Fifteen powers of ten between two ends of conductance

Conductance measures how easily current flows, and the siemens is its SI unit. Practical values range over a huge span. A short heavy copper bar has a conductance of thousands of siemens, while a single ion channel in a cell membrane has a conductance of tens of picosiemens. This page converts across the whole span in one move: 1 kS equals 10^15 pS. The default 10 kS gives 10,000,000,000,000,000 pS, or 1 × 10^16 pS. The formula is pS = kS × 10^15. People use it when building a scale chart, checking that units are consistent in a derivation, or reporting a very high conductance in a unit that makes sense for a very low one. The result is a unit translation and does not describe any particular circuit or component.

The definition of the siemens

The siemens, symbol S, is the SI unit of electric conductance. One siemens is the reciprocal of one ohm, so it is the conductance of a conductor that carries one ampere at a potential difference of one volt. In SI base units that is A²·s³·kg^-1·m^-2. The unit is named for Werner von Siemens, and the 14th General Conference on Weights and Measures adopted the name in 1971 in place of the older mho. The prefixes kilo and pico are defined in the BIPM SI Brochure and in NIST SP 811 as 10^3 and 10^-12. Dividing the two gives 10^3 over 10^-12, which is 10^15. The ratio is exact, so there is no rounding in the factor. Both sides describe the same physical conductance, only in different-sized units.

The default example worked through

For 10 kS, the page multiplies by 10^15 and gets 10^16 pS. In stages, 10 kS is 10,000 S. Each siemens contains 10^12 pS, so 10,000 S contains 10^4 × 10^12 = 10^16 pS. A second example, 0.5 kS, equals 500 S, which is 500 × 10^12 = 5 × 10^14 pS, or 500,000,000,000,000 pS. A third, 0.001 kS, equals 1 S and so 1 × 10^12 pS. A fourth, 1 kS, is 10^15 pS, or one quadrillion picosiemens. Results of this size are shown in scientific notation by many tools, and the value is the same whichever way it is written. Group digits by threes when writing them out, and count the groups: 10^15 has five groups of three zeros after the leading 1.

Conductance and resistance

Conductance and resistance are reciprocals: G = 1/R. A conductance of 1 kS corresponds to a resistance of 1 mΩ, the order of a good heavy busbar joint or the on-resistance of a large power transistor. A conductance of 10 kS is 0.1 mΩ. At the other extreme, 1 pS corresponds to 10^12 Ω, or 1 TΩ, an insulation level reached by good dielectrics and measured with electrometers. A leakage conductance of 10 pS is 100 GΩ. The reciprocal relation means that the two ends of the page correspond to very low and very high resistance. This is one reason physicists like picosiemens for leakage: the number is small and moves in the same direction as the physical effect, whereas resistance in teraohms becomes large and awkward.

Where picosiemens are used

Picosiemens appear in cell physiology and in precision electronics. Patch-clamp recordings of single ion channels report unitary conductances typically from a few picosiemens to a few hundred, with values such as 10 to 100 pS common for many channels. Gate leakage of MOS devices, surface leakage between traces on a printed circuit board, and the loss of high-quality capacitors are expressed as very small conductances. In such uses the instrument is an electrometer or a picoammeter, and measurement itself requires guarding and shielding to avoid errors. The number you read on a conversion page does not reflect those practical difficulties. Take the units as labels, not as a promise that the quantity can be measured on your equipment or that a device is safe to use.

Where kilosiemens are used

Kilosiemens show up in low-resistance systems. A copper bar with a cross section of 100 mm² and a length of 1 m has a resistance near 0.17 mΩ, using the resistivity of annealed copper of about 1.72 × 10^-8 Ω·m, which is a conductance close to 5.8 kS. Large welding, battery and power-electronic connections have milliohm or sub-milliohm resistances. Conductance of such parts is not commonly quoted because resistance in milliohms is more familiar, but in conductance models, network analysis or finite element work the conductance form is standard. In a nodal analysis of a network, the conductance matrix has entries in siemens, and a short link may appear as thousands of siemens. These figures are illustrative; real values depend on temperature, geometry and contact quality.

