Why instruments report in picoamperes
Some of the most sensitive electrical measurements in science are currents so small that even a nanoampere is a large reading. Electrophysiologists record the current through a single ion channel in a cell membrane, and the signal is in the picoampere range. Mass spectrometers and photomultiplier tubes produce picoampere-level output currents in some operating conditions. Electrometers and picoammeters display readings directly in pA. A user who has a result in nA from one instrument and a limit in pA from another needs a quick conversion, and that is what this page offers. It multiplies by 1,000 and leaves the physical current untouched. It does not model noise, the limits of an instrument or the accuracy of a measurement, so the input should be a value you have already measured or specified.
The factor and the default result
Nano stands for 10^-9 and pico for 10^-12, so the picoampere is a thousand times smaller than the nanoampere. The same current therefore appears as a number a thousand times larger. The page formula is pA = nA × 1,000. With the default 10 nA, the result is 10,000 pA. A value of 0.35 nA becomes 350 pA, and 2.2 nA becomes 2,200 pA. Going back, 5,000 pA is 5 nA. The factor is exact because both prefixes are defined as powers of ten by the International System of Units, and NIST Special Publication 811 lists them. No rounding appears in the arithmetic. If the output ever shows a different number of digits from what you expect, check that the right target unit was selected before suspecting the factor.
Single ion channels and the patch clamp
In the patch-clamp technique, a glass pipette seals onto a small patch of cell membrane and a sensitive amplifier records the current that flows through the ion channels in the patch. The current through a single open channel is typically on the order of a few picoamperes at physiological voltages, and the whole-cell currents range from hundreds of picoamperes to nanoamperes. A recording that shows steps of 2 pA is therefore the signature of channels opening and closing, and a whole-cell current of 1.5 nA is 1,500 pA. Papers in the field use both units, depending on the preparation. This page does not interpret physiological data. It supports the reading of figures when a method section uses nA and a figure axis uses pA, or the other way around.
Photodiodes, dark current and detectors
A photodiode produces a current proportional to the light falling on it, and when it is dark a small leakage called the dark current remains. For a silicon photodiode the dark current can be a few picoamperes to nanoamperes depending on size and temperature, and it rises with temperature. A detector with a dark current of 0.8 nA has 800 pA of offset, which limits how weak a signal it can resolve. The signal current from a photodiode that receives 5 nW of light with a responsivity of 0.5 A/W is 2.5 nA, or 2,500 pA. These numbers are examples for illustration. They show how both units are used for the same device, with nA for the signal and pA for the leakage that competes with it.
Reading charge and counts from picoamperes
A current is a flow of charge, and at the picoampere level you can think of the flow as individual particles. One ampere is one coulomb per second, and one elementary charge is 1.602176634 × 10^-19 coulomb. A current of 1 pA therefore corresponds to about 6.24 million elementary charges per second, since 10^-12 divided by 1.602 × 10^-19 is about 6.24 × 10^6. A current of 10 nA, which is the default, is 10,000 pA, which means about 62 billion charges per second. In an ion detector, a current of a few picoamperes means millions of ions arriving every second. Converting between nA and pA helps you scale such counts to your own data without losing track of orders of magnitude, since 1 nA contains a thousand times the flow of 1 pA.
A worked comparison of two leakage specs
Two analog switches are listed with off-state leakage currents. The first is specified at 0.12 nA at room temperature and the second at 90 pA. Which is lower? Converting the first to picoamperes gives 0.12 × 1,000 = 120 pA, which is higher than the second device's 90 pA. The second part leaks about 75 percent as much as the first. At high temperature, both numbers may be many times larger, so the comparison is only valid under the same conditions. Both parts are hypothetical examples. The principle is the same for any pair of specifications: bring them into a single unit before deciding. Picoamperes work well here because neither value needs a decimal point once converted.
