Why microohms exist
Some of the most important resistances in electrical equipment are tiny. The contact between two busbars, the closed contacts of a circuit breaker, a welded joint on a battery terminal and a current shunt are all measured in microohms or milliohms. This page converts a resistance in ohms into microohms by multiplying by one million. The default of 10 Ω becomes 10,000,000 µΩ. The page works in both directions, so a microohm reading from a test instrument can be written in ohms for a calculation. The conversion is exact because the prefix micro is exactly 10⁻⁶.
The ohm and its definition
The ohm is the SI unit of electrical resistance, equal to one volt per ampere. Since the 2019 redefinition of the SI, it is tied to fixed values of the elementary charge and the Planck constant. The quantum Hall effect gives a resistance of h divided by e squared, the von Klitzing constant, which is about 25,812.807 ohms, and national laboratories use quantum Hall devices as resistance standards. The unit is named for Georg Simon Ohm, who published his law relating voltage, current and resistance in 1827. The micro prefix is one millionth. A microohm is therefore a resistance so small that a current of one ampere across it develops a voltage drop of one microvolt. That relation explains why measuring it requires large currents and careful wiring. The converter works with the unit names and ignores the physics behind them.
Reading the default and a second example
The default result, 10,000,000 µΩ, may look large, but ten ohms is a modest resistance, the kind of value found in a small resistor or a low-power heating element. A contact resistance is the sort of value more suited to the unit. Suppose a breaker contact measures 0.00025 Ω on a meter that reports in ohms. Multiplying by one million gives 250 µΩ. Suppose a shunt is rated at 2.5 mΩ. In microohms that is 2,500 µΩ. And 1 meter of 10 mm² copper conductor at 20 °C has a resistance of about 1.724 mΩ, which is 1,724 µΩ, using the standard resistivity of annealed copper. These numbers are illustrations and do not stand for any particular device. The conversion shows the same resistance in different clothes, and the choice of unit depends on which gives the cleaner number.
Four-wire measurement and micro-ohmmeters
Measuring a microohm resistance with an ordinary two-wire multimeter does not work, because the test leads and their contacts have resistance of the same size or larger. Micro-ohmmeters use a four-wire method, also called Kelvin sensing. Two leads carry a known test current, often from 10 A upward, and two separate leads sense the voltage across the item. Dividing the voltage by the current gives the resistance. Because the sense leads carry almost no current, their resistance does not enter the result. The readouts are commonly in microohms or milliohms. This is a measurement technique and the converter has no part in it. It simply expresses the instrument result in the unit that a procedure, a record or a specification uses, such as microohms for a joint or ohms for a calculation.
Power and voltage drop at low resistance
Even a small resistance produces heat when it carries a large current. The power dissipated is the square of the current times the resistance. A joint of 250 µΩ carrying 100 A drops 25 mV and dissipates 2.5 W. The same joint carrying 1,000 A drops 250 mV and dissipates 250 W, a hundred times more for ten times the current. That square relation is why joint resistance matters in high-current equipment and why maintenance programs track it over time. The numbers here are physics illustrations for a made-up joint. They do not say whether a given resistance is acceptable, and no unit converter can. Acceptance criteria come from the equipment manufacturer, the applicable standard and the conditions of use. This page gives the figure in microohms. Interpretation belongs to qualified personnel.
Shunts and battery resistance
Two other places meet microohms and milliohms every day. A current shunt turns current into a small voltage. A common 100 A shunt with a 75 mV output has a resistance of 0.75 mΩ, which is 750 µΩ. The resistance is kept small so that the shunt wastes little power: at 100 A it dissipates 7.5 W. Batteries have an internal resistance that drops the terminal voltage under load. A single cylindrical lithium cell might be tens of milliohms, which is tens of thousands of microohms, while a large starter battery can be a few milliohms. At 100 A, a 5 mΩ internal resistance means a 0.5 V sag. The figures here are illustrative magnitudes and not specifications of any product. The converter expresses a resistance in either unit, and the data sheet or the test report remains the source of the actual value.
Metals, wires and resistance per meter
The resistance of a wire is its resistivity times its length divided by its cross-sectional area. Annealed copper at 20 °C has a resistivity of about 1.724 × 10⁻⁸ ohm-meters, which is the basis of the 100 percent IACS conductivity standard. For a conductor with a 1 mm² area, one meter has a resistance of 17.24 mΩ, or 17,240 µΩ. A 10 mm² conductor has a tenth of that per meter, 1,724 µΩ. Aluminum, with a resistivity near 2.65 × 10⁻⁸ ohm-meters, has about 1.5 times as much resistance for the same size. Temperature raises resistance, by around 0.39 percent per kelvin for copper near room temperature. The converter changes units only, and it applies no temperature correction or size lookup. Use the formula for the wire calculation, then use the page to present the result in microohms.
Greek letters and encoding traps
Two symbols in this unit are easy to mistype and cause subtle problems in spreadsheets and databases. The ohm sign has its own Unicode character, U+2126, and the Greek capital omega, U+03A9, is a different character that looks the same. Standards recommend the Greek omega as the normal choice. The micro sign, U+00B5, and the Greek small letter mu, U+03BC, are also distinct characters that look identical. Search or sort operations can treat them as different, so a column of data with mixed characters may fail to match. Plain-text exports sometimes replace the symbols with a lowercase u or the word ohm. Writing uOhm is common and understood. For data entry, pick one convention and keep it throughout a file. The converter itself handles numbers and does not depend on which glyph appears in your records.
Common mistakes
Several errors repeat. One is dividing by a million when you should multiply. A microohm is a smaller unit than an ohm, so the number in microohms must be larger. Another is mixing m and µ, which changes the answer by a factor of a thousand. A 2.5 mΩ shunt is 2,500 µΩ, not 2.5 µΩ. A third is reading a four-wire instrument result as if it included lead resistance. A fourth is carrying a measurement taken at one temperature into a record without noting the temperature, since copper changes by about 0.4 percent per kelvin. Last, resistance and resistivity are different. Resistivity is a property of a material, in ohm-meters, while resistance depends on shape. The converter changes one unit of resistance into another. A separate converter handles resistivity.
Rounding and recording
The factor is exact, so the only question is how many digits to keep. Micro-ohmmeters commonly resolve 0.1 µΩ, with accuracy of perhaps 0.2 to 1 percent of reading, so a result of 250.0 µΩ is about as detailed as the measurement allows. In a record, store the instrument value and unit exactly as displayed, plus the test current and the temperature if known. Convert to other units only for calculations. When values are tracked over time, use the same unit throughout and compare to the same test current. A drift from 250 to 260 µΩ is 4 percent and may be worth noting, and the decision on what to do belongs to the maintenance program. The converter gives accurate figures. It does not interpret trends or set limits.
What this page does not do
Whether 250 µΩ is acceptable for a breaker contact or a busbar joint is outside what a unit conversion can say. Acceptance limits come from the equipment manufacturer, the applicable standard and the conditions of use, and electrical work should be done by qualified people. The ohm to microohm relationship itself follows from the SI prefix definitions. Use the page to translate numbers between instruments, drawings and spreadsheets, and keep the original reading and unit in the record.
Comparing parts on a datasheet
Datasheets for low-resistance parts mix the units freely. A power MOSFET may list an on-resistance of 3.5 mΩ, which is 3,500 µΩ, and a precision shunt may be sold as 100 µΩ. In ohms those are 0.0035 and 0.0001. Converting everything to one unit before comparing parts avoids reading 100 µΩ as larger than 3.5 mΩ just because 100 is the bigger number. The resistance of the board traces and connectors in series can exceed these values, so the total current path matters more than any single part.