Shunts and pull-ups in one parts list

A bill of materials for a power board mixes parts that differ enormously in resistance. A current-sense shunt may be 5 mΩ, a gate resistor 10 Ω, a pull-up resistor 4.7 kΩ and a bias resistor 100 kΩ. When the list is sorted or plotted, the unit labels matter, since the numbers have no common scale. This page converts a milliohm value to kiloohms so that you can enter everything in one unit, for example in a spreadsheet used to generate a purchasing report or a simulation netlist. It is also helpful for checking a ratio, such as how much smaller the shunt is than the resistors that sense or bias around it.

The millionfold step

A milliohm is one thousandth of an ohm and a kiloohm is one thousand ohms, so one kiloohm contains one million milliohms. The factor 10^-6 is exact, because the prefixes are defined in the BIPM SI Brochure and tabulated in NIST SP 811. A hand check is to divide by 1,000 to reach ohms and by 1,000 again to reach kiloohms. Entering 10 mΩ gives 0.00001 kΩ, and entering 250 mΩ gives 0.00025 kΩ. The decimal point moves six places to the left. A 10 mΩ shunt beside a 10 kΩ pull-up is a ratio of one million, so the pair spans the whole range of a typical parts list. If your result has fewer than five zeros after the point for a small milliohm figure, a digit was lost somewhere in the entry.

A shunt against a pull-up

Take a 5 mΩ shunt and a 4.7 kΩ pull-up resistor. In kiloohms the shunt is 0.000005 kΩ, and the pull-up is 4.7 kΩ. Their ratio is 4.7 divided by 0.000005, which is 940,000, so the pull-up is almost a million times larger. In a divider, the shunt would drop under 0.0001 percent of the voltage across the pair. The ratio also explains why a shunt can be placed in a high-current path without disturbing the signal circuits around it. The converter makes the comparison direct. Entering 0.5 mΩ gives 0.0000005 kΩ, and 100 mΩ gives 0.0001 kΩ, which is a typical value for a small fuse or a low-value sense resistor.

Reading values off a sense resistor

Current-sense resistors are sold in values from below 1 mΩ to several hundred milliohms, and the package marking may show the value as R005 for 5 mΩ or 5L00 on some series. A designer chooses the value by the voltage that the amplifier needs at full current. At 20 A, a 5 mΩ resistor drops 0.1 V and dissipates 20² × 0.005 = 2 W, which tells you whether the package can carry the heat. The page does not do this arithmetic, but converting the value to kiloohms is the step you need when your schematic tool lists every part in kΩ. Cross-check by multiplying the result by one million.

Converting kiloohms to milliohms

Select kiloohms as the source and milliohms as the target to multiply by one million. A resistor of 4.7 kΩ becomes 4,700,000 mΩ, and 0.0022 kΩ, which is 2.2 Ω, becomes 2,200 mΩ. This direction is the natural one when a component database stores values in milliohms and a schematic provides kiloohms. Because the outputs run to seven digits, group them by thousands when copying. If the number looks small where you expected a large one, check that the selections are not reversed, since the same pair of units gives answers that differ by a factor of 10^12 between the two directions. Likewise 0.47 kΩ is 470,000 mΩ and 100 kΩ is 100,000,000 mΩ, values that show how far apart a pull-down and a shunt sit.

Four-wire measurement and the leads

A milliohm value measured with an ordinary two-wire multimeter is unreliable, because the probe leads and contact resistance can add 0.1 to 1 Ω, which is far more than the part itself. A four-wire, or Kelvin, measurement sends current through one pair of leads and senses voltage with another, which removes most of that error. Specifying a part at 5 mΩ in kiloohms is a bookkeeping step, and it does not make the measurement easier. When you compare a measured value with a datasheet limit, confirm that both used the same method and temperature, since the resistance of copper alloys rises by roughly 0.4 percent per degree Celsius.

E-series values and where shunts fit

Standard resistors are made in preferred values, such as the E12 series with 1.0, 1.2, 1.5, 1.8, 2.2, 2.7, 3.3, 3.9, 4.7, 5.6, 6.8 and 8.2 in each decade. A 4.7 kΩ part belongs to that series, while a 5 mΩ shunt is a special low-value part with its own value list. Seen in kiloohms, 4.7 and 0.000005 show that the shunt sits more than six decades below the lowest value in a typical resistor drawer. That gap is why shunts come from a separate catalog and why their tolerance is quoted in percent of a very small value, often 1 percent. Drawings should use the unit that keeps the number readable: a shunt marked 0.000005 kΩ is confusing, while 5 mΩ is clear. Reserve kiloohms for values from about 1 kΩ upward. Use the converter when a netlist generator or unit-checking script wants a single unit, then return to 5 mΩ and 4.7 kΩ for the printed documents.

Parts-list spreadsheets mixing mΩ and kΩ

Mixed units in one column cause most bad conversions. Give each resistance its own unit column, convert with the page or a formula into a single unit and check a few rows by hand. A formula that divides by 1,000,000 should be tested on a known value, such as 1,000,000 mΩ equal to 1 kΩ. Avoid unit prefixes inside number cells, since a cell that reads 4k7 or 5m cannot be summed. If you import values from a supplier file, look for mΩ and MΩ spelled with the wrong case, a problem that shifts results by 10^9 and is easy to miss on a long list. The page converts a resistance from one unit to another. It does not add resistances, calculate a divider, estimate power or check a tolerance. The conversion carries no uncertainty beyond the number you enter, so any error in the result comes from the measurement or the datasheet you started from.