MEASUREMENT & METHODS

Picosiemens (pS): conductance unit guide

pS expresses conductance using pico.

Measurement basis

Its reference factor is 10^-12 S.

Definition conventions

Mho is another name for siemens. The selections change conductance units only.

Conversion method

Multiply pS by 10^-12 for siemens.

Reference equivalent of pS

1 pS = approximately 1e-12 S.

Recorded scale factors: 1e-12 for pS; 1 for S.

Worked example

Known input: 10 pS. Reference equivalent: 1e-11 S. The return conversion gives approximately 10 pS.

The example retains conductance rather than conductivity.

Common reference values

Input (pS)Reference equivalent (S)
11e-12
55e-12
101e-11
252.5e-11
505e-11
1001e-10

Compare one pS with other units

Target unitEquivalent of 1 pSDefinition guide
Siemens (S)1e-12Read definition
Millisiemens (mS)1e-9Read definition
Microsiemens (µS)0.000001Read definition
Nanosiemens (nS)0.001Read definition
Kilosiemens (kS)1e-15Read definition

A conductance of one trillionth of a siemens

The picosiemens, symbol pS, is 10⁻¹² siemens. The siemens is the SI unit of electrical conductance, the inverse of resistance, and one siemens equals one ampere per volt or one reciprocal ohm. In base units it is kg⁻¹·m⁻²·s³·A². A conductance of 1 pS corresponds to a resistance of 10¹² Ω, which is one teraohm. The unit appears in cell physiology and in electrometry, where conductances are small enough that resistances are quoted in gigaohms or teraohms. Writing 1 pS rather than 1 TΩ lets additive effects be summed directly, because parallel conductances add while parallel resistances do not, and that is the convenience that made conductance units popular among neuroscientists. Ten identical 20 pS channels open together give 200 pS, and the whole-cell conductance is found by adding them, with no reciprocals needed.

Single ion channel conductance

Patch clamp recordings measure how much current a single channel passes at a given voltage, and the slope, I divided by V, is the channel conductance in picosiemens. A current of 5 pA at 100 mV gives 50 pS. Many voltage-gated sodium channels measure around 20 pS, potassium channels from about 10 to 20 pS up to hundreds for large-conductance types, and the nicotinic acetylcholine receptor near 40 to 60 pS. These figures differ with ion concentrations, temperature and the species of channel, so a quoted number applies to its own recording conditions. The unit makes it easy to compare channels that carry currents of a few picoamperes at different voltages, since conductance removes the voltage from the description.

Gigaohm seals in picosiemens

A good patch clamp seal between pipette and cell membrane has a resistance above 1 GΩ, which is 1 nS or 1,000 pS. A seal of 10 GΩ gives 100 pS of leak conductance, and 100 GΩ gives 10 pS. A leak of 100 pS at 100 mV carries 10 pA, a value comparable to the signal of one channel, so seal quality sets the noise floor. Experimenters therefore chase seals of tens of gigaohms, which correspond to leak conductances of tens of picosiemens. The inverse relation makes it easy to see why a seal improvement from 1 GΩ to 10 GΩ is worth the effort, since the leak conductance falls tenfold, from 1,000 pS to 100 pS.

Insulation resistance and leakage

The same unit applies to insulators. A capacitor dielectric or printed circuit board with an insulation resistance of 100 GΩ has a leakage conductance of 10 pS. Insulation resistance specifications for high-quality film capacitors reach into the teraohm range, so values near 1 pS. At 10 V, a 1 pS path leaks only 10 pA. Measuring such small conductances needs an electrometer, shielding and a dry environment, because humidity on a board surface can lower the resistance by orders of magnitude. Rubber, glass and PTFE hold their values better than paper or cardboard, which absorb moisture. Reporting the test voltage and humidity alongside the conductance is a habit worth keeping. A fixture whose leakage reads 20 pS at 50 percent humidity can read several times higher on a damp day, and subtracting a fixture blank measured with no sample attached is the standard way to isolate the part itself.

Conductance, conductivity and geometry

Conductance depends on the size and shape of the sample, while conductivity is a property of the material. The two are tied by G = κ × A / L, where A is cross-sectional area, L is length and κ is conductivity in siemens per meter. Ultrapure water at 25 °C has a conductivity of about 0.055 µS/cm, which is 5.5 µS/m. In a measuring cell with a geometry factor of 1 cm, that gives a conductance near 55 nS, or 55,000 pS. A value in pS therefore says nothing about conductivity until the cell constant is known. Conductivity probes are rated in µS/cm, and the picosiemens figure belongs to a single sample or a single channel.

Converting along the siemens ladder

Step factors are powers of ten. Siemens to Picosiemens multiplies by 10¹², Millisiemens to Picosiemens by 10⁹, Microsiemens to Picosiemens by 10⁶, Nanosiemens to Picosiemens by 1,000 and Kilosiemens to Picosiemens by 10¹⁵. In the other direction, Picosiemens to Nanosiemens multiplies by 0.001, to Microsiemens by 10⁻⁶, to Millisiemens by 10⁻⁹ and to Siemens by 10⁻¹². A conductance of 250 pS is 0.25 nS, and 0.000000000250 S. The old name for the unit, the mho, has the same size as the siemens, so 1 mho equals 1 S. Because the factors are only decimal shifts, the typical error is miscounting zeros, and writing the value in scientific notation prevents it.

Naming, history and the 1971 decision

The unit honors Werner von Siemens, the German engineer and industrialist who founded the electrical firm that bears his name. The General Conference on Weights and Measures adopted the name siemens for the reciprocal ohm in 1971, replacing the older mho in SI texts. The symbol is a capital S, and a lowercase s would mean seconds. This matters at the picoscale. The symbol pS stands for picosiemens, while ps stands for picosecond, and the two differ only by case. A datasheet that lists 10 pS and 10 ps may be talking about a leakage and a delay time. Reading the case of both letters is the way to separate them in plain text, and search engines often ignore it. The same caution applies to nS and ns, where nanosiemens and nanoseconds differ by one letter case.

Limits of a conductance number

Many biological and electronic conductances are not constant. A channel conductance often depends on voltage, and a diode or insulator may deviate from Ohm law at higher fields, so a figure in picosiemens applies to the stated voltage range. Where the current-voltage curve bends, the slope conductance at one point differs from the chord conductance, which is I divided by V. Noise sets limits as well. The thermal current noise of a conductance G is the square root of 4kTG per hertz, and for 100 pS at 300 K that is about 1.3 fA per root hertz, so a 10 kHz bandwidth gives roughly 0.13 pA rms. Cite the method, the voltage and the temperature, and keep significant digits consistent with the original measurement.

Precision and checking

  • Keep source conductance resolution.
  • Retain pS without adding a length denominator.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.