Kilosiemens (kS): conductance unit guide

kS uses the kilo prefix for conductance.

Measurement basis

One kS corresponds to 1,000 S.

Definition conventions

Mho is another name for siemens. The selections change conductance units only.

Conversion method

Multiply kS by 1,000 for the reference.

Reference equivalent of kS

1 kS = approximately 1000 S.

Recorded scale factors: 1e3 for kS; 1 for S.

Worked example

Known input: 10 kS. Reference equivalent: 10000 S. The return conversion gives approximately 10 kS.

The calculation changes the conductance prefix.

Common reference values

Input (kS)Reference equivalent (S)
11000
55000
1010000
2525000
5050000
100100000

Compare one kS with other units

Target unitEquivalent of 1 kSDefinition guide
Siemens (S)1000Read definition
Millisiemens (mS)1000000Read definition
Microsiemens (µS)1000000000Read definition
Nanosiemens (nS)1000000000000Read definition
Picosiemens (pS)1000000000000000Read definition

Conductance in the thousands of siemens

The siemens is the SI unit of electrical conductance, the reciprocal of resistance, with 1 S = 1 A/V = 1 Ω⁻¹. The kilosiemens is 1,000 S, which equals 1 divided by a resistance of one milliohm. A kilosiemens therefore shows up where resistances are tiny: busbars, welding cables, battery interconnects, superconducting joints, and the on-state of power transistors. A power MOSFET with an on-resistance of 1 mΩ has a conductance of 1,000 S, or 1 kS, and a joint of 0.25 mΩ has 4 kS. Most everyday work uses siemens, millisiemens or microsiemens, which is why kS is rare. A household resistor of 100 Ω is only 0.01 S, and a typical 1 kΩ resistor is 1 mS, so the scale of kS is about a million times beyond ordinary component values. Reaching it takes a conductor that is short, thick and very good, so a value in kS is a sign that the measurement came from heavy-current hardware. The unit is listed on this site mainly so that conductance values from different scales can be reconciled in a single comparison.

From the mho to the siemens

Before the siemens, the unit of conductance was the mho, the word ohm spelled backward, written with an inverted omega symbol. The 14th General Conference on Weights and Measures adopted the name siemens in 1971, honoring the German engineer Werner von Siemens, and it entered the SI as the derived unit with symbol S. Older American texts and some power-electronics papers still use mho or ℧. The conversion is one to one, 1 mho = 1 S, so only the name changes. The capital S is mandatory in the symbol because the lowercase s means second, and a unit written as ks would be a kilosecond, not a kilosiemens. The prefix kilo follows the usual SI rule of 10³, giving 1 kS = 1,000 S = 1,000,000 mS.

Factors to the smaller siemens units

The converters for this unit run between kilosiemens and the smaller prefixes, with these exact decimal relationships: 1 kS = 1,000 S = 1,000,000 mS = 1,000,000,000 µS = 10¹² nS = 10¹⁵ pS. Going the other way, 1 S = 0.001 kS, 1 mS = 0.000001 kS, 1 µS = 10⁻⁹ kS, and 1 nS = 10⁻¹² kS. The factors are powers of 1,000, so each step of the prefix chain moves the decimal point three places. A conductance of 2.5 kS is 2,500 S, 2.5 million mS, and 2.5 billion µS. A value of 40 mS is 0.00004 kS. These conversions change only the scale. The result is still a conductance measured between the same two points, and nothing about the surrounding circuit is implied.

A copper bar as a conductance calculation

For a uniform conductor, conductance G = σ × A / L, where σ is the conductivity in S/m, A is the cross-section in m² and L is the length in m. The International Annealed Copper Standard fixes 100 percent IACS at a conductivity of 58.0 MS/m at 20 °C, equal to 5.80 × 10⁷ S/m. A 100 mm² bar is 1 × 10⁻⁴ m², so a 1 m length has G = 5.80 × 10⁷ × 10⁻⁴ / 1 = 5,800 S, or 5.8 kS, with a resistance of 0.172 mΩ. A 10 m run of the same bar has one tenth of the conductance, 0.58 kS. The example is for annealed copper at 20 °C and a uniform current, so real bars with contacts, joints and warmer temperatures conduct somewhat less.

Conductances in parallel simply add

The practical advantage of conductance over resistance appears with parallel paths, because conductances add directly while resistances combine through reciprocals. Three busbar paths of 500 S each, which is 0.5 kS, give 1.5 kS in total, or a resistance of 1 / 1,500 = 0.667 mΩ. Adding a fourth identical path brings the total to 2 kS, which is 0.5 mΩ. In a series chain the opposite is true: two 2 kS elements in series give 1 kS, since resistances of 0.5 mΩ each sum to 1 mΩ. The arithmetic is the same as for resistors with the roles of the quantities swapped. Writing parallel networks in siemens often gives shorter arithmetic when the resistances are very small, which is the situation where kS is used.

Measuring a conductance this large

A conductance of several kilosiemens means a resistance of a milliohm or less, which ordinary two-wire meters cannot resolve, because the lead and contact resistance is comparable to the thing being measured. Micro-ohmmeters use four-terminal sensing: one pair of leads carries a known test current, a second pair senses the voltage drop directly across the joint. A test current of 200 A across a joint of 50 µΩ produces 200 × 50 × 10⁻⁶ = 10 mV, and the conductance is 1 / (50 × 10⁻⁶) = 20,000 S, or 20 kS. Switchgear and busbar joints are commonly checked this way and reported as a resistance in µΩ. The kilosiemens is the same information expressed as the reciprocal.

Conductance, conductivity and admittance are different things

Conductance is a property of a particular object, measured in S. Conductivity is a property of a material, measured in S/m, and the lab figure for water quality is usually in µS/cm, where 1 µS/cm = 0.0001 S/m. A conductivity probe reading 500 µS/cm is therefore not a conductance of 500 µS, and neither should be converted into kS without the cell constant or geometry. At alternating current, admittance and susceptance are also quoted in siemens, with conductance as the real part of admittance. A reactive component adds susceptance even when the conductance in the same circuit is unchanged. The siemens label alone does not say which quantity is meant, so a figure in kS needs its description (conductance of a path, a device, a cable) to be interpreted correctly.

Reciprocal prefixes: kS against kΩ and mΩ

Because conductance is the reciprocal of resistance, prefixes invert when switching between the two. One kilosiemens equals a resistance of 1 mΩ, one siemens equals 1 Ω, one millisiemens equals 1 kΩ, and one microsiemens equals 1 MΩ. A 100 kΩ resistor therefore has a conductance of 10 µS, and a 0.5 mΩ shunt has 2 kS. Confusing the kilo in kS with the kilo in kΩ reverses the direction of the scale and gives a value off by a factor of 10⁶. A quick check is to remember that a large kS figure means very easy current flow, so the matching resistance must be tiny. When a meter reports in one quantity and a specification uses the other, convert through ohms and siemens first and apply the prefix last.

Precision and checking

  • Retain source conductance precision.
  • Keep kS as the unit label.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.