Conductance, conductivity and similar names

Conductance is a property of an object, while conductivity is a property of a material. Conductivity is measured in siemens per meter, and the two are related through geometry: G = σA/L, with σ the conductivity, A the cross-sectional area and L the length. Ultra-pure water has a conductivity near 0.055 µS/cm at 25 °C, and seawater is about 5 S/m. Those are conductivities. This page converts conductance only, so entering a conductivity value in S/m and treating the output as pS leaves out the geometry. A related unit is the electrical admittance, also in siemens, which includes reactive parts in AC circuits. The page treats the value as a plain number. It does not distinguish conductance from admittance or susceptance.

Checking and rounding

Because the factor is an exact power of ten, the digits in the result match the digits of the input shifted by fifteen places. Your input carries a certain number of significant figures, and the output should carry the same. Reporting 1.00 × 10^16 pS for an input of 10.0 kS is better than 10,000,000,000,000,000 pS if the zeros are only placeholders. When you reverse the conversion to check, dividing by 10^15 should return the starting number. Software with limited precision can drop the lowest digits when the number gets very large, and at the 10^16 level a double-precision value is only good to the last digit or two. If a chain of conversions uses several steps, such as kS to S to pS, check each step and compare with the direct factor of 10^15.

The reverse direction and neighbors

To convert picosiemens to kilosiemens, switch the From and To units and the page divides by 10^15. Entering 5 × 10^14 pS returns 0.5 kS. The drop-down lists include siemens, millisiemens, microsiemens and nanosiemens, which give intermediate steps: 1 kS is 10^3 S, 10^6 mS, 10^9 µS, 10^12 nS and 10^15 pS. Each step down multiplies by 1,000. For measuring water quality, the typical unit is µS/cm, which is a conductivity, but readers sometimes confuse it with µS. When both a conductance and a conductivity appear in a document, label them carefully and keep the geometry factor in mind.

Scope and safety note

Entering 10 returns 10^16 pS, and nothing on the page says whether such a conductance is possible for a conductor, insulator or connection. Adequacy for a circuit is a matter for the manufacturer data sheets and the codes and standards where you work. The BIPM SI Brochure and NIST SP 811 define the siemens and the prefixes.

Worked example with a patch-clamp channel

A single ion channel with a unitary conductance of 25 pS is a typical figure in physiology. Written in kilosiemens, that is 25 × 10^-15 kS, or 2.5 × 10^-14 kS. A cell membrane patch with 40 such channels open in parallel has a conductance of 1,000 pS, or 1 nS. Parallel conductances add, so the total is simply 40 × 25 pS. In resistance terms, 25 pS corresponds to 1/(25 × 10^-12) = 4 × 10^10 Ω, which is 40 GΩ. With a membrane voltage of 100 mV across the channel, Ohm's law gives a current of 2.5 pA, since I = G × V = 25 × 10^-12 S × 0.1 V. This is a standard order of magnitude in electrophysiology. The numbers are for illustration and are not data for a specific channel. They show why picosiemens is the natural unit at one end of the page and kilosiemens at the other.

Common errors in prefix handling

With fifteen orders of magnitude between the units, a slip of one prefix produces an enormous error. Mixing up pS with nS is a factor of 1,000, and confusing kS with mS is a factor of a million. The capital S for siemens and the lowercase s for seconds are easy to confuse in plain text, so mS (millisiemens) and ms (milliseconds) look alike in many documents. A conductance quoted as 10 ms may mean 10 milliseconds in a timing context and 10 mS in a circuit context. Check the context before converting. Another error is to apply the resistance prefix directly: a resistance of 1 mΩ is 1 kS, but 1 MΩ is 1 µS, so a mega on the resistance side becomes a micro on the conductance side. Remember that reciprocals reverse the direction of the prefix, which is a good reason to convert to siemens first and apply prefixes second.

Adding conductances in parallel

Conductances in parallel add directly, which is why the unit is convenient for network analysis. A bank of ten identical busbar links each with a conductance of 2 kS has a total of 20 kS. If a leakage path of 5 pS sits in parallel, the total becomes 20,000 S plus 5 × 10^-12 S, which is still 20,000 S to any sensible number of digits, because the leakage is smaller by a factor of 4 × 10^15. The example shows why such extreme ranges rarely meet in one calculation. In series, the resistances add instead, so you convert each conductance to resistance, sum, and invert. A series chain of a 1 kS link (1 mΩ) and a 1 pS leakage element (1 TΩ) has a total resistance dominated entirely by the larger value, 1 TΩ plus 1 mΩ, and its conductance is essentially 1 pS. The illustration is idealized and ignores contact effects.