Handbook values in Ω·m, wire sums in Ω·mm²/m

Reference tables and physics texts list the resistivity of copper and aluminum in ohm meters, a very small number with a power of ten. A wire calculation, on the other hand, is easiest when length is in meters and the cross-section is in square millimeters, because that is how conductors are sized and sold. In that setting resistivity in ohm square millimeters per meter gives the resistance in ohms directly. This page multiplies Ω·m by 1,000,000 to produce the wire-table form. It suits electricians, students and makers who start from an SI table and want a figure they can put straight into the wire formula.

Square millimeters explain the million

A square millimeter is a square with sides of 0.001 m, so it covers 10^-6 m². A resistivity of one ohm meter spreads over a cross-section of one square meter. Counting the cross-section in square millimeters makes the area unit a million times smaller, so the number grows by a million: Ω·mm²/m = Ω·m × 1,000,000. The prefix and the meter come from the SI Brochure of the BIPM and NIST SP 811, and the factor has no rounding. By hand you move the decimal point six places to the right. If the page returns a smaller number, the From and To menus are reversed.

Ten ohm meters is ten million Ω·mm²/m

The default of 10 Ω·m returns 10,000,000 Ω·mm²/m. A resistivity that large belongs to a poor conductor such as damp soil, and a wire table would never list it for a metal. For metals the numbers in Ω·mm²/m fall between about 0.01 and 1.5, so a result in the millions signals that the input was in the wrong range. The default simply shows the factor at work. A sensible test of any conversion is to apply it to a known metal: copper at 1.68 × 10^-8 Ω·m should give a figure near 0.0168 in the wire-table unit, which the page confirms. Doing this check first costs a few seconds and tells you whether your table is in Ω·m at all, since some tables list the same figure as 1.68 µΩ·cm or 16.8 nΩ·m.

Copper wire resistance from an SI value

Take copper at 0.0000000168 Ω·m, which the page converts to 0.0168 Ω·mm²/m. For 100 m of wire with a cross-section of 1.5 mm², the resistance is 0.0168 × 100 / 1.5 = 1.12 Ω. That is the resistance of the conductor alone for one direction of the run, and a circuit that goes out and back doubles it. Real cables may use stranded conductors and a slightly higher practical value, often 0.0175, and the resistance rises with temperature. The arithmetic of length and area is carried out outside the page, which converts only the resistivity. A second case: 25 m of the same copper at 4 mm² gives 0.0168 × 25 / 4 = 0.105 Ω, and a 10 m run of aluminum at 6 mm² gives 0.0265 × 10 / 6 = 0.0442 Ω, rounded to three significant digits.

Aluminum and resistance alloys

Aluminum at 0.0000000265 Ω·m converts to 0.0265 Ω·mm²/m, and constantan at about 4.9 × 10^-7 Ω·m converts to 0.49. Nichrome, at roughly 1.1 × 10^-6 Ω·m, gives 1.1. The progression from 0.0168 to 1.1 shows the range available to someone choosing a wire: copper for low loss, alloys for heating elements and shunts. These values are typical handbook levels, and each grade and temperature has its own figure, so take the number for your wire from the supplier. The converter moves a value between SI and wire-table units without changing it. Resistance alloy sheets usually quote the value at 20 degrees Celsius with a separate temperature coefficient, which you apply yourself.

Going back to ohm meters

Choose Ω·mm²/m as the source and Ω·m as the target to restate a wire-table value in SI. A value of 0.0175 Ω·mm²/m is 0.0000000175 Ω·m, which is 1.75 × 10^-8 Ω·m, and 1 Ω·mm²/m is 0.000001 Ω·m. Coming back from a wire table needs a division by one million, so the point travels six places to the left. Results this small are clearer in scientific notation, and many simulation programs accept the e form, such as 1.75e-8. Check how your software reads the number before running a model, because a misplaced exponent changes a wire model by orders of magnitude.

Reading the compound unit

The label Ω·mm²/m looks like a ratio of things that are different from resistivity, yet it is a legitimate unit of the same quantity. It states the resistance of a conductor one meter long with a cross-section of one square millimeter. That makes the number intuitive for wire: 0.0168 means that a meter of 1 mm² copper has a resistance of 0.0168 Ω. In base SI units the same quantity is in ohm meters, and the two differ by the factor on this page. Treat the entire expression as a single unit and do not multiply the input by a number of square millimeters.

Mistakes to avoid

A common slip is to treat Ω·mm²/m as Ω/m. The first describes a material, the second describes a given wire. Another is to apply the factor of 1,000 for millimeters instead of 1,000,000, because the area is squared. A third is to mix up µΩ·m and Ω·mm²/m, which share the same numerical value and are easy to confuse but are different spellings of the same unit size. If a result for a metal is not between 0.01 and about 1.5, review the units. A check against copper takes seconds and prevents most errors in a wire table. Also watch for a table that lists the value as 1.68 × 10^-8 and leaves out the unit, since the missing label is where most mix-ups begin. In that case the exponent tells you the table is in Ω·m, and this page gives the matching wire-table figure of 0.0168.

Handbook Ω·m values and wire-table values on one scale

A handbook gives copper in Ω·m and a wire table gives it in Ω·mm²/m, so a calculation that mixes the two goes wrong by a factor of a million. The page removes that mismatch and stops there. Voltage drop, cable size, temperature correction and wiring-rule checks all need the current, the run length, the installation method and the rules where you live, and a qualified electrician or engineer should handle them.