Ground data and model inputs
Field instruments, radio coverage maps and soil surveys often give conductivity in mS/m, because typical ground values are a few to a few hundred of them. Electromagnetic simulation software and physics texts expect S/m. This page makes the step between the two. Enter the mS/m value, keep S/m as the target and read the number that goes into the model. Because both units are per meter, the length does not change and the factor is a plain one thousand. The page restates a conductivity in another unit and does nothing else. It does not interpret a survey, predict signal range or check a design against any rule.
Removing the milli prefix
The prefix milli means 10^-3, so 1 mS/m is 0.001 S/m and S/m = mS/m × 0.001. The siemens is the SI unit of electrical conductance, one ampere per volt, and the BIPM SI Brochure lists the prefix. The factor is defined and carries no uncertainty. Moving the decimal point three places to the left gives the result: 500 mS/m becomes 0.5 S/m, and 30 mS/m becomes 0.03 S/m. The result is always smaller than the input by a factor of 1,000. If your answer is larger, the menus are reversed. Keep the meter in the symbol, because S alone is conductance and S/m is conductivity, two different quantities. A value such as 3 mS/m is 0.003 S/m, and 3 mS without the meter would be a different quantity altogether.
Ten mS/m is 0.01 S/m
The default input of 10 mS/m returns 0.01 S/m. This is a useful anchor for the earth: the reciprocal, 100 ohm-meters, is a resistivity that grounding designers meet in ordinary moist soil. The step from conductivity to resistivity is a division, so 0.01 S/m corresponds to 1 / 0.01 = 100 ohm-meters, and 0.1 S/m to 10 ohm-meters. Soil varies widely with moisture, temperature, clay and salt content, and a single site can change several-fold over a year, so the example only illustrates the arithmetic. Dry sand or rock can reach thousands of ohm-meters, which is below 1 mS/m, while wet clay can fall to a few tens of ohm-meters. A real grounding design takes measured resistivity at the site, taken by a qualified person with the method the standard prescribes.
Radio ground conductivity maps
The propagation of medium-wave broadcasts along the ground depends on how well the ground conducts. Broadcast regulators publish ground conductivity maps in mS/m, and the ITU publishes an atlas of ground conductivity with values in S/m and mS/m. Poor ground in dry, rocky regions might be 1 to 3 mS/m, which is 0.001 to 0.003 S/m, while good agricultural land may be 10 to 30 mS/m. Sea water is near 5,000 mS/m, or 5 S/m. Those values are rounded orientation figures. For a coverage study use the regulator map or the ITU recommendation for your area, and use this page only to put the numbers in the unit your propagation software wants.
Electromagnetic survey readings
Induction surveys for soil mapping, archaeology and groundwater prospecting report apparent conductivity in mS/m. A reading of 80 mS/m is 0.08 S/m, and 5 mS/m is 0.005 S/m. The reading is a weighted average over a volume of ground and depends on coil spacing and orientation, so it does not equal the conductivity of any one layer. If you pass survey values into an inversion program, check which unit it expects before you load the file, because a wrong unit shifts every value by a factor of 1,000 and produces a model that looks plausible but is wrong everywhere. The page does not perform inversion or calibrate an instrument. Many survey programs export both mS/m and S/m versions of a grid, and the file header or the color bar legend states which one a given map uses, so read it before you merge grids from different sources into one project.
Back from S/m to mS/m
To convert in the other direction, choose S/m as the source and mS/m as the target. A value of 0.5 S/m equals 500 mS/m, and 5 S/m equals 5,000 mS/m. Multiply by 1,000. This direction is handy when a simulation output or a material table gives S/m and an instrument sheet uses mS/m. The factor works for any value, so 0.0005 S/m equals 0.5 mS/m. Round trips are a good test: convert 40 mS/m to 0.04 S/m and back, and the starting value must return. Writing the factor as a named constant in a spreadsheet makes the formula readable, and it helps later when someone wonders why a column was multiplied by 1,000.
Water and soil extracts
Fresh drinking water has a conductivity of tens to a few hundred mS/m at the high end, so a tap sample of 40 mS/m is 0.04 S/m, which equals 400 µS/cm on a handheld meter. A soil extract of 200 mS/m is 0.2 S/m and 2 dS/m, a unit used in agronomy where 1 dS/m equals 100 mS/m. Whether a given water or soil is acceptable for a purpose depends on the standards of the field, which are not part of this page. The conversion ties together the units of laboratories, agronomists and engineers so that a report in one unit can be read by someone who works in another.
Temperature and frequency
The conductivity of an electrolyte rises with temperature by around 2 percent per degree Celsius, and the conductivity of ground and tissue depends on the measuring frequency. A reported value is tied to the conditions of its measurement. Water meters refer values to 25 °C, and some methods use 20 °C. The unit conversion leaves those conditions unchanged. When you carry a value into a model, copy the reference conditions with it, and compare values only if they share them. Data from two instruments at different frequencies can differ for physical reasons that have nothing to do with units. Add the date of the measurement as well, since soil moisture after rain can raise ground conductivity several-fold within days.
Sensor accuracy behind the S/m value
The page only rescales a conductivity in mS/m to S/m. It does not compensate for temperature, interpret a survey, design a ground system, predict radio coverage or judge compliance with a limit. For those tasks use the method standards, regulator data and the advice of a qualified professional, and keep the original reading beside the converted one.