Two ends of a conductance table

Conductance is the reciprocal of resistance, and the range it covers in practice is enormous. A neuroscientist reading a single ion channel works in picosiemens. A power engineer comparing the contact of a busbar joint or a battery cable works in siemens, and sometimes in kilosiemens when the resistance is a milliohm or less. A table that spans both, or a script that stores every conductance in one unit, needs the conversion between the two prefixes. This page multiplies a picosiemens value by 10^-15 and returns kilosiemens. The answer is nearly always a small number, so it appears in scientific notation, which keeps the digits readable. Measurement uncertainty is a separate matter: a value of 10 pS from a bench instrument may carry several percent of error, and the converted figure inherits it.

The siemens and fifteen places

The siemens is one ampere per volt, the reciprocal of the ohm. Pico is 10^-12 and kilo is 10^3, so one kilosiemens equals 10^15 picosiemens, a quadrillion. The formula is kS = pS × 1e-15, and the factor is exact because both prefixes are defined values in the SI Brochure. By hand, move the decimal point fifteen places to the left. A conductance of 25 pS is 2.5 × 10^-14 kS, and one of 500,000,000,000,000 pS is 0.5 kS. A two-step route also works: divide by 10^12 to get siemens, then by 1,000. The two steps must multiply back to 10^15.

A leakage path of ten picosiemens

The page starts with 10 pS, which gives 1 × 10^-14 kS. As a resistance, a conductance of 10 pS is 1 ÷ 10^-11 S, or 100 gigaohms. A leakage path of that size lies between two conductors that are meant to be isolated from each other, for example the surface of a circuit board around a high-impedance input. The comparison with kilosiemens makes the scale visible: ten picosiemens is a hundred-quadrillionth of a kilosiemens, and no meter reads both ends of that range. If a result is larger than the input after you convert, the units were entered in the wrong order.

Single ion channels in patch-clamp work

Recordings from a single ion channel report the conductance of the open channel, and values from about ten to a few hundred picosiemens are common in the literature. A channel at 25 pS is 2.5 × 10^-14 kS, and it corresponds to a resistance of 40 gigaohms. Researchers rarely need the kilosiemens, but a database that holds channel conductances beside whole-cell and tissue values may standardize on one unit. In that case the conversion is routine, and the exponent should be stored with the number. Comparing a channel with a whole cell, whose conductance sits in nanosiemens, uses the same idea at a smaller distance. An illustrative whole cell at 2 nS is 2 × 10^-12 kS, about a hundred times the figure for a 25 pS channel in picosiemens terms.

A busbar joint at two milliohms

At the other end, a bolted joint on a busbar with a resistance of 2 mΩ has a conductance of 500 S, which is 0.5 kS. In picosiemens that is 5 × 10^14 pS. Conductance is a natural way to describe parallel paths, because parallel conductances add directly: two joints of 0.5 kS each carry 1 kS together. The number is less common on a drawing than the resistance, which is why most engineers convert it back to milliohms. A conductance of 1 kS is a resistance of 1 mΩ, a useful anchor for the scale. The converter does not judge whether a joint resistance is acceptable. A battery cable run of 0.25 mΩ would be 4 kS, which shows how quickly the numbers grow when resistances shrink.

Adding conductances in parallel

Parallel paths simply add. If one leakage path carries 10 pS and another 25 pS, the combined conductance is 35 pS, or 3.5 × 10^-14 kS. Series paths work through resistances instead: two 200 pS paths in series give 100 pS, since each is 5 gigaohms and the pair is 10 gigaohms. A conductance table makes parallel sums easy and series sums awkward, while a resistance table does the opposite. Convert each value once, do the sum in the unit that suits the circuit, and then convert the total with this page. Keeping all values in picosiemens during the arithmetic avoids repeated rounding. For three paths of 10, 25 and 40 pS the parallel total is 75 pS, or 7.5 × 10^-14 kS.

Conductance and conductivity are different quantities

A conductance in siemens belongs to a particular object with a particular shape. Conductivity is a property of a material and is written in siemens per meter or per centimeter. A probe in water, for example, reports a conductivity that already accounts for the cell geometry. This converter handles siemens only, and entering a value in S/cm or S/m would give a result that has no meaning for the stated unit. If your datasheet lists a per-length unit, convert the length part first, and keep the conductance and conductivity columns separate in any table you build.

Reading a conductance spec in a datasheet

Datasheets state insulation and leakage in several forms, and the conversion helps only if you know which one you hold. A leakage current at a test voltage gives a conductance by dividing current by voltage: 2 pA at 10 V is 0.2 pS, or 2 × 10^-16 kS. An insulation resistance in teraohms gives the reciprocal: 5 TΩ is 0.2 pS. A conductance per unit length, for example for a cable, needs the length before it becomes a single figure. Write down which form the sheet uses, convert it to a conductance in siemens, and only then apply this page. Doing it in that order avoids a mix-up between a quantity of the part and a quantity of the material.

Decisions a prefix change cannot make

The result restates a conductance in another prefix. It does not tell you whether an insulation level meets a standard, whether a joint will heat under current, or whether a channel recording is clean. Kilosiemens appears rarely outside tables that apply the prefixes consistently, so most readers will use the number only as a comparison. Check the exponent against a known case before relying on a list of results: 1 kS must give 10^15 pS. The same factor applies to every input, so a surprising answer almost always comes from a mistyped value or a reversed pair of units.