Putting wire-table data into an SI model
Conductor tables give copper at 0.0175 Ω·mm²/m, and that is how an electrician or a cable catalog thinks. A finite-element program, a circuit simulator or a physics report expects ohm meters, so a conversion has to happen at the boundary. This page divides by 1,000,000 and returns Ω·m. It serves students who build a model of a coil or a busbar, engineers who document a design in SI, and anyone who takes a catalog figure and needs the form that a formula in base units requires.
A million from square millimeters
A square millimeter equals 10^-6 m², so a resistivity of 1 Ω·mm²/m equals 10^-6 Ω·m. The formula is Ω·m = Ω·mm²/m × 0.000001. NIST SP 811 and the BIPM SI Brochure give the meter and the prefixes, and the factor has no rounding. By hand you move the decimal point six places to the left: 0.0175 becomes 0.0000000175, which is 1.75 × 10^-8. Because the results are small, scientific notation is the clearest way to record them. If the page returns a larger number than the one you typed, the From and To menus are reversed.
Ten Ω·mm²/m as 0.00001 Ω·m
The default of 10 Ω·mm²/m returns 0.00001 Ω·m, which is 1 × 10^-5 Ω·m. The engine prints 0.000009999999999999999 because of floating-point arithmetic, and the trailing nines are noise. The value is high for a metal, since resistance wire is near 1 Ω·mm²/m, so the default is a test of the factor. If you are working with copper, a result near 1.7 × 10^-8 Ω·m is what you should see. A result that is far from that tells you to check the units of the input.
The annealed copper standard
The International Annealed Copper Standard fixes a resistivity of 0.017241 Ω·mm²/m at 20 degrees Celsius for 100 percent conductivity. On the page this is 0.000000017241 Ω·m, or 1.7241 × 10^-8 Ω·m, and the matching conductivity is about 58 MS/m. Material grades are then described as a percentage of that standard. Hard-drawn copper is a little below 100 percent, and electrical-grade aluminum is near 61 percent. A value that you convert with the page can be compared with 1.7241 × 10^-8 Ω·m to see where a conductor sits relative to the standard. For example, a conductor measured at 0.0175 Ω·mm²/m has a resistivity of 1.75 × 10^-8 Ω·m, which is about 98.5 percent of the standard conductivity (0.017241 divided by 0.0175), a plausible figure for hard-drawn copper at room temperature.
Aluminum and heating alloys in SI
Aluminum at 0.0265 Ω·mm²/m is 0.0000000265 Ω·m, and a nichrome wire at 1.1 Ω·mm²/m is 0.0000011 Ω·m. Written in scientific notation these are 2.65 × 10^-8 and 1.1 × 10^-6 Ω·m, which is how many textbooks list them. The two differ by a factor of more than forty, and that gap decides which one you use for a power cable and which for a heater. As always, grades and temperatures change the figures, so use the data of your supplier for design, and use the converter only to restate numbers. The conductivity of the nichrome value is about 0.9 MS/m, next to 58 MS/m for annealed copper, which shows the gap in familiar terms.
Back from Ω·m to Ω·mm²/m
Choose Ω·m as the source and Ω·mm²/m as the target to read an SI value in the unit that wire tables use. A resistivity of 0.0000011 Ω·m is 1.1 Ω·mm²/m, and 1.68 × 10^-8 Ω·m is 0.0168. To go the other way, multiply by one million and move the point six places to the right. This is the direction needed when a simulation gives an effective resistivity in SI units and you want to compare it with a wire catalog. Type the small number in plain decimal form, because some fields do not accept exponent notation. Type the small number in plain decimal form, because some fields do not accept exponent notation, and some spreadsheet cells will turn 0.0000000175 into 0 if they are formatted with two decimals.
Conductivity as the reciprocal
Material data may give conductivity in siemens per meter or in megasiemens per meter, which is the reciprocal of resistivity in Ω·m. Copper at 1.7241 × 10^-8 Ω·m has a conductivity of 58 MS/m. Because the reciprocal is exact, you can convert a wire-table resistivity to Ω·m with this page and then invert it for conductivity. Some tables give conductivity in m/(Ω·mm²), which is the reciprocal of Ω·mm²/m, with copper near 58. Use the unit your formula expects and write it next to the value, since the numbers are easy to confuse. A table of 58 for copper and a table of 0.0172 for the same copper are saying the same thing in reciprocal forms.
Typical mistakes
The usual slips are applying a factor of 1,000 instead of 1,000,000, forgetting that the area is squared, and mixing resistivity with conductivity. Another is to drop an exponent when copying a number such as 1.75e-8 into a spreadsheet that formats it as zero. A fourth is to read Ω·mm²/m as a resistance per meter. A sanity check against copper, which should be near 1.7 × 10^-8 Ω·m, catches most of them. If the converted result for a metal is not near 10^-8 or 10^-7 Ω·m, look at the source unit again.
A hot copper conductor needs its own resistivity
The page restates a resistivity in other units. It does not calculate resistance, voltage drop, power loss or the size of a conductor, and it does not correct for temperature or frequency. The skin effect, for instance, makes an alternating current use less of the cross-section at high frequency, and no unit conversion accounts for that. For a design, use the full model and a reliable data source, and let a qualified engineer review it where safety is involved. Round the converted figure to the digits supported by the source, and note the temperature at which the source value applies. Resistivity of copper rises by roughly 0.4 percent per degree Celsius near room temperature, so a conductor at 60 degrees Celsius has a noticeably higher value than the 20 degree figure, and the unit conversion does not change that. When a model asks for the resistivity at operating temperature, apply the temperature correction to the Ω·m value you obtained here, not to the wire-table figure you started with, and state which one you corrected in your notes.