Neighbors on the low end of the scale

The femtoampere and the picoampere are adjacent prefixes, and the work that uses them overlaps. Picoammeters, electrometers and low-noise amplifiers cover both, and a datasheet may give one specification in fA and the next in pA. A reader who sees an input bias of 3 fA on one page and a leakage of 0.4 pA on another has to put them in one unit before deciding which is larger. This page does that with a single factor of 1,000. It is the most direct conversion in the femtoampere family, and the one most often needed when comparing low-current specifications side by side. Typical readers are electronics engineers, biophysicists and lab technicians, who all meet specifications written with both prefixes, often in the same table.

Femto and pico differ by a thousand

Femto is 10^−15 and pico is 10^−12, so one picoampere equals 1,000 femtoamperes, and one femtoampere equals 0.001 pA. Converting from fA to pA divides by 1,000, which the page does by multiplying by 0.001. The prefixes and their values come from the BIPM SI Brochure, so the factor is exact. If the output shows digits such as 0.010000000000000002 for the default, they are binary floating point noise and the value is 0.01 pA. Rounding to the precision of your input removes them. The same factor converts any figure in a table, so a column of fA readings from a leakage test can be restated in pA in one pass, with 3,300 fA becoming 3.3 pA and 450 fA becoming 0.45 pA.

The default of 10 fA

The page starts with 10 fA, which is 0.01 pA. Put differently, 10 fA is one hundredth of a picoampere, so a current of this size would be invisible to an instrument with a picoampere resolution. That is a practical point for anyone buying or setting up a meter: a device that resolves 0.1 pA cannot see a 10 fA signal, and the specification should list a noise floor and a resolution in the unit that matches the job. Doubling the input to 20 fA gives 0.02 pA, and 1,000 fA gives exactly 1 pA. A rule of thumb is to move the decimal point three places: 10 fA becomes 0.010 pA, and 0.4 pA becomes 400 fA.

Patch-clamp recordings

Electrophysiologists measure current through single ion channels in cell membranes, and those currents are of the order of a picoampere to a few picoamperes, with whole-cell currents reaching nanoamperes. A channel current of 4.7 pA is 4,700 fA, and the noise of the recording setup may be a few tenths of a picoampere, or hundreds of femtoamperes. Seeing both units in one paper is normal. When a methods section lists the amplifier noise in fA and the signal in pA, this page puts them on one scale, so you can judge the signal-to-noise ratio of a recording at a glance. A channel with a conductance of 20 picosiemens at 100 mV carries 2 pA, and recordings are filtered to a few kilohertz to bring the noise below that level.

Input bias current of amplifiers

Operational amplifiers list input bias current, the small current flowing into each input. General-purpose bipolar parts have bias currents in the range of tens or hundreds of nanoamperes. JFET-input parts are lower, typically a few tens of picoamperes at room temperature, and electrometer-grade amplifiers go down to femtoamperes. Comparing a part with 30 pA with one with 250 fA means converting: 30 pA is 30,000 fA, which is 120 times larger. Bias current roughly doubles for every 10 °C rise in junction temperature on JFET devices, so datasheet values at 25 °C understate what you would see in a warm enclosure. Read the temperature at which the bias figure is specified, and compare maximum with maximum and typical with typical.

Leakage on a circuit board

A board that carries a high-impedance node has to keep the leakage from its own surface well below the signal. A contaminated, humid board can leak nanoamperes, which swamps a picoampere signal entirely. Designers use guard rings, which surround the sensitive node with a conductor at the same voltage so that no voltage difference drives leakage across the board surface, and they clean boards carefully and sometimes mount the input on a PTFE standoff. A target such as keeping leakage under 100 fA, which is 0.1 pA, is a reasonable design goal for an electrometer input and a realistic way to use this page. Cleaning with isopropyl alcohol and a bake before assembly is common practice for such nodes, and conformal coating can seal the board against humidity.

Going from picoamperes to femtoamperes

Select pA as the From unit and fA as the To unit to go in the other direction. A reading of 0.8 pA is 800 fA, and 1 pA is 1,000 fA. A noise specification of 0.25 pA RMS converts to 250 fA RMS, and 1.5 pA is 1,500 fA. This direction is common when a measurement is displayed in picoamperes and a specification asks for a limit in femtoamperes. As with other conversions in this family, the multiplication does not change the uncertainty of the original reading, so a meter accurate to one percent of reading stays accurate to one percent after conversion.

Averaging and resolution

Instrument displays usually show more digits than the measurement supports. A picoammeter that displays 4.7312 pA does not provide femtoampere accuracy at the fifth digit, and converting to 4,731.2 fA adds no information. Averaging many readings reduces random noise, roughly with the square root of the number of samples, but it does not remove offset errors or drift. Report the converted value with the digits that the instrument specification justifies, and state the averaging time, because for tiny currents the measurement bandwidth matters as much as the number itself. A longer integration time lowers noise at the cost of response speed, so a result quoted without its bandwidth cannot be compared with another.

Instrument noise and measurability are not judged

The page converts one unit to another. It does not judge whether a current is measurable with your instrument, what noise a setup will have, or whether a circuit meets its specification. It does not calculate installation limits, equipment ratings, protection, material response or compliance. Those depend on the instrument manual, the circuit and the conditions under which the original number was obtained.