The prefix switch inside one datasheet
Low-resistance parts are specified in whichever unit gives a tidy number. A power MOSFET lists on-resistance as 4.5 mΩ. A current-sense shunt lists 0.5 mΩ. A busbar joint test sheet lists 85 µΩ. A lithium cell datasheet lists internal resistance as 30 mΩ. Anyone adding the series resistance of a power path has to bring all of these to one unit before summing, and a thousand-fold slip is easy when two prefixes sit in neighboring columns. This page converts microohms to milliohms, so a joint of 85 µΩ becomes 0.085 mΩ, small against the 4.5 mΩ of the transistor it connects to, yet worth knowing when several joints add up.
One thousand, three decimal places
A milliohm is 10⁻³ Ω and a microohm is 10⁻⁶ Ω, so mΩ = µΩ × 0.001. A reading of 850 µΩ is 0.85 mΩ, 4,500 µΩ is 4.5 mΩ and 120 µΩ is 0.12 mΩ. This is the most forgiving conversion in the micro family, because only three places move and the numbers stay readable without scientific notation. The SI Brochure lists milli as 10⁻³ and micro as 10⁻⁶. The default 10 µΩ produces 0.01 mΩ, and the output may print as 0.009999999999999998, which is a floating-point display of 0.01. Use whichever rounding fits your instrument resolution.
The 10 µΩ default against real parts
Ten microohms, or 0.01 mΩ, is below the resistance of nearly every component. A good crimped lug might measure 50 to 200 µΩ, a bolted busbar joint may come in at a few tens of microohms, and a fuse typically sits in the milliohm range or above. A 10 µΩ value therefore describes an excellent connection or a short length of heavy conductor. With a 100 A load the voltage drop across 10 µΩ is 1 mV, and the heat is 0.1 W. Those figures show why low-resistance joints matter for high-current systems, and why measuring them demands a four-wire method instead of an ordinary multimeter.
Adding up the path in an EV or power pack
Suppose a battery pack path contains two cell tabs at 120 µΩ each, a busbar joint at 85 µΩ, a fuse at 1.2 mΩ and a contactor at 0.4 mΩ. Converting the microohm items gives 0.12, 0.12 and 0.085 mΩ, which together are 0.325 mΩ. The total path is 1.925 mΩ. At 200 A, the drop is 0.385 V and the heating is about 77 W. The joints contribute under 17 percent of the total, a figure that tells a designer where the bigger savings lie. Doing the sum in one unit avoids the classic slip of adding 120 to 1.2 as though they shared a prefix.
MOSFET on-resistance and sense resistors
A MOSFET with 4.5 mΩ of on-resistance is equal to 4,500 µΩ, and a sense shunt with 0.5 mΩ is 500 µΩ. The PCB copper that links them might add 800 µΩ, depending on trace length and thickness. Placing the numbers in the same unit shows that the board copper is comparable to the shunt itself, a result that affects the accuracy of a current measurement. Datasheets for shunts usually warn that the connection resistance matters at this scale, and Kelvin sensing is the standard remedy. The conversion tells you how big the problem is in the common unit, and the layout decision follows from the number.
Cell internal resistance and pack matching
Battery makers and hobbyists who build packs from cylindrical cells match cells by internal resistance. A reading from an AC internal-resistance meter might show 24 mΩ for one cell and 27 mΩ for another. An instrument that exports in microohms prints 24,000 and 27,000. Dividing by 1,000 by hand is easy, but a list of forty readings invites a slip, so convert the column with this page or a spreadsheet factor of 0.001. A spread of 3 mΩ within a series string is often the difference between a balanced pack and one that heats unevenly. The conversion makes the spread visible in the unit specified by the cell datasheet. Remember that the internal resistance changes with temperature and state of charge, so compare readings taken under the same conditions, and note the measurement frequency of the meter, often 1 kHz for AC methods.
Reading a micro-ohmmeter correctly
A micro-ohmmeter injects a DC current, often 10 A or more, and measures the voltage across the joint with separate sense leads. The result in microohms is the joint resistance without the lead contribution. Because the meter displays up to a few thousand microohms on its lowest range, a reading of 2,400 µΩ and one of 2.4 mΩ describe the same joint. Technicians sometimes quote the second form in reports because milliohms look familiar. Both are valid, and this page changes one into the other. Record the test current alongside the value, because contact resistance can vary with current and surface condition. Repeat the measurement after reversing the current direction when the meter supports it, since thermoelectric voltages at a joint can bias a single reading, and average the two for a steadier figure.
Rounding rules for small resistances
When you convert, keep as many digits as the instrument resolved and no more. A meter with 1 µΩ resolution that reads 847 µΩ gives 0.847 mΩ, and writing 0.8470000 mΩ suggests resolution the meter lacks. If you add several converted values, carry one extra digit through the sum and round at the end. A total such as 1.925 mΩ from inputs with two or three significant digits should be reported as 1.9 mΩ. Following this rule keeps a design review from arguing over digits the measurements cannot support. The converter itself does not round beyond floating-point storage, so the decision rests with you.
What the conversion cannot tell you
The page does not know whether a resistance is acceptable, and it cannot account for temperature, contact pressure, oxidation or the measurement current. It does not convert resistivity or sheet resistance. Because one milliohm is exactly 1,000 microohms, the output is exact apart from display noise. For larger units, use the ohm, kiloohm and megaohm pages. For acceptance criteria, check the standard or the manufacturer limit for the specific joint or part, and use this page only to put readings from different sources into the same unit. Keep in mind that a single milliohm of added resistance in a 200 A circuit costs 40 W, so small numbers can still have large consequences once the current is known.