,000,000 µΩ·m, and the gap to copper grows to more than a billion.
Soil values and a conductor in one table
A grounding report may list soil layers at 50 Ω·m and 120 Ω·m. In µΩ·m these are 50,000,000 and 120,000,000. A copper ground conductor at 0.0168 µΩ·m is billions of times more conductive than the soil around it, which is why the soil dominates the resistance of an earthing system. The conversion makes that gap concrete and explains why design focuses on the soil and the electrode geometry, not on the conductor material. The page does not design an earthing system. It shows the numbers in a common unit, and the design belongs to a qualified engineer. Rock is higher still, with dry crystalline rock often reading in the thousands of Ω·m or more, though moisture and fractures change the value.
From microohm meters to ohm meters
Choose µΩ·m as the source and Ω·m as the target to reverse the step. A resistance alloy at 1.1 µΩ·m is 0.0000011 Ω·m, and 0.0168 µΩ·m is 0.0000000168 Ω·m. Returning to ohm meters takes a division by one million, which is a shift of six decimal places leftward. These values are tiny, and scientific notation is the clearer form: 1.1 × 10^-6 Ω·m. Simulation tools in SI units expect this form, and some accept the e notation, so 1.1e-6 is a valid entry. Check the field label before pasting any value.
Choosing the unit that fits the material
A good unit keeps the number between about 0.1 and 1,000. For soils, water and rocks, Ω·m does that. For metals and alloys, µΩ·m does that. For semiconductors, Ω·cm is the usual choice. When a document spans several materials, either use one unit with scientific notation or give a table with the unit per column. This page lets you test both choices quickly. A column that lists 0.0168 for copper and 50,000,000 for soil in the same unit is accurate but hard to read, so a logarithmic chart may suit the comparison better. A sensible compromise for a mixed document is Ω·m throughout, with scientific notation for metals, such as 1.68 × 10^-8 Ω·m for copper, and a note giving the µΩ·m equivalent of 0.0168.
Common errors with the micro prefix
The Greek letter mu is easy to lose. In plain text it becomes u, and in uppercase it may turn into an M, which means mega and changes the value by a factor of 10^12. A table that shows MΩ·m for a metal is almost always a lost micro sign. Another slip is to treat µΩ·m as milliohms, which would be a factor of 1,000 off. Check each value against a known metal: copper at 0.0168 µΩ·m is a good anchor, and a result that is thousands of times away from it needs a second look. Spreadsheets that auto-format a long number may show it as 1E+07, which is fine, or truncate it, which is not. Widen the column and check the displayed digits against the page.
Soil moisture and salt move the number before any conversion
Soil and water resistivity swing with moisture, temperature and salt content, and metals shift with temperature and processing. The page measures none of this. It does not find the resistance of an electrode, correct for temperature or judge a material for a job. Use measured data and the standard for your application, and let the converted figure carry the uncertainty of the original. A survey might list 100 Ω·m for one layer and 20 Ω·m for another. Written in µΩ·m those are 1 × 10^8 and 2 × 10^7, which changes how the values are written and leaves the ground exactly as it was. Report the temperature, the soil or water condition and the method next to any number you convert.