Conductance as the mirror of resistance
Conductance is the reciprocal of resistance, measured in siemens, and one siemens equals one ampere per volt. A kilosiemens corresponds to a resistance of one milliohm, and a microsiemens to a resistance of one megaohm. Conductance is the natural way to describe parallel paths, because conductances in parallel simply add. A kS value belongs to very low-resistance paths such as large busbars and welding cables, and a µS value to nearly insulating paths such as clean water or a leaky insulator. A single report that covers both ends needs the nine-decade conversion this page provides.
One billion microsiemens per kilosiemens
Kilo is 10 to the third and micro is 10 to the minus sixth, so one kS is 1,000,000,000 µS. The default of 10 kS is 10,000,000,000 µS. A value of 0.5 kS is 500,000,000 µS, and 2.5 kS is 2,500,000,000 µS. In reverse, 100 µS is 0.0000001 kS. As with other long conversions, check the digit count: each kS value gains nine zeros. A mistake of a factor of 1,000 is common when kS and mS are confused, so check that the menu has the right units.
From resistance to conductance
To go from resistance in ohms to conductance in siemens, take the reciprocal. A busbar joint of 2 mΩ has a conductance of 1 divided by 0.002, which is 500 S, or 0.5 kS, or 500,000,000 µS. A resistor of 1 MΩ has a conductance of 1 µS. A 10 kΩ resistor has 100 µS, which is 0.0000001 kS. Doing the reciprocal first and the prefix conversion second is the safest order. The page handles the prefix step only, so enter a conductance and not a resistance. A 0.1 Ω cable is 10 S, which is 0.01 kS or 10,000,000 µS, and a 50 Ω load is 0.02 S, which is 20,000 µS. Each result comes from the reciprocal first, and the prefix change second.
Water conductivity and cell constants
Conductivity meters measure the conductance of a probe immersed in a sample and report conductivity in µS/cm or mS/cm. Conductivity is conductance times the cell constant, which is the ratio of electrode spacing to area. A cell with a constant of 1 per centimeter that measures 500 µS shows a conductivity of 500 µS/cm. A different cell constant changes the reported value. The two quantities are related but not the same, and the unit µS alone describes conductance, while µS/cm describes conductivity. This page converts conductance prefixes only and does not apply a cell constant.
Transistor transconductance
The transconductance of a transistor, the change in output current per unit change in input voltage, is measured in siemens. A bipolar transistor biased at 1 mA has a transconductance near 38.7 mS, since it equals collector current divided by the thermal voltage of about 25.85 mV at room temperature. In kS that is 0.0000387, and in µS it is 38,700. Small-signal models use these values to compute gain: a stage with a transconductance of 38.7 mS driving a 5 kΩ load has a voltage gain near 193, since gain is the product of the two when expressed in siemens and ohms. Data sheets list them in mS or µS, and when the numbers go into a simulation it helps to keep one unit. The page converts units and does not model a device.
Conductances in parallel
Conductances add when elements are in parallel. Three paths of 100 S, 250 S and 150 S total 500 S, which is 0.5 kS or 500,000,000 µS. Adding resistances in parallel needs reciprocals, but adding conductances is plain addition, which is why power engineers and circuit solvers often use conductance matrices. When one path is a short with kS-level conductance and another is a leak with µS-level conductance, the leak is negligible: 1 µS added to 500 S changes the total by 0.0000002 percent. The comparison is easier to see in a single unit.
Siemens and seconds in copied tables
Older meter dials and parts lists may label conductance in mho, which is the same size as one siemens. Current data sheets use the siemens. The symbol is S, with a capital letter, and it should not be confused with s for seconds. In SI Brochure notation, kS means kilosiemens, and kS and ks are different symbols. A document that writes ks for kilosiemens is using the symbol for kiloseconds. When you copy a table from a scanned or converted file, check that capital letters survived, because a lost capital S changes the quantity from conductance to time and the value to nonsense.
Conductance shifts with temperature and frequency
The converter changes the unit of a conductance. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not convert resistance to conductance for you. Real conductances depend on temperature, frequency and conditions, and a figure from one test may not apply to another. For decisions that affect safety, use the applicable standard and the judgment of a qualified person.
Cables and busbars in conductance terms
A welding cable run with a total resistance of 5 mΩ has a conductance of 200 S, which is 0.2 kS or 200,000,000 µS. A busbar joint of 0.5 mΩ has 2,000 S, or 2 kS. Electrical models that use nodal analysis build their matrices from conductances, so values in the hundreds or thousands of siemens appear for power paths. Meanwhile, the insulation between the same conductors might be 5 MΩ, a conductance of 0.2 µS, so the two numbers differ by a factor of 1,000,000,000 even though both describe the same system. Writing them in one unit, µS here, shows that the leakage path is a billionth of the conducting path, which is why it can be left out of a load-flow estimate. Small conductances are measured by applying a voltage and reading the current: at 10 V, 0.2 µS passes 2 µA, which an ordinary bench meter reads without trouble. Water in a sample cup shows a similar order of conductance, and its reading changes by about 2 percent per kelvin for dilute salt solutions, so meters compensate to a reference temperature of 25 °C. That compensation belongs to the conductivity meter and its method, and the page supplies only the prefix change.