Cables, insulation and why small currents are hard
Measuring a picoampere is difficult because the world is full of stray currents of that size. Insulation resistance, surface contamination, humidity and static charge can create leakage paths in a circuit board or a cable. A leakage path of 100 gigohms with 10 V across it carries 100 pA. Moving a coaxial cable can generate a triboelectric current, and changes in capacitance produce displacement currents. Engineers use guarding, triaxial cables, clean insulators and shielding to keep these effects below the signal. Because the unit scale changes so much between a normal circuit and a low-current measurement, a conversion tool prevents slips when reading a specification. When a manual says that cable noise is 20 pA and your signal is 3 nA, converting the first to 0.02 nA or the second to 3,000 pA puts them on common ground.
Going down to femtoamperes
The next step down is the femtoampere, one thousandth of a picoampere. The converter lists femtoamperes among its units, so 10 nA is 10,000,000 fA. Very high-end electrometers can resolve currents in the femtoampere range, though only in carefully designed setups with extensive shielding. Leakage in modern transistors in the off state can also be quoted in femtoamperes per micrometer of width in research papers. The sequence from ampere to milliampere, microampere, nanoampere, picoampere and femtoampere spans fifteen orders of magnitude, from the current in a starter motor circuit to the trickle in a gate dielectric. The conversion on this page covers one step of a thousand, and the same logic applies to every neighboring pair of prefixes.
Common mistakes
Because the factor is a thousand in both directions, it is easy to apply it the wrong way. Going from nanoamperes to picoamperes the number must grow, so 10 nA should be 10,000 pA, and a result of 0.01 means the direction is reversed. Another mistake is to confuse pA with µA when typing a symbol. A pA is a millionth of a µA, and the difference is not recoverable from the number alone. People sometimes also read pA as picoampere-hours. Finally, avoid rounding a figure before converting. A value of 0.354 nA is 354 pA, and rounding to 0.35 nA first would give 350 pA and lose information. Convert at full precision and round at the end if you must.
Electrometer ranges and what they display
Electrometers and picoammeters often switch between decades of range, and the display unit changes with them. The same 0.8 nA may be shown as 800 pA when an auto-ranging instrument changes its display scale. When you log data from such a device, a file can contain a mixture of nA and pA values, and a conversion step is needed before you plot them. Suppose a log shows 1.2 nA, 950 pA and 0.4 nA in sequence. In picoamperes these are 1,200, 950 and 400. The ordering is clear at once, which was not obvious with mixed units. Always record the unit in the column header or in each entry, so that an analysis script or a colleague can reconstruct the scale later.
Noise floors and the signal you can resolve
Every current measurement has a noise floor, often quoted in picoamperes or femtoamperes. A picoammeter with a noise level of 20 pA peak to peak cannot resolve a signal change of 10 pA, but it can see a change of 1 nA, which is 1,000 pA, with a comfortable margin. The ratio of signal to noise in this case is 50 to 1. Averaging reduces random noise in proportion to the square root of the number of readings, so 100 readings cut the noise by a factor of 10. Converting everything to picoamperes before you compare signal and noise avoids a unit mismatch. The numbers are illustrative, and the instrument manual gives the figures that apply to a specific device, including its bandwidth and the integration time at which they were measured.
Time scales and integrated charge
A current also carries charge over time, and picoamperes build up slowly. A steady 10 nA, which is 10,000 pA, moves 10 nanocoulombs every second. A steady 250 pA moves 250 picocoulombs per second, so after 40 seconds it has delivered 10,000 picocoulombs, or 10 nC, the same charge that 10 nA delivers in one second. This relation is why integrating detectors, such as a charge amplifier on a weak source, can recover faint signals by collecting for a longer time. The arithmetic only requires that the current and the time are in compatible units. Convert nanoamperes to picoamperes first if the capacitor or charge scale you work with is in picocoulombs. The example numbers are chosen for illustration and do not refer to any device.
Scope and sources
The page converts between SI-prefixed units of electric current. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and nothing here is a statement about safety or measurement accuracy. The definitions of the ampere and the prefixes come from the BIPM SI Brochure and NIST Special Publication 811. For a real measurement, the instrument documentation defines its range, resolution and uncertainty, and those details matter far more than the arithmetic of the prefix change. Use the converter for a clean scale change, then apply the engineering judgment that the application requires.