Measurement basis
A conductance-unit conversion does not establish the element or conditions needed to relate its value to resistance.
Definition conventions
Mho is another name for siemens. The selections change conductance units only.
Conversion method
Use the stored conductance-scale ratio for a value already expressed in this quantity.
Choose the conversion direction
Confirm a conductance symbol such as S or a prefixed siemens before choosing the target.
The siemens as the reciprocal of the ohm
Electrical conductance measures how easily current flows through a component. It is the reciprocal of resistance, G = 1/R, and the SI unit is the siemens (S), named after Werner von Siemens. One siemens equals one ampere per volt, or one reciprocal ohm. Older texts used the mho, ohm spelled backward, with the symbol ℧, and you may still find it on vintage equipment and in some tube data. The CGPM adopted the name siemens in 1971. A 100 Ω resistor has a conductance of 10 mS, a 1 kΩ resistor 1 mS and a 1 MΩ resistor 1 µS. A smaller resistance means a larger conductance, which is why a short circuit is described as having very high conductance and an open circuit as having none.
Prefixes from kilosiemens to picosiemens
Conductance spans a wide range, so prefixes are used across many decades. A kilosiemens equals 1,000 S and appears in power system studies. A millisiemens is 0.001 S, a microsiemens 10⁻⁶ S, a nanosiemens 10⁻⁹ S and a picosiemens 10⁻¹² S. The conversion chain is regular: 1 mS is 1,000 µS, which is 1,000,000 nS. Insulation resistance of 10 GΩ corresponds to a conductance of 0.1 nS, which is 100 pS. Beginners often confuse the prefix direction because a very large resistance gives a tiny conductance. Writing both values side by side helps, for example 2.5 MΩ is 0.4 µS, since 1 divided by 2,500,000 is 4 × 10⁻⁷ S.
Current from conductance and voltage
Ohm law in conductance form reads I = G × V. A load with a conductance of 5 mS across a 12 V supply draws 60 mA. Conductances in parallel simply add, which makes them convenient for branch calculations: 5 mS and 3 mS in parallel give 8 mS, equal to a resistance of 125 Ω. In series, the reciprocals add, mirroring the rule for resistors in parallel. Power dissipated is G × V², so the same 5 mS at 12 V dissipates 0.72 W. Conductance form is common in nodal analysis, where equations are written in terms of node voltages and conductances, and in circuit simulators, which handle conductance matrices internally.
Admittance, susceptance and alternating current
For alternating current, conductance is the real part of admittance Y, the reciprocal of impedance. Admittance has the form Y = G + jB, where B is susceptance, and all three are measured in siemens. A capacitor has pure positive susceptance and an inductor has negative susceptance, while a resistor contributes only conductance. This is why the same unit appears in filter design and in RF matching networks, where the imaginary part is key. Converting a siemens value is straightforward, but the number alone does not say whether it is conductance, susceptance or the magnitude of admittance. A label such as 25 mS for a transmission line often means the characteristic admittance, which is 1/Z₀, so a 50 Ω line has a characteristic admittance of 20 mS.
Conductance in electronics datasheets
Transistor datasheets quote transconductance, the change in output current per unit change in input voltage, in siemens, often millisiemens. A bipolar transistor biased at 1 mA collector current has a transconductance of about 38.5 mS at room temperature, a value close to Ic divided by 26 mV. Output conductance and leakage conductance appear in smaller units, such as µS and nS. The word conductance in these documents describes a small-signal slope, not a simple DC ratio, so the unit is the same while the meaning is different. When you convert 38.5 mS to 0.0385 S or 38,500 µS, the physical interpretation stays with the original parameter, and the conversion does not change what the figure represents.
The quantum of conductance
In nanoscale conductors, conductance comes in discrete steps. The conductance quantum, G₀ = 2e²/h, is about 77.48 µS, equivalent to a resistance of roughly 12.9 kΩ. Since the 2019 redefinition of the SI, both the elementary charge e and the Planck constant h have exact values, which makes G₀ exact in principle, and the von Klitzing constant h/e² is about 25,812.8 Ω. A single-atom gold contact conducts about one quantum, so 77.48 µS is a landmark in molecular electronics experiments. In biology, single ion channels are measured in picosiemens, typically tens of picosiemens per channel, and the membrane of a whole cell in nanosiemens. This breadth from picosiemens to kilosiemens shows why a unit converter is useful for this quantity.
Conductance versus conductivity
Conductance belongs to a particular object, while conductivity is a property of a material. A copper wire of a given length and cross-section has a conductance in siemens, and the copper itself has a conductivity in siemens per meter. They are related through geometry: G = σ × A / L, so a wire 10 m long with a cross-section of 2.5 mm² and a conductivity of 5.8 × 10⁷ S/m has a conductance of 14.5 S. Water analysis shows the same pairing: a probe measures the conductance of a sample between two electrodes and a cell constant converts it to conductivity. Confusing the two, or confusing S with S/m, produces answers that are off by a geometry factor and unit mismatches that no conversion can repair.
Symbols to keep apart
The symbol for the siemens is an uppercase S, while a lowercase s is the second. A reading of 5 S is five siemens and 5 s is five seconds. Because the unit is named after a person, the name is written in lowercase, siemens, though the symbol is capitalized, and the plural is siemens as well. The unit mho and its inverted omega symbol have been retired from SI use, although they survive in some legacy specifications. For precise work, refer to the BIPM SI Brochure for the definition and to IEC 60027 for letter symbols. When documents use the term conductance for what is really a conductivity, such as a water quality figure in µS/cm, read the unit rather than the word.
Measuring conductance of a sample
A simple way to find a conductance is to apply a known voltage, measure the current and divide. A test fixture drawing 2.4 mA at 6 V has G = 0.0024 / 6 = 0.4 mS, which is 400 µS and equals a resistance of 2.5 kΩ. For liquids and biological samples, an alternating test signal avoids electrode polarization, so conductance meters operate at a frequency such as 1 kHz. Contact resistance can dominate for very conductive samples, and leakage can dominate for very poor ones, so the result carries both effects. Reporting the value in siemens with the test voltage and frequency keeps the figure reproducible, and converting to millisiemens or microsiemens afterward only changes the scale.
Precision and checking
- Keep the original measurement precision.
- Retain the prefix and the same element/condition information.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Siemens (S)
Definition, reference values and linked conversions.
Millisiemens (mS)
Definition, reference values and linked conversions.
Microsiemens (µS)
Definition, reference values and linked conversions.
Nanosiemens (nS)
Definition, reference values and linked conversions.
Picosiemens (pS)
Definition, reference values and linked conversions.
Kilosiemens (kS)
Definition, reference values and linked conversions.
Use a working converter
- Electrical conductance converter
- Siemens to Millisiemens converter
- Millisiemens to Siemens converter
- Siemens to Microsiemens converter
- Microsiemens to Siemens converter
- Siemens to Nanosiemens converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.